Cobb County · Código de ordenanzas
Part I - OFFICIAL CODE OF COBB COUNTY, GEORGIA / Chapter 58 - FLOODS / Article II - FLOOD DAMAGE PREVENTION / Division 3 - STANDARDS FOR DEVELOPMENT IN FLOODPLAIN
See. 58-67. Development standards.
Sobre este texto
- As published by Municode, current through 2025-11-20
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
The following development standards shall apply:
(1) All drainage structures and facilities shall be constructed in accordance with county standards and specifications.
a. Donation or dedication of property for water quantity and water quality purposes. The donation or dedication of land (floodplain or non-floodplain) for
stormwater quantity or quality requirements may be accommodated by administrative variance, if so requested by the owner. Any required setbacks or minimum lot sizes affected by the donation or dedication of land (floodplain or nonfloodplain) for stormwater quantity or quality requirements may be administratively varied. The owner shall make the request to the director of the community
development agency and the request shall be processed in accordance with section 134-35, except that the variance may equal up to 100 percent of the existing requirements. The use of administrative variances for the donation or dedication of property for water quantity and water quality purposes shall not allow for an increase development density above that permitted by the underlying zoning. Any administrative variance for the donation or dedication of property for water quantity and water quality purposes shall be reported to the district commissioner.
(2) In districts which permit residential use, not less than 12,500 square feet of a single contiguous area of one zoning classification shall be at least 18 inches above the effective base flood
elevation such that encroachments into the future-conditions "built-out" conditions floodplain for residential structures will not be required. A smaller such area of less than 12,500 square feet but still at least 18 inches above the future-conditions flood elevation may be permitted at the sole discretion of the director upon petition supported by documentation in conformance with subsection 58 68(3).
(3) The location, design, elevation and construction of all public utilities and facilities such as sewer, gas, electrical, and water systems and
streets, shall be in such a manner as to minimize or eliminate damage by flooding. Construction of these facilities on piers shall be permitted. Accesses to utilities shall be above
the base flood elevation. Unless a variance is granted both public and private roadways shall be constructed not less than three feet above the base flood elevation measured at the centerline of the road. Roadways shall not be deemed top include a driveway which services only one residence, structure or property.
(4) Provision shall be made for the adequate control of erosion and sedimentation, in accordance with county sediment control and stormwater management standards, as
amended.
(5) Fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must be certified by a registered professional engineer and must meet or exceed the following minimum criteria; a minimum of two openings having a total area of not less than 100 square inches for every square foot of lateral wall surface area subject to submersion during the baseflood (100-year flood) event, must be provided. At least half of the total required opening area must be provided below the baseflood elevation. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens,
louvers, or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters.
Historia
(Ord. of 10-11-88, art. VI; Code 1977, § 3-14-27; Ord. of 7-10-01; Ord. of 1-22-02; Ord. of 4-13-04; Ord. of 1-24 06; Ord. of 2-27-07)
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.