Atlanta · Ordenanza de zonificación
Atlanta Zoning Ordinance
Este documento se muestra completo, como un solo texto: su fuente no lo divide en secciones.
Sobre este texto
- As published by Municode, current through 2026-10-21
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
- Read by OCR from a scanned page: a character, a name, or a number may be misread.
Este texto se leyó por OCR de una página escaneada: una letra, un nombre o un número pueden estar mal leídos.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Parte 7 de 24. Este texto es largo, así que su página lo muestra en partes, en el orden de la fuente. Un enlace a uno de sus párrafos lleva a la parte que lo contiene.
3. Paving: All sidewalk paving shall be of a type specified in accordance with uniform design standards for placement of such
objects in the public right-of-way. Any existing decorative hardscape treatment of sidewalks, including amenity zone and sidewalk walk zone areas, shall be
retained as part of any new development or replaced with materials that match in size, shape, and color.
4. Street tree planting requirements: Street trees are required and shall be planted in the ground within the amenity zone and
spaced equidistance and on-center between street lights as specified for the applicable street type in Table 5. All
newly planted trees shall be singlestemmed at a minimum of three inches in caliper (measured 36 inches above
ground), shall be a minimum of 12 feet in height at the time of planting and shall be limbed up to a minimum height of
seven feet. Trees shall be planted with a minimum of 40 square feet of evergreen
ground cover such as mondo grass or liriope spicata. All tree plantings, replacement and removal shall be approved by the city arborist.
5. Pedestrian and street lights shall be placed equidistant and on-center between required street trees within the amenity zone as specified for the applicable street type in Table 5.
6. Outdoor dining. Outdoor dining within the required public sidewalk shall:
a. Be allowed to encroach into the walk zone only when the amount of unobstructed sidewalk is provided as specified in the Table 5: SPI-12 Buckhead/Lenox Stations Sidewalk Table;
b. Be prohibited from containing any fixed or attached structure within such walk zone encroachment area;
c. Be separated from the unobstructed walk zone only with movable planters, movable fencing or similar nonfixed barriers provided they do not exceed a height of 42 inches including any plant material; and
d. Comply with all requirement of this chapter at such time as the outdoor dining use is discontinued for more than 30 days.
7. Alternative transportation systems. The location of transit stops for shuttles,
buses or other similar forms of public transportation and paths, trails or similar forms of non-vehicular travel ways shall be coordinated with the Buckhead Area
Transportation Management Association (BATMA). The widths of amenity zones and walk zones may be varied to accommodate such elements.
8. Visibility at intersections. Nothing shall be erected, placed, planted or allowed to grow in such a manner as to impede
visibility within visibility triangles at street intersections, as measured from
the curb, between the heights of two and one-half feet and eight feet above grade.
See section 16-28.008(9) Visibility at Intersections.
9. Overhead utilities. Upon redevelopment of a parcel reasonable efforts shall be
made to place utilities underground or to the rear of structures to allow for
unobstructed use of sidewalks.
10. Peachtree Road parcels. Parcels shall be permitted to credit new street tree planting and sidewalk areas created as a part of the Peachtree Corridor Project towards any required street tree planting and
sidewalk requirements and any required open space requirements.
11. In recognition of the existing mature tree canopy, landscaping and topography
located between the back of curb and the buildings on Piedmont Road in Subarea
4, properties in Subarea 4 shall be exempt from compliance with Section
16-18L.009(1) through Section 16-18L.009(5) and Table 5: SPI-12 Buckhead/Lenox Stations Sidewalk Table on Piedmont Road unless the mature tree
canopy and landscaped area on the applicable property is redeveloped. To the extent the exemption in this Section 16-18L.009(11) is utilized, the applicable property shall retain the existing five
foot walk zone located at back of curb on Piedmont Road and provide a separate
eight foot multi-use path between the building and the back of curb on Piedmont Road.
_______________________________________________________________________________________________
TABLE 5: SPI-12
BUCKHEAD/LENOX
STATIONS
SIDEWALK
TABLE
AMENITY
ZONE
MINIMUM
WALK
ZONE
MINIMUM
UNOBSTRUCTED
WALK ZONE
WITH DINING
ENCROACHMENT
MINIMUM
STREET
TREE
SPACING
MAXIMUM
STREET
LIGHT
SPACING
MAXIMUM
Peachtree Road, width (feet) 5' 15' 10' 40' 80'
TABLE 5: SPI-12
BUCKHEAD/LENOX
STATIONS
SIDEWALK
TABLE
AMENITY
ZONE
MINIMUM
WALK
ZONE
MINIMUM
UNOBSTRUCTED
WALK ZONE
WITH DINING
ENCROACHMENT
MINIMUM
STREET
TREE
SPACING
MAXIMUM
STREET
LIGHT
SPACING
MAXIMUM
Primary and local streets, width (feet) 5' 10' 6' 30' 60' Private streets that function as a public street for determining block area per section 16-18L.015(3)(b), width (feet) Not Required 6' 6' Not Required Not Required (Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2020-53(20-O-1323), § 9, 10-14-20) _______________________________________________________________________________________________ Sec. 16-18L.010. Supplemental zone.
Supplemental zones shall meet the dimensions identified in Table 6: SPI- 12 Buckhead/ Lenox Stations Supplemental Zone Table, and shall meet the following requirements.
1. Elevation and grade. The supplemental zone (including any porches and stoops
associated with residential uses) shall have a maximum elevation of 36 inches above finished sidewalk grade unless existing topographical considerations render this requirement unreasonable in the determination of the director.
2. Storefront windows. Storefront display windows may project into the required
supplemental zone but shall not cover more than two-thirds of its horizontal area and shall have a minimum depth of three feet, to be internally illuminated, serviced by electricity, and accessible from the interior of a building.
3. Additional requirements for supplemental zones.
a. Adjacent to all uses: Shall provide a pedestrian walkway a minimum
width of four feet through said supplemental zone to connect to the adjacent required sidewalk. Said walkway shall be predominantly perpendicular to the street unless topography prohibits.
b. Adjacent to sidewalk-level nonresidential uses: Shall be hardscape for pedestrians to access a minimum
of 75 percent of its area excluding fountains, pools, pedestrian furniture, public art, outdoor dining and similar elements. See section 16-18L.008 when utilizing supplemental zones as part of open space calculations.
c. Adjacent to sidewalk-level residential units:
i. Said zone shall be a minimum of 25 percent landscaped except when located on Peachtree Road which shall have no minimum requirement.
ii. Buildings with more than four sidewalk-level residential units shall be permitted to share said required pedestrian walkway with one adjacent unit.
4. Fences and walls. Fences and walls shall only be allowed within the supplemental zone when meeting the following regulations.
a. For all sidewalk-level residential and outdoor dining uses:
i. Walls shall not exceed 42 inches in height unless existing topography requires a retaining wall of greater height;
ii. Fences shall not exceed 42 inches in height; and iii. Any railings, balustrades, or enclosures around stoops, stairs, or porches shall be a minimum of 60 percent open,
b. For all other non-residential sidewalk-level uses: Fences and walls are prohibited.
c. Retaining walls shall be finished poured concrete or shall be faced with stone, brick or smooth stucco and shall be architecturally compatible with the adjacent building's design.
5. Cantilevered portions of buildings. A building may cantilever over the supplemental zone, provided there is a minimum vertical clearance of 24 feet above the finished supplemental zone grade.
6. Outdoor dining. Outdoor dining locations shall be designated within the approved SAP as available for such use
and no encroachment by outdoor dining outside an area so designated shall be permitted.
7. In recognition of the existing mature tree canopy, landscaping and topography
located between the back of curb and the buildings on Piedmont Road in Subarea
4, properties in Subarea 4 shall be exempt from compliance with Section
16-18L.010(1) through (3) and Table 6:
SPI-12 Buckhead/Lenox Stations Supplemental Zone Table on Piedmont Road unless the mature tree canopy and landscaped area on the applicable property is redeveloped.
_______________________________________________________________________________________________
TABLE 6: SPI-12
BUCKHEAD/LENOX STATIONS
SUPPLEMENTAL ZONE TABLE
SUPPLEMENTAL
ZONES
(those not designated as plaza areas) Minimum/Maximum
SUPPLEMENTAL
ZONES
(those designated as plaza areas) Minimum/Maximum Peachtree Road, width (feet) 15'/25' 35'/No maximum Primary streets, width (feet) 10'/25' 30'/No maximum Local streets, width (feet) No minimum/25' 30'/No maximum (Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2020-53(20-O-1323), § 10, 10-14-20) _______________________________________________________________________________________________ Sec. 16-18L.011. Relationship of building to street.
Regulations contained in this section apply to all buildings and structures, including parking structures, except structures for parking lot attendants that are less than 50 square feet.
1. General sidewalk-level building façade requirements.
a. All buildings shall have a minimum of one building façade meeting the major sidewalk-level building façade requirements of this section. All other building façades shall be considered as minor sidewalk-level building façades.
b. For parcels with more than one street frontage, major sidewalklevel building façades shall be required according to Table 7: SPI-12
Buckhead/Lenox Stations Primary Sidewalk-Level Building Façades Hierarchy Table. Only one street shall be required to meet the major sidewalk-level façade requirements, with the street with the table's highest assigned ranking being considered the major sidewalklevel. In this way, streets with an order of priority of "1" shall have a
higher priority over streets with an order of priority of "2", and so on. If there are multiple streets with the same highest ranking the SAP applicant shall choose their defined major sidewalk-level designation.
c. Wherever the term sidewalk-level is used elsewhere in this chapter, without further delineation between major or secondary status, it shall apply to both major and minor sidewalk-level building façades.
d. Active uses, where provided, shall be serviced by plumbing, heating, and electricity and are limited to the residential uses and nonresidential uses designated in Table 1: SPI-12 Buckhead/Lenox Stations
Use Table, with the exception of the following non-residential uses which shall be prohibited:
i. Helicopter landing facilities or pick-up or delivery stations;
ii. Parking structures; and iii. Structures required for public transit.
2. Major sidewalk-level building façades.
Major sidewalk-level building façades shall meet the following requirements:
a. Major sidewalk-level fenestration and building massing.
i. Building façades greater than 100 continuous feet in horizontal length shall include variety in façade treatment such as materials, textures, colors and/or window and door patterns.
ii. The length of façade without intervening fenestration or entryways shall not exceed 20 feet.
iii. Fenestration shall be provided for the horizontal length of the primary sidewalk-level façade as listed below for the following street types:
a. Peachtree Road and primary streets: A minimum of 65 percent.
b. All other streets (including pedestrian ways): A minimum of 50 percent.
b. Major sidewalk-level entrances.
i. Buildings with more than four residential units which are located at the major sidewalklevel, except those with either supportive housing, nursing
homes, personal care homes or assisted living uses, shall have individual entrances to such units directly accessible from the public sidewalk and shall open directly onto the adjacent public sidewalk, supplemental zone, terrace, porch, plaza, or park adjacent to the public sidewalk. Said buildings shall have porches, stoops or wheelchair access at each sidewalk-level entrance.
ii. All residential uses located above or below the major sidewalk-level shall provide major sidewalk-level access via a lobby or a similar space.
c. Major sidewalk-level active uses.
i. Active uses shall be provided within buildings and parking structures for the entire length of said building façade except ingress and egress points into parking structures or loading areas.
ii. Minimum sidewalk-level floor to ceiling height for primary sidewalk-levels fronting Peachtree Road and primary streets shall be 18 feet, as measured vertically from the ground floor to the structural ceiling, not including drop ceilings or other interior ceiling treatments within the sidewalklevel floor space.
3. Minor sidewalk-level building façades.
Minor sidewalk-level building façades shall meet the following requirements:
a. Minor sidewalk-level fenestration.
Fenestration shall be provided for the horizontal length of the minor sidewalk-level façade as listed below for the following street types:
i. Primary streets: The requirements for major sidewalk-levels shall apply when sidewalklevel building façades are located along such streets.
ii. All other streets (including pedestrian ways): A minimum of 25 percent. Artistic wall murals, architectural treatments and other forms of building articulation that do not utilize glass shall be permitted
to account for a maximum of 50 percent of this requirement.
b. Minor sidewalk-level entrances.
Entrances shall only be required when active uses are provided and no other entrance is provided along another façade.
c. Minor sidewalk-level active uses.
Active uses shall not be required.
4. Additional fenestration provisions. Where sidewalk-level fenestration is required, the following additional provisions shall apply:
a. Windows and door glass shall utilize clear glass or tinted glass. Tinted glass shall have a transmittance factor of 50 percent or greater and shall have a visible light reflectance factor of ten or less. Painted glass, reflective glass or other similarly treated or opaque windows are not permitted.
b. Fenestration for display windows or cases shall allow visibility into the window or case for a minimum depth of 18 inches, measured from the interior windowpane.
c. Fenestration for all other nonresidential storefront windows shall allow visibility into the building for
a minimum depth of ten feet when located along Peachtree Road and primary streets, and five feet along all other streets, measured from the interior windowpane and shall be internally illuminated.
d. Façade treatment measurement.
Fenestration and entrances shall be provided as measured beginning at a point not more than 36 inches above the required public sidewalk to a height at least ten feet above said sidewalk, with the following exceptions:
i. When the finished floor elevation is 36 or more inches above the public sidewalk, height
shall be measured beginning at the finished floor elevation to a height at least ten feet above the finished floor elevation; or ii. When the finished floor elevation is below said sidewalk, height shall be measured beginning at a point not higher than the adjacent public sidewalk to
a height at least ten feet above the finished floor elevation.
5. Additional pedestrian entrance provisions. Where sidewalk-level pedestrian entrances are required, the following
additional provisions shall apply:
a. Entrances shall be architecturally articulated, and face, be visible from, and be directly accessible from the adjacent public sidewalk. The use of fire-escape, entrance-only and exitonly doors as primary entrances is prohibited.
b. Lobby doors and similar entrances may be recessed a maximum depth of ten feet and may have a maximum width of 20 feet. All other doors may be recessed a maximum depth of five feet.
c. Entrances for non-residential uses shall remain unlocked during busi- ness hours and shall be at-grade with the closest portion of the adjacent required public sidewalk.
d. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit. This provision shall not apply to single-family and two-family residential
structures.
6. Additional active use provisions. Where sidewalk-level active uses are required, the following additional provisions shall apply:
a. Sidewalk-level active uses shall not include parking, non-residential storage areas, driveways, or queuing lanes parallel to the adjacent street.
b. Active uses shall be provided for a minimum depth of 20 feet, as measured from the sidewalk-level building façade.
7. Specific uses in enclosed buildings. The following uses shall be placed within a
building or parking structure and subject to the active-use requirement of this
section, except at ingress and egress points.
a. Structures and features associated with fueling stations such as accessory fueling pumps, air pumps, repair garages, vehicular service areas and
car washes, when within 300 feet of Peachtree Road or any primary street.
b. Drive-through service windows for any use, including structures and associated queuing, when within 300 feet of Peachtree Road or any primary street.
c. Sales and leasing agencies for new and used passenger automobiles and commercial vehicles. Such uses shall only be permitted within mixed-use buildings and shall not constitute the primary use of the building.
8. Address. A street address number shall be clearly visible from the public sidewalk, and shall have a minimum height of six
inches.
9. Up-lighting. All up-lighting shall be located a minimum height of eight feet
above the required public sidewalk, driveway or supplemental zone.
10. External storefront security grilles, gates and security doors.
a. Shall be fully retractable during business hours and shall permit visibility into the interior of protected space when in use;
b. Opaque systems are prohibited;
c. External housing and shields for such systems shall be painted the same color as the frames of the storefront system they protect; and
d. Vehicular gates and doors may be recessed a maximum depth of 20 feet.
11. In recognition of the existing mature tree canopy, landscaping and topography
located between the back of curb and the buildings on Piedmont Road in Subarea
4, properties in Subarea 4 shall be exempt from compliance with Section
16-18L.011(2)(b) (major sidewalk-level entrances), Section 16-18L.011(2)(c) (major sidewalk-level active uses), Section
16-18L.011(8) (address) and Section 16-18L.011(9) (up-lighting) on Piedmont Road unless the mature tree canopy and landscaped area on the applicable property is redeveloped.
_______________________________________________________________________________________________
TABLE 7: SPI-12 BUCKHEAD/LENOX
STATIONS PRIMARY SIDEWALK-LEVEL
BUILDING FAÇADES HIERARCHY TABLE ORDER OF PRIORITY Peachtree Road 1
Primary streets 2 aLocal streets and private streets that function as local streets 3 aPedestrian ways 4
INDEX/FOOTNOTES
a Georgia State Route 400, the MARTA northern concourse pedestrian bridge and the SPI-12 district boundary shall not be considered streets for purposes of the sidewalk-level building façade requirements of the section.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2020-53(20-O-1323), § 11, 10-14-20;
Ord. No. 2026-05(26-O-1001), § 7, 2-25-26) _______________________________________________________________________________________________ Sec. 16-18L.012. Dumpsters, loading, loading areas and entrances, mechanical and accessory
features, and fences and walls.
1. The off-street loading requirements for this district are as shown in the table of loading requirements, section 16-28.015, off-street loading requirements.
2. Dumpsters, trash compactors, loading areas and loading docks shall be located and oriented in a manner to minimize visibility from public rights-of-way or walk zones. If such elements are otherwise visible screening via either opaque walls, gates or landscaping shall be provided so such elements would not be visible. In addition, all external dumpsters and trash compactors shall be enclosed with opaque walls a minimum of eight feet in height.
3. Building mechanical and accessory features (including satellite dishes):
a. Shall be located to the side, rear, or roof of the principal structure and within
each such location shall be in the location of least visibility from any public park, plaza, public right-of-way, private street, required sidewalk, or sidewalk-level
outdoor dining area and are prohibited between the building and any public street. When not located in an area of least visibility, said mechanical and accessory features shall be screened.
b. When located on rooftops shall be incorporated in the design of the building and screened with materials similar to
the building.
4. Fences and walls:
a. No barbed wire, razor wire, chain link or similar elements shall be visible from
any public park, plaza, public right-ofway, private street, pedestrian way, required sidewalk or sidewalk-level
outdoor dining area.
b. Fences and walls are prohibited between a pedestrian way and a lot line.
c. For all locations not located between the building and the required sidewalk: the
maximum height of all fences and walls shall be eight feet.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2019-09(18-O-1581), § 4.D, 1-31-19)
Sec. 16-18L.013. Signs.
See section 16-28A.010(13) for SPI-12 Sign Regulations.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12)
Sec. 16-18L.014. Driveway curb cuts, driveways, parking facilities.
1. Driveways and curb cuts.
a. For all uses except for hotels, driveways shall be predominantly perpendicular to
any adjacent street and are not permitted between the required sidewalk and the adjacent building except to reach the side yard, rear yard or an on-site parking facility.
b. Notwithstanding the provisions of section 16-28.006(10), independent driveways are not required when access is provided by a common or joint driveway for adjacent lots that have direct vehicular access to a street, or a driveway from a private
street which functions as a public street.
Said shared arrangement may be authorized by the director of the office of planning, based on traffic considerations, when a perpetual easement agreement is
agreed upon by all affected property owners and a copy of such agreement is filed with the office of planning.
2. Street types.
a. Streets, private streets and private drives intersecting with Peachtree Road or
primary streets:
i. Shall be designed to have the appearance of public streets and shall meet the requirements of sections
16-18L,009, 16-18L.010 and 16-18L.011 for a minimum distance of 50 feet from the Peachtree Road or primary street entryway, as measured along the center-line of the street or drive; provided, however, in recognition of the existing mature tree canopy, landscaping and topography located between the back of curb and the buildings on Piedmont Road in Subarea 4, properties in Subarea 4 shall be exempt from compliance with this Section
16-18L.014(2)(i) unless the mature tree canopy and landscaped area on the applicable property is redeveloped; and ii. Shall have no limit of total curb cut width(s) along Peachtree Road or
primary streets.
b. Streets, private streets and private drives intersecting with all other street types:
i. Curb cuts accessing parking areas shall have a maximum combined width of 36 feet per street, private street or private drive; and ii. Curb cuts accessing loading areas shall have a maximum width of 14 feet per curb cut. The number of such curb cuts shall not exceed the number of required loading spaces designated in Table 8: SPI -12 Buckhead/Lenox Stations Loading Table.
Loading area curb cuts are permissible per building, not per street, and may be combined; and
iii. The total number and total width of curb cuts accessing parking areas
and loading areas may be increased when documentation is provided from a certified traffic engineer proving the need for the increased number and/or dimensions. Developments granted such increases shall meet the Transportation Management Plan requirements of section 16-18L.018 regardless of the total
square footage of the development.
3. Sidewalks. All sidewalk paving materials and widths shall be continued across any intervening driveway curb cut at the prevailing grade and cross slope as the adjacent sidewalk walk zone. Bands of textured concrete shall also be installed which are:
a. Adjacent to the street and of equal width and alignment to the amenity zone; and
b. Adjacent to the back of the required walk zone and in-line with the supplemental
zone at a minimum width of five feet.
4. Parking structures.
a. In addition to section 16-28.028, parking structures shall meet the sidewalk-level building façades requirements as
applicable in section 16-18L.011.
b. A minimum of one (1) entrance to parking structures shall have a minimum height of 90 inches for the ingress and
egress of vanpool vehicles.
5. Lighting. All parking facility lighting shall reduce light spillage onto adjacent properties by providing cutoff luminaries which have a maximum 90 degree illumination.
6. Maintenance. Parking spaces and driving lanes shall be clearly defined and maintained as such. See section 16-28.026 for additional requirements.
7. Landscaping. The requirements of City of Atlanta Code of Ordinances section 158-30 including related cross-references thereto shall apply.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2020-53(20-O-1323), § 12, 10-14- 20)
Sec. 16-18L.015. Connectivity and block standards.
1. Block connectivity. New development in Subareas 1, 2 and 3 proposing to contain a continuous block face greater than 600 feet in length without an intervening street or a private street that functions as a public street meeting the requirements of section 16-18L.014(2) shall be traversed by streets which create block faces no more than 400 feet in length along a public street.
2. Pedestrian ways utilized to satisfy block connectivity or block area regulations shall:
a. Provide a continuous minimum total width of 45 feet which shall be unobstructed up to a minimum vertical clearance of 18
feet except for any structural columns.
Also, within any such pedestrian way is a minimum 15 feet wide continuous
pedestrian path(s) which is unobstructed by any vertical or overhead elements
that is required in lieu of the sidewalk walk zone requirements in section
16-18L.009;
b. Provide pedestrian directional signage for the pedestrian way when the
pedestrian way intersects with public streets or private streets that function as public streets.
3. Any buildings adjacent to such a pedestrian way, whether located on-site or off-site, shall meet the requirements for relationship of building to street in section 16-18L.011. Newly created streets. Newly created public streets and private streets that function as a public street, which are utilized to satisfy block connectivity or block area regulations, shall meet the following regulations:
a. Provide such street types at a minimum distance of 100 feet from any other
predominantly parallel street; and
b. All such street types shall meet the requirements of section 16-18L.014(2) except that private streets that function as a public street shall be permitted to utilize the following standards in lieu of the section 16-18L.014(2) regulations for a maximum of 40 percent of the permissible street types for determining block area:
i. An amenity zone and a supplemental zone shall not be required; and ii. A minimum walk zone of six feet shall be provided on one side of the private street.
4. Removal of private connectivity. The following provisions shall apply when private streets that function as a public street are utilized to satisfy block area calculations for any property within the district and are later removed or altered in part or in whole.
a. A SAP from the director shall be required.
Such SAP shall demonstrate that district access and connectivity will be provided to an equivalent or greater degree than
provided prior to the removal of such elements.
b. Such removals or alterations shall not result in a reduction in height calculations and shall not be deemed nonconforming, per section 16-18L.007(3)(b)(ii).
5. Restricted connections and intersections.
The following provisions shall apply to streets which are unable to connect to or intersect with another street for purposes of meeting any related requirements of this district due to topographic or other physical restrictions.
a. Such streets shall be permitted to be considered as connecting to or intersecting with other streets when:
i. Located a maximum distance of 25 feet apart; and ii. Documentation of the topographic or physical features that prohibit the connection or intersection of such streets is provided.
b. For purposes of quantifying district block area calculations, these areas shall be
quantified by determining the total linear distance between the non-connecting or
non-intersecting streets.
6. Old Ivy Road access. In Subarea 4, vehicular access to Old Ivy Road shall be designed to prohibit vehicles from turning right out onto Old Ivy Road or turning left in from Old Ivy Road.
Signage prohibiting the right out and left in movements shall be posted at the intersection with Old Ivy Road. Vehicular access from Old Ivy Road shall be closed with a physical barrier from 7:00 pm to 7:00 am daily and at all times on the weekend. In the event of significant or repeated illegal turns into or out of the Old Ivy Road curb cut, the owner shall provide, at the discretion of the City of Atlanta Office of Transportation, at the owner's expense, an offduty City of Atlanta police offier to direct traffic movements between 7:30 am to 9 am and 5:00 pm to 6:30 pm each weekday.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2020-53(20-O-1323), §§ 13, 14, 10-14-20)
Sec. 16-18L.016. Off-street parking requirements.
Off-street parking for all uses shall be provided in accordance with the Table 9: SPI-12 Buckhead/ Lenox Stations Parking Table and subject to the subsections below. See also sections 16-28.013 and 16-28.014.
1. Minimum parking. There shall be no minimum off-street parking required except that uses with alcohol beverage licenses shall be required to meet the minimum parking requirements set forth in Chapter 10 of the Code of Ordinances (Alcoholic Beverages).
2. Maximum parking. Unless otherwise shown in Table 9: SPI-12 Buckhead/ Lenox Stations Parking Table, the maximum allowable off-street parking shall be one space for each 200 square feet of floor area.
3. Location. With the exception of regional shopping centers, accessory off-street
surface parking lots shall not be located between a building and an adjacent street without an intervening building.
4. Screening. Off-street surface parking lots shall be screened from adjacent streets
and sidewalks. Only perpendicular driveway crossings and delineated pedestrian paths shall be allowed through such screening. Screening shall
incorporate screen wall extensions, berms, and/or vegetative fences or screening
between the parking lot and the sidewalk(s) at a minimum height of 36 inches. The following additional screening controls shall apply:
a. Berms, vegetative fences or screening shall have a maximum height of 42 inches.
b. Screen wall extensions shall:
i. Be located predominantly parallel and congruent with the adjacent building façade;
ii. Be a maximum height of 12 feet; and iii. Be a minimum of 50 percent permeable or articulated to avoid blank walls.
5. Shared or transferred off-street parking requirements.
a. Parking allocations for uses not involving alcohol beverage licenses may be shared or transferred offsite at the discretion of the director.
b. Parking allocations for uses with alcohol beverage licenses may be shared or transferred off-site at the discretion of the director upon a written determination that the applicant has established a valid shared or off-site parking arrangement which:
i. Meets all other criteria of section 16.25.002(3);
ii. Provides safe and permissible pedestrian circulation and access between the principal structure and off-site parking facilities at no more than 1,000 feet in horizontal walking distance as measured along areas dedicated to or permitted for pedestrian access;
iii. Shows that all shared or offsite parking spaces will be clearly marked and signed as
reserved during specified hours;
and iv. Documentation include the following:
(1) A map drawn to scale that indicates the location of proposed parking spaces;
and
(2) Copies of valid shared parking agreements.
Renewed agreements shall be filed with the office of planning.
6. Office uses, additional requirements. Any development providing more than 50,000
square feet of gross office space shall reserve and designate carpool and vanpool parking spaces with notification of such spaces to be provided to the Buckhead Area Transportation Management Association (BATMA) at the minimum
ratios as follows:
i. Three percent of all parking spaces as "carpool only", but shall not be required to exceed seven such spaces, with a minimum of one such space to provide electrical conduit and infrastructure to encourage future access for electric vehicles.
ii. Two percent of all parking spaces as "vanpool only", but shall not be
required to exceed three such spaces.
7. Transit station area. Within the transit station area, off-street parking spaces
shall be permitted to be reserved and designated as "transit access only" parking. The allocation of such spaces shall be permitted without limit and shall be
coordinated with the Buckhead Area Transportation Management Association
(BATMA).
_______________________________________________________________________________________________
TABLE 9: SPI-12 BUCKHEAD/LENOX
STATIONS PARKING TABLE MAXIMUM ALLOWABLE PARKING SPACES Child care centers, kindergartens and other special schools
One space per 600 square feet of floor area; In addition to providing off-street parking, such establishments shall provide safe and convenient facilities for loading and unloading children, approved by the department of transportation
Commercial recreation establishments, including bowling alleys, theaters, convention halls, places of assembly, and similar uses, with primary activities conducted within fully enclosed buildings One space for each 100 square feet of floor area Drive-in, drive-through establishments See section 16-28.021 Tailoring, custom dressmaking, millinery and similar establishments
One space for each 300 square feet of floor area Eating and drinking establishments—Indoor dining and covered outdoor dining
One space for each 200 square feet of floor area for uses without alcoholic beverage license; One space for each 100 square feet of floor area for uses with alcoholic beverage licenses
TABLE 9: SPI-12 BUCKHEAD/LENOX
STATIONS PARKING TABLE MAXIMUM ALLOWABLE PARKING SPACES Eating and drinking establishments—Indoor dining and covered outdoor dining
One space for each 200 square feet of floor area for uses without alcoholic beverage license; One space for each 100 square feet of floor area for uses with alcoholic beverage licenses
Eating and drinking establishments—Uncovered outdoor dining
If outdoor uncovered dining space is greater than 25 percent of the total gross floor area of the establishment, it shall provide a maximum of one additional space per 600 square feet for such accessory outdoor dining area
Hotels One space per rental unit plus one-half space per employee and one space per 100 square feet of restaurant/lounge gross leasable area and one space per 300 square feet of other convention facilities Nursing homes One space for each four beds Office uses Two and one-half spaces for each 1,000 square feet of floor area
Parking structures (as a primary use) No parking requirement Personal care homes, assisted living facilities, continuing care retirement communities and rehabilitation centers with a residential component
See section 16-08.007 for applicable ratios according to the appropriate floor area ratio
Other recreation and entertainment uses One space for each 400 square feet of floor area Single-family dwellings, multi-family dwellings and supportive housing
Two spaces per unit plus one-half space for each unit with three or more bedrooms + one-third space per unit for guest parking
Retail establishments One space for each 200 square feet of floor area Public and private schools and institutions of higher learning, including colleges and universities One space for each four fixed seats (with 18 inches of bench length counted as one seat); or One space for each 35 square feet of enclosed floor area for the accommodation of movable seats in the largest assembly room, whichever is greater, plus the following:
i. For elementary or middle schools: Two spaces for each classroom;
ii. For high schools: Four spaces for each classroom;
iii. For colleges and universities: Eight spaces for each classroom
Accessory uses One space for each 300 square feet of floor area All other uses One space for each 200 square feet of floor area (Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2020-33(20-O-1381), § 25, 6-23-20) Sec. 16-18L.017. Minimum bicycle parking.
See section 16-28.014(6), Bicycle parking requirements.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2019-09(18-O-1581), § 12, 1-31- 19)
Sec. 16-18L.018. Transportation management plans.
The office of buildings shall not issue any certificate of occupancy permits for any multifamily residential, office, or hotel development (including the sum of such uses in combination) having more than 25,000 square feet of gross floor area until such time the developer or their specified agent has submitted to the office of zoning a transportation management plan (TMP).
This TMP shall contain strategies to reduce single occupancy vehicle trips generated by the project and shall be in accordance with the transportation management plant development guide, a document maintained by the Atlanta Department of Transportation.
Upon the face of the permit plans for improvement of real property subject to the TMP requirement, the applicant shall acknowledge by signature, for itself and successors and assigns on the permit plans, that it will satisfy the requirements of 16-18L.018 and certify which strategies will be used to reduce single occupancy vehicle trips.
A summary report of ongoing implementation of the TMP shall be submitted annually.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12; Ord. No. 2021-10(20-O-1723), § 3, 3-10- 21)
Sec. 16-18L.019. Roofs, bridges and tunnels.
1. Roof surface. A minimum of 75 percent of roof surface that covers floor area and is not used for roof penetrations or on-site renewable energy power systems shall achieve a minimum initial Solar SRI of 78 for a low-sloped roof (less than or equal to 2:12) and a minimum initial SRI of 29 for a steep-sloped roof (more than 2:12).
2. Pedestrian bridges and tunnels and privately owned vehicular bridges and tunnels are
prohibited when located above or below public streets, with the exception of tunnels for service and loading purposes.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12)
Sec. 16-18L.020. Incentivized developments.
1. General. Development bonuses specified in this section shall be permitted for any development that meets the listed criteria for plaza areas or green development. However, no
additional building height is permitted unless meeting all of the respective criteria for such plaza areas or green development as indicated below.
2. Plaza areas.
a. Location. Plaza areas eligible for the bonus provisions of this section are limited to one such location for each eligible
plaza area delineated on Map Attachment "D" the SPI-12 Buckhead/Lenox Stations lncentivized Plazas Map.
b. Plaza areas as supplemental zones.
i. Shall be designed and located in accordance with the requirements for supplemental zones in section 16-18L.010.
ii. Shall have an overall scale and layout that delineates such areas as being unlike from the adjacent sidewalk areas.
iii. Shall front the primary sidewalklevel façade of at least one building.
iv. Shall be provided in addition to the total square footage of supplemental
zones that would otherwise be required in the Table 6: SPI-12 Buckhead/Lenox Stations Supplemental Zone Table.
c. Size and incentives.
i. Plaza areas at a minimum size of 2,500 square feet. For such plaza areas, all open space calculations shall be fully satisfied in the required supplemental zones and Plaza area.
ii. Plaza areas at a minimum size of 5,000 square feet. In addition to the above plaza bonus for open space, for such plaza areas an additional building height of 50 feet shall be permitted in excess of the total building height as regulated in section 16-I8L.007(3)(e)(i) for portions of
buildings which meet the following criteria:
(1) Located within 800 feet of the plaza area as measured along a walkable path;
(2) Immediately adjacent to the plaza area with no public streets separating them.
3. Green development.
a. To qualify for the green development incentives, such development shall:
i. Be in excess of 100,000 square feet of floor area;
ii. Utilize non-potable water sources for 100 percent of all outdoor water use;
iii. Provide verification of an Analysis of the City Energy Code that
demonstrates ten percent reduction of energy use, in comparison to the City Energy Code requirements;
iv. Provide open space at least ten percent above open space requirements;
v. Provide a minimum of three electric vehicle charging stations.
b. Developments meeting all of the above criteria shall be entitled to either of the following opportunities:
i. An additional building height of 30 feet shall he permitted in excess of the total building height as regulated in section 16-18L.007(3)(e)(i).
ii. An expedited permitting process when in accordance with a formal "expedited permit program" as established by the office of buildings.
(Ord. No. 2012-23(12-O-0228), § 1(Attach. A), 5-30-12)
(Ord. No. 2012-23(12-O-0228), § 3, 5-30-12)
MAP ATTACHMENT ASPI-12 BUCKHEAD/LENOX STATIONS DISTRICT
STREET BOUNDARIES MAP
(Ord. No. 2012-23(12-O-0228), § 5, 5-30-12)
MAP ATTACHMENT BSPI-12 BUCKHEAD/LENOX STATIONS DISTRICT
STREET FRAMEWORK MAP
(Ord. No. 2012-23(12-O-0228), § 5, 5-30-12)
MAP ATTACHMENT CSPI-12 BUCKHEAD/LENOX STATIONS DISTRICT
HEIGHT FRAMEWORK MAP
(Ord. No. 2012-23(12-O-0228), § 5, 5-30-12)
MAP ATTACHMENT DSPI-12 BUCKHEAD/LENOX STATIONS DISTRICT
INCENTIVIED PLAZAS MAP
(Ord. No. 2012-23(12-O-0228), § 6, 5-30-12)
EXHIBIT X SPI-12 BUCKHEAD/LENOX STATIONS DISTRICT
BLOCK AREA MAP
CHAPTER 18M. RESERVED*
CHAPTER 18N. SPI-14 BERKELEY PARK
DISTRICT REGULATIONS
Sec. 16-18N.001. Scope of provision.
The regulations set forth in this chapter, or set forth elsewhere in this part, when referred to in this chapter, are the regulations in the SPI-14 Berkeley Park District.
(Ord. No. 2001-35, § 1, 7-26-00) Sec. 16-18N.002. Statement of intent.
The intent of this chapter is establishing the SPI-14 Berkeley Park District is as follows:
(1) To preserve and protect the Berkeley Park neighborhood from overcrowding
with all of its accompanying negative impacts, such as excessive noise and traffic, due to the rental of housing units to large groups of unrelated individuals.
(2) To modify the definition of family (section 16-29.001(10)(b) of the 1982 City of Atlanta Zoning Ordinance) within the
areas so designated on the attached map identified as Exhibit B*.
(Ord. No. 2001-35, § 1, 7-26-00) Sec. 16-18N.003. Regulations.
The definition of family (section 16-29.001(10)(b) of the 1982 City of Atlanta Zoning Ordinance) is hereby modified as follows for the area so designated on the attached map identified as Exhibit B*:
(b) Family: One or more persons occupying, a single dwelling or lodging unit, provided that, unless all members are related by
blood, marriage or adoption, no such family shall contain over three persons, with the following exception: Domestic
servants employed on the premises may be housed on the premises without being counted as a family. The term family shall not be construed to mean fraternity, sorority, club, student center, group care homes, foster homes, and similar uses.
(Ord. No. 2001-35, § 1, 7-26-00; Ord. No. 2001- 73, § 1, 10-10-01)
CHAPTER 18O. SPI 15 LINDBERGH
TRANSIT STATION AREA SPECIAL
PUBLIC INTEREST DISTRICT
REGULATIONS
Sec. 16-18O.001. Scope of provisions.
The regulations set forth in this chapter, or set forth elsewhere in this part when referred to in this chapter, are the regulations for the SPI-15 Lindbergh Transit Station Area Special Public Interest District. These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in section 16-18O.003, except that all existing categories of historic protection designated pursuant to chapter 20 of Part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this chapter. Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. Whenever the following regulations conflict with provisions of Part 16 other than historic protection regulations, the more stringent regulation shall apply.
The regulations set forth in sections 16-18O.001 through and including section 16-18O.027 shall apply to all properties located within the SPI-15 Lindbergh Transit Station Area Special Public Interest District, including all subareas within the district. The remaining regulations shall apply only to the subareas identified therein.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.002. Statement of intent.
The intent of the council in establishing SPI-15 Lindbergh Transit Station Area Special Public Interest District as a zoning district is as follows:
1. Create a diversified urban environment where people can live, work, meet and
recreate;
2. Enhance and protect the Lindbergh Transit Station area as a model for retrofitting an existing automobileoriented commercial strip into a transit and pedestrian oriented mixed-use and
multi-family urban neighborhood;
3. Improve the visual aesthetics of the streets and the area;
4. Provide for a pedestrian-oriented environment on streets and sidewalks;
5. Maximize access to transit;
6. Encourage use of transit infrastructure;
7. Encourage a compatible mixture of residential, commercial, and cultural and recreational uses;
8. Provide parking in an unobtrusive manner;
9. Reduce parking requirements by encouraging shared parking and alternative modes of transportation;
10. Encourage a sense of activity and liveliness along the street level of building façades;
11. Encourage a grid of connected streets to improve access and reduce congestion;
12. Provide sufficient, safe and accessible open space for active and passive enjoyment by residents and workers;
13. Facilitate safe and convenient pedestrian and bicycle circulation and minimize
conflict between pedestrians and vehicles;
and
14. Reduce vehicular congestion by encouraging a smooth uninterrupted flow of traffic.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.003. Boundaries of district established.
The boundaries of the SPI-15 Lindbergh Transit Station Area Special Public Interest District are shown on maps Attachment B* which by this reference is incorporated into and made a part of this chapter and this part. The Lindbergh Transit Station Area Special Public Interest District is divided into eight subareas as shown on said maps Attachment B* and are described as follows:
Commercial subareas:
Subarea 1—Miami Circle Commercial Subarea 2—Sydney Marcus Commercial Subarea 3—Piedmont Commercial Subarea 4—Garson Commercial Subarea 9—MARTA Lindbergh City Center Residential subareas:
Subarea 5—Sydney Marcus West Residential Subarea 6—Sydney Marcus East Residential Subarea 7—Garson Residential
Subarea 8—Lindbergh Residential (Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 15(18-O-1702), § 2, 2-13-19)
Sec. 16-18O.004. Application procedures.
A special administrative permit shall be required for development in this district as set forth in this section. A special administrative permit (SAP) application and four copies each of a site plan, landscape plan and elevation drawings of each exterior façade shall be submitted and approved by the director of the bureau of planning prior to the applicant filing for a building permit. All new construction, including additions to existing buildings, expansions of existing outdoor dining, outdoor dining within required sidewalk areas, or any construction which results in increased lot coverage or a modification of the building footprint within this district, shall be subject to said site plan review and approval.
Before making application for a special administrative permit, a pre-application conference between the applicant and the director of the bureau of planning or the director's designee is required to discuss the application and relevant requirements of these regulations. Said preapZONING § 16-18O.004 plication conference shall be held within 14 days of the request by the applicant, unless a longer period is mutually agreed upon. All applications for a special administrative permit shall be processed in accordance with the standards and procedures applicable to said SAP applications contained in chapter 25 of Part 16 except as otherwise modified by this chapter 18O.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.005. Permitted principal uses and structures.
In all subareas, unless otherwise mentioned in a specified subarea, a building or premises shall be used for the following permitted principal uses and structures. Additional permitted principal uses and structures shall be used only as specified in each subarea (sections 16-18O.028 and 16-18O.029).
1. Childcare centers, kindergartens and special schools.
2. Churches, synagogues, temples, mosques and other religious facilities.
3. Colleges and universities.
4. Congregate care homes and rehabilitation centers.
5. Devices for the generation of energy.
6. Dormitories, fraternity houses and sorority houses, officially affiliated with an accredited college, university or private school and only for the time period that such affiliation is in effect, such that loss of affiliation shall result in the loss of permission for the use.
7. Eating and drinking establishments, including those licensed for the onpremises consumption of malt beverages, wine and/or distilled spirits, subject to further restrictions contained in section 16-18O.029.
8. Establishments for the sale of convenience goods, subject to further restrictions
contained in section 16-18O.029.
9. Greenhouses and garden sheds.
10. Laundry and dry-cleaning stores, collection stations or plants; laundry and dry cleaning establishments where customers operate equipment.
11. Public schools.
12. Retail establishments, subject to further restrictions contained in section
16-18O.029.
13. Single-family, two-family, and multifamily dwellings.
14. Structures and uses required for operation of MARTA, public transit or public utility, but does not include uses involving storage, train yards, warehousing, switching, or maintenance shops as the
primary purpose.
15. Supportive housing.
16. Small discount variety stores, provided that no small discount variety store may be located within 5,280 feet of another
small discount variety store.
17. Short-term rentals, subject to the regulations in Atlanta City Code section 20-1001.
Any principal use and structure not specifically listed above is prohibited in this district, unless otherwise specifically authorized in the subarea regulations.
All commercial sales and service shall be conducted within enclosed permanent structures and there shall be no unenclosed displays of merchandise with the exception of off-street parking and outdoor dining. Outdoor sales or displays are permissible only by special permit as set forth below.
No use or manner of operation shall be permitted which is obnoxious or offensive by reason of odor, smoke, noise, glare, fumes, gas, vibration, unusual danger of fire or explosion, emission of particulate matter, or interference with radio or television communication, or is otherwise incompatible with the character of the district and its relation to adjoining districts.
Pursuant to section 16-28.016 adult businesses are not permitted uses in the district.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2005- 21, §§ 1, 2, 3-25-05; Ord. No. 2005-41(06-O0381), § 35, 7-12-05; Ord. No. 2008-62(06-O0038), § 4L(1), 7-7-08; Ord. No. 2009-24(08-O1251), § 2R, 6-9-09; Ord. No. 2019-15(18-O1702), § 3, 2-13-19; Ord. No. 2019-66(19-O1504), § 13, 12-11-19; Ord. No. 2021-60(21-O0682), § 35, 12-15-21) Sec. 16-18O.006. Permitted accessory uses and structures.
Accessory uses and structures permitted within this district shall include those customarily accessory and clearly incidental to permitted principal uses and structures and specifically includes clubhouses, pools, and other recreation amenities, parking to serve authorized residential and nonresidential uses within the district subject to the restrictions contained in Section 16-18O.022 and elsewhere in this chapter, and electric vehicle charging stations equipped with Level 1, Level 2, and/or DC Fast Charge EVSE.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2014- 53(14-O-1278), § 2(Attach. B), 12-10-14) Sec. 16-18O.007. Special permits.
The following uses are permissible only by additional special permits of the type indicated subject to limitations and requirements set forth in this chapter 18O or elsewhere in this part, and subject to the applicable procedures and requirements set forth in section 16-25.001, et seq.
1. Special use permits. Off-street surface parking (30 spaces or more).
2. Special administrative permits. Outdoor displays of merchandise or sales areas
within the supplemental zone.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.008. Redevelopment requirements.
Any property wherein 60 percent or greater of the principal building is removed or destroyed by any means shall be redeveloped in accordance with the requirements of this chapter and any paving or other accessory structural elements within any required transitional yard shall be removed and buffers provided as required herein, notwithstanding any other provisions in Part 16 to the contrary.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.009. Transitional uses and yards.
1. Adjoining lot with same frontage. Where a lot in this district abuts a lot in any R-1 through R-G or PD-H classification at the side along the same street frontage, and without an intervening street, such lot within this district, or the first 100 feet on such lot if it is wider than 100 feet, shall not be used for any car wash, service station, mortuary or funeral home, sales lot for automobiles, repair garage, or paint and body shop even where otherwise specifically authorized.
2. Transitional height planes.
a. No portion of any structure shall protrude through a height limiting plane beginning the specified number of feet above the point set forth in subsection
16-18O.009(2)(b) below and extending inward over the SPI-15 district at an angle of 45 degrees. The following districts shall be considered protected districts
for purposes of this section 16-18O.009(2):
i. R-1 through R-5;
ii. RG-1 and RG-2;
iii. MR-1, MR-2, and MR-MU; and iv. Landmark, Historic, PD, and SPI districts and district subareas having uses and densities predominantly similar to those permitted in the district classifications listed in subsections (i) through (iii) above.
b. Proximity to districts and measurement applications:
i. For parcels in an SPI-15 district that are contiguous to a protected district, the transitional height plane shall be measured beginning 35 feet above the required SPI-15 setback or transitional yard adjoining the common property line with such protected district.
ii. For parcels in an SPI-15 district that are not contiguous to but are within 150 feet of a protected district, the transitional height plane shall
be measured beginning 15 feet above the nearest lot line of the protected district, provided this transitional height plane shall not extend more than 150 linear feet (measured along the ground) from the protected district up to and into the SPI-15 district. (See diagrams at section 16-29.001(62).)
c. The purpose and intent of this provision is to provide protection for the named
protected districts from nearby looming structures regardless of the presence of an intervening public right-of-way or park or space, public or private street or alley, or any lot or parcel remnant.
d. Transitional height plane measurements shall be applied to parcels on a point-bypoint basis and not average grade.
3. Transitional yards.
a. Where this district adjoins an R-1 through R-G or PD-H classification without an
intervening street, a minimum of 20 feet is required which shall not be used for
the purpose of parking, paving, loading, servicing or any other activity with the exception of private alleys or drives up to ten feet in width. Such yards shall be
planted as approved by the city arborist and maintained as a landscaped strip.
b. Screening. In addition to the above transitional yard requirements, permanent opaque walls six feet in height shall be provided and shall be maintained in sightly condition.
4. Fire safety code requirements. Notwithstanding any other provisions of this chapter, the applicant shall be responsible for ensuring that the plans submitted meet all fire safety code requirements.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 09(18-O-1581), § 10.12, 1-31-19)
Sec. 16-18O.010. Development controls.
1. Bulk limitations. See specific regulations for each subarea at sections 16-18O.028 and 16-18O.029. For purposes of this chapter, and notwithstanding the provisions of Code section 16-29.001(24), mixed-use development is defined as any development which:
a. Contains both residential uses and nonresidential uses as principle uses on the same development site, and
b. The principal building on the site contains both residential and non-residential uses, with at least one of those uses located on the ground level, and the other use(s)
located on any level above the ground level of the same building, and
c. Both of such uses are at least 20 percent of the total floor area, excluding accessory uses.
2. Side and rear yards.
a. Rear yards: 20 feet.
b. Side yards:
i. None for nonresidential uses.
ii. Residential uses: 20 feet, except that the side yard may be reduced to
zero feet when a residential use has no windows adjacent to such yard.
3. Affordable new sales housing units or rental housing units requirements.
a. See specific regulations for the affordable housing bonus for in sections 16-18O.028 and 16-18O.029.
b. Affordable housing shall have the meaning for moderate income affordable housing units set forth in section 19-1006.
c. Affordable requirements shall be in place for a minimum of 20 years from the date
of issuance of the occupancy permit and shall include deed restrictions governing the resale value or rental rate placed on the affordable units.
d. No housing unit associated with a development project for which the affordable housing bonus floor area ratio calculations were applied pursuant to sections 16-18O.028 and 16-18O.029 shall be issued an occupancy permit until such time as
documentation is provided to the bureau of buildings establishing that the affordable housing requirements in this chapter have been met and have been instituted
as part of the warranty deed as an allowable exception to title for each affordable unit that is a part of said development project.
4. Minimum open space requirements. When either the residential or nonresidential component of the development is a minor use of less than 20 percent of the total floor area minimum open space requirements do not apply to such minor use.
a. For residential uses, including all residential components of mixed use developments, open space requirements as indicated on Table I, Land Use Intensity Ratios shall be required for useable
open space (UOSR).
b. For nonresidential uses, including all nonresidential components of mixed-use
developments, minimum public space requirements are indicated in sections 16-18O.028 and 16-18O.029. See section 16-28.012 for definitions and measurements. Required yards and requirements for sidewalk widths which are constructed on private property may be
counted towards this requirement. Such public space may include planted areas, fountains, plazas, hardscape elements related to sidewalks and plazas, and similar features which are located on private property.
c. For mixed uses, the sum of minimum open space requirements specified in subsections a. and b. above for nonresidential and residential shall be met.
d. Residential balconies. Balconies for residential units, which are enclosed on three sides, may be counted towards
UOSR for a maximum depth of six feet.
e. New streets. In addition to new public streets, or private streets which function as public streets being counted towards
UOSR, said streets may also be counted towards public space requirements when the new street meets the following requirements:
i. Connects two other public streets.
ii. Meets sidewalk requirements for the district subarea.
iii. The maximum width shall be 40 feet which shall include, two onstreet parallel parking lanes, two travel lanes and sidewalk extensions at intersections and shall have granite curbs.
iv. When surrounding a park area, new streets shall meet all above requirements along each park edge.
f. On-street parking incentive. New onstreet parking may be counted towards UOSR, or public space requirements
provided the following criteria are met:
i. No on-street parking currently exists in the public right-of-way adjacent
to the project area for which credit is sought;
ii. The new on-street parking is located where there is no existing street
lane;
iii. The on-street parking occupies an entire block face or a minimum distance of 200 feet;
iv. Sidewalk extensions are provided at street intersections; and
v. All other sidewalk requirements of this chapter are met.
g. Relocation of minimum open space requirements. At the option of the property owner, a development's required UOSR, or public space may be relocated
to an offsite parcel provided the following criteria are met:
i. The receiving parcel is adopted in the City of Atlanta Comprehensive Development Plan (CDP), as being a designated recipient parcel;
ii. The receiving parcel contains the required amount of open space and said open space in the receiving parcel is located adjacent to and visible from a public street and accessible to the public during normal city park hours;
iii. All of the open space in the receiving parcel meets the definition of UOSR in section 16-28.010(5)(a)
except that no portion of any public right-of-way shall be included; and iv. The open space in the receiving parcel:
a). Shall provide active or passive recreational amenities.
b). Shall be no greater than three feet above or below the adjacent public sidewalk for a minimum distance of 15 feet from the beginning of the adjacent sidewalk.
c). Shall be visible and accessible from any point along 90 percent of any adjacent sidewalk.
d). Shall permit and encourage pedestrians to walk on a minimum of 80 percent of the surface of the parcel excluding fountains, pedestrian furniture, pedestrian walkways, public art and similar elements, and:
i). When the transferred open space is UOSR, shall provide a minimum of 50 percent of the surface of the parcel with evergreen groundcover such as mondo grass or Liriope spicata, perennial plantings, low shrubs or similar landscaping.
ii). When the transferred open space is public space requirements, shall provide a minimum of 20 percent of the surface of the parcel with evergreen groundcover such as mondo grass or Liriope spicata, perennial plantings, low shrubs or similar landscaping.
5. Pedestrian circulation requirements.
Substitute or alternative pedestrian routes through or between buildings for part or all of the requirements in this chapter may be
authorized by special administrative permit, upon a finding by the bureau of planning that: (i) such pedestrian ways are not inconsistent with the purpose and intent of this chapter; and (ii) such pedestrian ways provide equal or improved pedestrian circulation. That portion of the pedestrian circulation requirement of this chapter which lies within the net lot area shall constitute a corresponding portion of the open space requirements.
6. Showering facilities. All office buildings containing over 50,000 square feet of gross office space shall provide showering facilities, which shall include showers and lockers, in a ratio of at least two showering facilities for every 50,000 square feet of gross office space, which facilities shall be available to all building tenants and their employees, provided that no office building shall be required to exceed a maximum of four showering facilities.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 15(18-O-1702), §§ 4, 5, 2-13-19)
Sec. 16-18O.011. Site limitations.
1. Minimum building façade heights and maximum building heights. See specific regulations for each subarea at sections 16-18O.028 and 16-18O.029.
2. New development shall not contain entire block faces greater than 600 feet in length.
Newly created streets shall function as public streets and shall connect two other public streets.
3. Properties adjacent to Peachtree Creek:
a. Shall have a minimum of a 100-foot buffer from the upper most edge of the stream bank. Said buffer shall be completely landscaped with trees or evergreen groundcover such as mondo grass or Liriope spicata, perennial plantings, low shrubs or similar landscaping, excluding trails, fountains, pedestrian
furniture, pedestrian walkways, public art and similar elements as approved by the director of the bureau of planning.
b. Shall have a local street between any development and said buffer.
c. The primary pedestrian entrance to all uses with street frontage:
i. Shall face and be visible from the creek.
ii. Shall be directly accessible from the sidewalk adjacent to the street.
iii. Shall open directly onto the adjacent sidewalk, or an outdoor dining area
or plaza adjacent to the sidewalk.
4. Service stations, where permitted in this chapter shall be restricted to sites that are a minimum of 0.5 mile away from
any other existing service station. This minimum distance shall be measured
from the closest property line of the subject parcel to the closest property line of any parcel with an existing service
station.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 15(18-O-1702), § 6, 2-13-19)
Sec. 16-18O.012. Sidewalks.
Public sidewalks shall be located along all public streets and shall have minimum widths as specified herein. Sidewalks shall consist of two zones: A street furniture and tree planting zone and a clear zone. The following regulations shall apply to all public sidewalks:
1. Street furniture and tree planting zone requirements. The street furniture and
tree planting zone shall have a minimum width of five feet. Said zone shall be located immediately adjacent to the curb and shall be continuous. Said zone shall meet the tree planting requirements of
section 16-18O.012(3). In addition to the required planting of trees, this zone may also be used for the placement of street furniture including utility poles, waste receptacles, fire hydrants, traffic signs, newspaper vending boxes, bus shelters,
bicycle racks and similar elements in a manner that does not obstruct pedestrian access or motorist visibility and as
approved by the director of the bureau of planning.
2. Clear zone requirements. Said zone shall be located immediately contiguous to the street furniture and tree planting zone
and shall be continuous. Said zone shall be hardscape, and shall be unobstructed
for a minimum height of eight feet, by any permanent or, nonpermanent element. The following streets shall have these minimum clear zone widths:
a. Piedmont Road and Sydney Marcus Boulevard: 15 feet.
b. Lindbergh Drive, Morosgo Drive, all other streets in the commercial subareas and streets adjacent to Peachtree Creek: Ten feet.
c. Lindbergh Drive and Lindbergh Way (only for properties bound by Piedmont Road, Lindbergh Drive and Lindbergh Way): Five feet.
d. All other streets: Six feet.
3. Street tree planting requirements. Street trees are required and shall be planted in the ground a maximum of 40 feet on
center within the street furniture and tree planting zone and spaced equal distance between street lights. All newly planted trees shall be a minimum of four inches in caliper measured 36 inches
above ground, shall be a minimum of 12 feet in height, shall have a minimum mature height of 40 feet, and shall be limbed up to a minimum height of seven feet. Trees shall have a minimum planting area of 25 square feet. All plantings, planting replacement and planting
removal shall be approved by the city arborist. The area between required plantings shall either be planted with evergreen ground cover such as mondo grass or
Liriope spicata, or shall be paved.
4. Tree grates. Tree grates are not required where all sidewalk width requirements
are met. Where tree grates are otherwise installed, they shall be a minimum of
four feet by eight feet, shall be a type specified by the director of planning in accordance with uniform design standards utilized by the director for placement of such objects in the public right-of-way, and shall be placed within the street
furniture and tree planting zone. Where tree grates are not required or otherwise installed, tree planting areas shall be
permitted to be planted with evergreen ground cover such as mondo grass or Liriope spicata.
5. Paving. All special paving within the street furniture and tree planting zone
along Peachtree Street shall utilize six inch by six inch pavers and shall be a
type specified by the director of planning in accordance with uniform design
standards utilized by the director for placement of such objects in the public right-of-way.
6. Nothing shall be erected, placed, planted or allowed to grow in such a manner as to impede visibility within visibility triangles at street intersections between the heights of two and one-half feet and eight feet
above grade. See section 16-28.009, Visibility at intersections.
7. No awning or canopy shall encroach more than five feet over the required sidewalk.
8. Where property within this district abuts an R, RG, or PD-H district without an
intervening street, the sidewalk area within 20 feet of such districts shall taper as necessary to provide a smooth transition to the existing R, RG, or PD-H districts sidewalk. In the event that the abutting R, RG, or PD-H district has no
existing sidewalk, the sidewalk shall taper to a width of six feet.
9. Decorative pedestrian lights, where installed, shall be placed a maximum of 40 feet on center and spaced equal distance between required trees along all streets.
Where installed, said lights shall be located within either the street furniture and tree planting zone or the
supplemental zone. All said lights shall be Atlanta Type C as approved by the
planning bureau.
10. Every economically feasible effort shall be made to place utilities (excluding the high tension power lines running along
Piedmont Road) underground or to the rear of structures to allow for unobstructed use of sidewalks.
11. Trash receptacles or similar elements, where installed, shall be a type specified by the director of planning in accordance with uniform design standards utilized
by the director for placement of such objects in the public right-of-way and shall be placed within the street furniture and tree planting zone.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.013. Supplemental zone.
For purposes of these regulations, the area between any building and the nearest edge of the required sidewalk shall be defined as the supplemental zone. Supplemental zones shall meet the following requirements. Except as otherwise specified below, the square footage contained within a supplemental zone which meets all the following supplemental zone requirements may be counted towards TOSR, UOSR or public space requirements.
1. Supplemental zone widths. Piedmont Road, Sidney Marcus Boulevard, Morosgo Drive, Lindbergh Drive (with the exception of sidewalks between Piedmont Road and Lindbergh Way), and the entire
subarea 9 shall be a minimum of five feet.
2. Supplemental zone general requirements.
a. Terraces, porches and stoops shall have a maximum finished floor height of 24 inches above finishedgrade.
b. Street fronting, sidewalk level residential units shall provide a supplemental zone with a minimum width of five feet which shall be landscaped with trees or evergreen ground cover such as mondo grass or Liriope spicata, perennial plantings, low shrubs or similar landscaping, with the exception of terraces, porches, stoops and entrance
walkways, which shall occupy a maximum of two-thirds of the supplemental zone area.
c. The supplemental zone shall be no more than 24 inches above the adjacent public sidewalk for a minimum linear distance of 15 feet from the nearest edge of the adjacent public sidewalk, unless existing topographical considerations render this requirement unreasonable; and
d. Any authorized walls surrounding landscaped and grassed areas shall not exceed a maximum height of 24 inches, except retaining walls, which shall not exceed a maximum height of 36 inches unless existing topography requires a retaining wall of greater height.
e. Fencing is permitted only when:
i. The supplemental zone is located adjacent to sidewalk level residential units; or ii. Said fencing is used to separate authorized outdoor dining from the required sidewalk.
3. Supplemental zones containing a depth of 15 feet or less shall meet the following additional requirements:
a. No balcony shall encroach more than five feet into the supplemental zone area.
b. Shall not be counted towards TOSR, UOSR or public space requirements unless visible and accessible to the general public from the adjacent public sidewalk, with the exception of areas adjacent to sidewalk level residential units.
4. Supplemental zones containing a depth greater than 15 feet shall meet the following additional requirements:
a. When adjacent nonresidential ground floor uses are provided, shall be counted towards public space requirements only when a minimum of 80 percent of said zone's surface, excluding fountains, pedestrian furniture, public art and similar elements, is accessible to the general public from the adjacent public sidewalk, and when all sides of buildings fronting said zone meet the requirements of section
16-18O.027(1).
b. Shall be visible and accessible from any point along 90 percent of any adjacent sidewalk.
c. Shall permit and encourage pedestrians to walk on a minimum of 80 percent of the surface of the parcel excluding fountains, pedestrian furniture, public art and similar elements.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 15(18-O-1702), § 7, 2-13-19)
Sec. 16-18O.014. Relationship of building to street.
1. For purposes of this chapter, sidewalk-level shall be defined as any floor of a building with a finished-floor elevation less than or equal to five feet above the adjacent sidewalk or less than or equal to five feet below the adjacent sidewalk.
2. Building floors shall be delineated at third story above sidewalk level and lower and shall be executed through windows, belt courses, cornice lines or similar architectural detailing.
3. The primary pedestrian entrance for pedestrians to access all sidewalk level uses and business establishments with street frontage:
a. Shall face and be visible from the street.
When located adjacent to a storefront street, said entrance shall face and be visible from such street.
b. Shall be directly accessible and visible from the sidewalk.
c. Shall remain unlocked during business hours for nonresidential uses.
d. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five
foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit.
This provision shall not apply to singlefamily and two-family residential structures.
4. A street address number shall be located directly above the primary building entrance, shall be clearly visible from the sidewalk and shall be a minimum of six inches in height.
5. Buildings with residential uses at the sidewalk level shall meet the following regulations:
a. All primary pedestrian entrances not adjacent to a public sidewalk shall be linked to the public sidewalk with a pedestrian walkway a minimum of fivefeet wide.
b. All such buildings with more than four residential units that are adjacent to the sidewalk shall have individual entrances to such units directly accessible from the sidewalk and shall open directly onto the adjacent sidewalk, park, plaza, terrace
or porch adjacent to the sidewalk.
c. Such buildings shall have windows at sidewalk level on each street frontage façade which are substantially similar in size to the sidewalk level front façade
windows.
6. Fences and walls shall meet the following regulations:
a. For residential uses adjacent to the sidewalk, fences shall not exceed 42 inches in height when located between the
primary building and the street. For nonresidential uses adjacent to the sidewalk, fences are prohibited when located between the building and the sidewalk except where specifically authorized elsewhere in this chapter for outdoor dining.
b. Retaining walls located adjacent to a sidewalk along a public street shall not exceed a height of two feet and the
combined height of a fence where otherwise authorized and retaining wall shall not exceed a height of five feet, unless existing topography prohibits retaining walls of a lesser height. Retaining walls shall be architecturally finished poured concrete or shall be faced with
stone, brick or smooth stucco. See section 16-29.001(25)b.
c. No walls, except retaining walls, shall be located between the street and any building, with the exception of screening for authorized off-street loading areas.
d. Fences and walls located between the primary building and the lot line and not exceeding six feet in height may be
erected, but shall not be permitted between the primary building and the street.
7. No barbed wire, razor wire, chain link fence or similar elements shall be visible from any public plaza, ground level or sidewalk level outdoor dining area or public right-of-way.
8. Gasoline fuel dispenser structures and associated vehicular services such as air pumps and car washes shall not be located between a building and the street.
9. Drive-through service windows and drive-in facilities shall not be permitted.
10. Fenestration (non-storefront streets): Shall be provided at the minimum percent as specified herein and in the Lindbergh SPI-15 Fenestration Table. Fenestration shall not utilize painted glass, reflective glass or other similarly treated or opaque windows. tinted glass shall have a transmittance factor of 50 percent or greater and shall have a visible light reflectance factor of ten or less. Fire stations and churches are exempt from all fenestration requirements.
a. Street-fronting non-residential uses along arterial streets and collector streets shall meet the following sidewalk-level fenestration requirements:
i. The length of a façade without intervening fenestration or entryway shall not exceed 20 feet.
ii. Fenestration shall begin at a point not more than three feet above the sidewalk, to a height no less than ten feet above the sidewalk; or iii. Fenestration shall begin at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three or more feet above the sidewalk; or iv. Fenestration shall begin at a point not more than sidewalk level, to a height no less than ten feet above the finished floor elevation when the finished floor elevation is below the sidewalk.
c. Such buildings shall have windows at sidewalk level on each street frontage façade which are substantially similar in size to the sidewalk level front façade
windows.
Table 1: Lindbergh SPI-15 Fenestration Table (Non-storefront streets)
Use Arterial or Collector Street Local or Private Street Residential 30% of street façade length 30% of street façade length Non-Residential 50% of street façade length 30% of street façade length (Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 15(18-O-1702), § 7, 2-13-19; Ord. No. 2026-05(26- O-1001), § 8, 2-25-26)
Sec. 16-18O.015. Signage.
Refer to section 16-28A, Sign ordinance.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.016. Lighting and storefront illumination.
1. All lighting including all parking decks and lots and lit canopies shall reduce light spillage onto residentially used properties by providing cutoff luminaries which have a maximum 90 degree illumination.
2. All lighting that up-lights trees, buildings or other elements shall be located a minimum height of eight feet above the sidewalk, driveway or pedestrian area.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.017. Loading areas, loading dock entrances and building mechanical and accessory features.
1. Loading areas. Dumpsters and loading areas shall be screened so as not to be visible from any public plaza, ground level or sidewalk level outdoor dining area, public sidewalk or public right-of way. In addition, dumpsters and loading areas serving residential uses shall be enclosed with opaque walls a minimum of six feet in height.
2. Loading dock entrances for nonresidential uses shall be screened so that loading docks and related activity are not visible from the public right-of-way.
3. Building mechanical and accessory features:
a. Shall be located to the side or rear of the principal structure and shall be in the
location of least visibility from the public right-of-way. Screening with plant or fence materials shall be required if the equipment is otherwise visible from the public right-of-way.
b. When located on rooftops shall be incorporated in the design of the building and screened with building materials
similar to the building.
c. Shall not be permitted between the building and any public street.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.018. Off-street loading requirements.
Loading requirements: Minimum off-street spaces shall be provided according to the Lindbergh SPI-15 loading table. All loading spaces shall provide vertical clearance of 14 feet and shall not be located within the required sidewalk.
See section 16-18O.017 for screening requirements. Reduction of loading spaces may be approved by the director of the office of zoning and development subject to a shared loading arrangement that avoids conflicting loading demands.
Table 1: Lindbergh SPI-15 Loading Table Unit of Measure Required Loading Spaces 12' x 35' 12' x 55' Residential Dwellings/ Lodgings Less than 20 units None None 20 to 50 units 1 None 51 to 200 units 2 None 201 units and above 3 None All Other Uses Up to 10,000 sq. ft. floor area None None 10,001 sq. ft.
to 40,000 sq.
ft. floor area 1 None 40,001 sq. ft.
to 100,000 sq. ft. floor area 2 None 100,001 sq.
ft. to 250,000 sq.
ft. floor area 2 1 250,001 sq.
ft. to 500,000 sq.
ft. floor area 2 2 500,001 sq.
ft. floor area and above 2 3 (Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 15(18-O-1702), § 9, 2-13-19)
Sec. 16-18O.019. Curb cuts and parking structures.
1. All sidewalk paving materials shall be continued across any intervening driveway.
2. Driveways shall have a band of textured concrete adjacent to the street which is in-line with and equal in width to the street furniture zone and shall have a textured band of concrete adjacent to the sidewalk which is in-line with and equal in width to the supplemental zone.
3. Except as authorized in section 16-18O.011(2), curb cuts within individual blocks shall be a minimum of 600 feet apart except that properties with more than one front yard may have at least two curb cuts.
4. Driveway and curb cuts shall be limited to one-way entrances a width of 12 feet or two-way entrances a width of 24 feet, unless otherwise permitted by the commissioner of transportation.
5. No circular drives shall be located between any building and any public street with the exception of hotels.
6. Curb cuts and driveways shall not be permitted on any storefront street when access may be provided from a side or rear street, with the exception of hotel patron drop-off drives.
7. Unless authorized by section 16-18O.019(5), parking areas or driveways, except for a driveway to reach the side yard or rear yard or an on-site parking facility, are not permitted between the sidewalk and a building, and shall be
perpendicular to any adjacent street.
8. Entrances to garages and carports that serve a single residential unit shall face the rear yard, or a side yard which has no street frontage.
9. All contiguous ground-floor residential units shall share one common drive, located in rear yards or side yards without street frontage, to serve garages, carports and parking areas.
10. In addition to section 16-28.028, parking deck façades shall have the appearance of a horizontal storied building.
11. Additional parking deck treatment along specific streets:
a. When located along storefront streets.
Shall meet the requirements of section 16-18O.027.
b. Properties at the intersection of East Lindbergh Drive and East Lindbergh Way, and east of Piedmont Road. Shall be
landscaped with mature trees and ground cover only to a depth of 20 feet from the eastern most property line. No additional landscaping shall be required for parking decks on these properties.
c. When located along all other streets.
i. Shall meet the requirements of section 16-18O.027; or ii. Shall meet the requirements of section 16-18O.014(5); or iii. Shall provide a continuous minimum
five-feet wide landscaped strip between the structure and the public sidewalk, except at ingress and egress points into the structure. The landscaped strip shall be planted with street trees spaced a maximum distance of 20 feet on center, which shall also meet the tree requirements in section 16-18O.012(3), Sidewalks. The landscape strip shall
also be planted with evergreen ground cover such as mondo grass, Liriope spicata, ivy or evergreen shrubs with a maximum mature height of 24 inches. All plantings, planting replacement and planting removal shall be approved by the city arborist.
12. Notwithstanding the provisions of section 16-28.006(10), a common or joint driveway may be authorized by the director of the bureau of planning when adjacent lots have direct vehicular access to a street, and a driveway from a private street which functions as a public street may be authorized by the director of the bureau of planning, based on traffic considerations, when a perpetual easement agreement is agreed upon by all affected property owners and a copy of such agreement is provided to the bureau of planning.
13. All developments shall have sidewalks with a minimum width of four feet connecting ground level parking to the public sidewalks and to all building entrances. See section 16-18O.021.
14. No drop-off lanes shall be permitted along public streets.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2008- 67(08-O-0196), § 5, 7-21-08; Ord. No. 2020-33(20- O-1381), § 26, 6-23-20)
Sec. 16-18O.020. Lighting, security, and maintenance requirements for parking
structures and surface parking lots.
All surface parking lots and structures, whether a nonconforming principle use (see section 16-18O.022) or accessory in use, and whether serving commercial or noncommercial uses, shall have the following minimum requirements:
1. Lighting shall be provided throughout all parking facilities to equal a minimum of two footcandle of light. A footcandle of light is a uniformly distributed flux of one lumen on a surface of one square foot in area. Where applicable, public street lighting may be utilized to either partially or totally fulfill the lighting requirements; however, where such street lighting is removed, it shall be the responsibility of the parking facility to independently provide these required
levels of illumination.
2. [Reserved.]
3. Parking facilities shall be maintained in a clean, safe and sanitary condition. Parking spaces and driving lanes shall be clearly defined and maintained as such.
Parking lots shall not be operated when any damage impairs the drivability of the parking lot. See section 16-28.014 for additional requirements.
4. Parking facilities operating before the effective date of this section shall have 48 months to comply herewith.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2008- 67(08-O-0196), § 6, 7-21-08)
Sec. 16-18O.021. Minimum landscaping for surface parking lots, barrier requirements.
The requirements of City of Atlanta Code of Ordinances, chapter 158 Vegetation, article II Tree Protection, section 30 Parking lot requirements shall apply to this district except as modified as follows:
1. Said parking lot requirements shall apply to all lots regardless of size;
2. All required landscaped areas shall be planted with evergreen groundcover or
shrubs with a maximum height of 30 inches; and
3. All landscaped buffer strips along sidewalks and public rights-of-way shall have a minimum of one tree with a
minimum caliper of two and one-half inches.
4. Surface parking lots operating before the effective date of this section shall have 48 months to comply herewith.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.022. Off-street parking requirements.
1. Parking requirements. The minimum number of parking spaces required and maximum number allowed shall be in accordance with the following SPI-15 Lindbergh Parking Tables. Any variation to increase the maximum allowable parking requirement shall be based upon criteria including, but not limited to, the following:
a. Tenant demand based for on-site uses;
and
b. Parking efficiency and utilization for onsite uses; and
c. Parking available off-site within onequarter-mile radius.
2. All parking areas and structures. All parking areas and structures shall have delineated walkways at a minimum width of four feet connecting parking to the required sidewalks and building entrances.
3. Office uses, additional requirements.
a. All office developments over 100,000 square feet shall reserve and designate at least five percent of the parking spaces "Carpool Only." Such spaces shall be
located near the building's entrance or other preferable locations within the employee parking areas as approved by the commissioner of transportation; and
b. All new parking structures shall be built to accommodate vanpool access at entry
level. The minimum ceiling height for vanpools is eight feet two inches.
4. Off-street surface parking.
a. Shall not be located between the principal structure and the street.
b. Shall be accessory to a permitted principal use only, provided that parking spaces
serving this use may also serve another principal permitted use that is located off site, in a shared parking scenario.
5. Electric vehicle charging stations. All automobile parking facilities shall include electric vehicle charging stations in a ratio of at least one station for every 100 automobile parking spaces.
No development shall be required to exceed a maximum of 12 spaces.
6. [Park-for-hire surface parking lots:] Parkfor-hire surface parking lots are prohibited.
7. [Park-for-hire parking decks:] Park-for-hire parking decks are permitted only if specifically authorized in a particular subarea.
Table 2A: SPI-15 Lindbergh Parking Table (Subareas 1 through4&5 through 8, subject to use restrictions)
Parking Spaces Minimum Maximum Residential Dwellings Hotels and motels (spaces per lodging unit) None 1.0 Residential Dwellings
• Per each one bedroom unit
• Per each two or morebedroom unit None 1.25 2.25 Non-residential Uses (Spaces per 1,000 sq. ft. of floor area)
Eating and drinking establishments None 2.5 Commercial/ retail (not eating and drinking establishments) None 2.5 Institutional None 2.5 Office None 2.5 Recreation/ Entertainment None 1.5 Table 2A: SPI-15 Lindbergh Parking Table (Subareas 1 through4&5 through 8, subject to use restrictions)
Parking Spaces Minimum Maximum All Other Uses None 2.0 Table 2B: SPI-15 Lindbergh Parking Table (Subarea 9)
Parking Spaces Minimum Maximum Residential Dwellings Hotels and motels (spaces per lodging unit) None 0.5 Residential Dwellings 1
• Per each one bedroom unit
• Per each two bedroom unit
• Per each three or morebedroom unit None 0.75 1.00 1.25 Non-residential Uses (Spaces per 1,000 sq. ft. of floor area)
Commercial/ retail (not eating and drinking establishments) None 3.70 Childcare None 1.70 Health Club None 3.70 Office None 2.67 All Other Uses None 2.0 1 A maximum of one visitor parking space may be provided for every four units.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2005- 41(06-O-0381), § 36, 7-12-05; Ord. No. 2008-62(06- O-0038), §§ 4L(2), 6N(1), 7-7-08; Ord. No. 2009- 24(08-O-1251), § 2R(3), 6-9-09; Ord. No. 2019- 15(18-O-1702), § 10, 2-13-19; Ord. No. 2020-33(20- O-1381), § 27, 6-23-20)
Sec. 16-18O.023. Transportation management plan.
Transportation management plan. The bureau of buildings shall not issue building permits for office components of any development in this district until such time as the developer or leasing agent for each of the office components has submitted to the director of the bureau of planning, a transportation management plan (TMP) for each such component that has more than 25,000 square feet of total gross leasable floor area of space. The TMP shall contain strategies to reduce single occupancy vehicle trips generated by the project by a minimum of 25 percent during a five-year period from the initial date of occupancy.
The TMP shall be based on an annual commute mode survey. Said survey shall be submitted on the day of initial occupancy and on each yearly anniversary of the date thereafter, until otherwise notified by the director of the bureau of planning. The survey shall be based on a continuous five-day workweek for all employees arriving at the work site between 6:00 a.m. and 10:00 a.m., Monday through Friday. Based upon the survey information, the employer shall develop a TMP.
The TMP shall include, but not be limited to:
1. An estimate of the number of employees and visitors per hour that are expected to use rail and bus transit throughout the
day.
2. A description of how information regarding the new or existing transit stops and building access to such stops will be
displayed on the property in indoor or outdoor locations.
3. A program to promote and maintain employee participation in carpooling, vanpooling, and use of mass transit, including a method of monitoring the number of ride sharers and their travel patterns.
4. A statement committing to support, and participate in, the Buckhead Area
Transportation Management Association (BATMA) and its funding.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.024. Minimum bicycle parking requirements.
See section 16-28.014(6), Bicycle parking requirements.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 09(18-O-1581), § 12, 1-31-19)
Sec. 16-18O.025. Pedestrian bridges and tunnels.
Pedestrian bridges and tunnels are prohibited when located above or below public streets, private streets which function as public streets connecting two other public streets, or other public rights-of-way.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.026. Zero-lot-line development.
Zero-lot-line subdivision is permitted for residential uses provided a minimum of 1,000 square feet in lot area is provided. The additional requirements of section 16-28.007 shall also apply.
(Ord. No. 2001-91, § 1, 7-11-01) Sec. 16-18O.027. Specific regulations for storefront streets.
Properties which front Piedmont Road north of Lindbergh Drive, Sydney Marcus Boulevard and Morosgo Drive, and Main Street shall be deemed to constitute storefront streets within the meaning of this chapter and shall meet the following regulations:
1. Street-fronting buildings including parking decks shall meet the following sidewalk level requirements:
a. Parking, storage, or digital industry switchboards, power generators and
other relay equipment and rooms housing such equipment shall be permitted, with the exception of a minimum depth of 20 feet of the ground floor street frontage beginning at any building façade along the public sidewalk.
b. The length of façade without intervening fenestration or entryway shall not exceed 20 feet.
c. Fenestration shall be provided for a minimum of 65 percent of the length of the frontage:
i. Beginning at a point not more than three feet above the sidewalk, to a height no less than ten feet above the sidewalk, or ii. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three or more feet above the sidewalk, or iii. Beginning at a point not more than sidewalk level, to a height no less than ten feet above the finished floor elevation when the finished floor elevation is below the sidewalk.
d. Properties with ground floor residential uses on Morosgo Drive and greater than 350 feet east of Piedmont Road shall be permitted to substitute the fenestration requirements of section 16-18O.027(1)(c) with the fenestration requirements of section 16-18O.014(5)(c).
e. Fenestration shall not utilize painted glass, reflective glass or other
similarly treated or opaque windows.
Entrances may be counted towards fenestration requirements.
2. Minimum building façade height: 24 feet along each façade visible from the public right-of-way.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2019- 15(18-O-1702), § 11, 2-13-19)
Sec. 16-18O.028. Specific regulations for commercial subareas.
1. In addition to those uses authorized in section 16-18O.005, a building or premises may be used for the following permitted uses and structures:
a. Banks and financial institutions.
b. Business or commercial schools.
c. Car rentals provided that surface parking lots are not utilized.
d. Clubs and lodges.
e. Commercial recreational establishments, including bowling alleys, theaters, convention halls, places of assembly and similar uses with primary activities conducted
within fully enclosed buildings.
f. Conversion of industrial buildings to multi-family.
g. Digital industry switchboards, power generators and other relay equipment and rooms housing such equipment. The additional requirements of section 16-18O.027(1)(a) shall also apply.
h. Hotels and motels.
i. Museums, galleries, auditoriums, libraries, and similar cultural facilities.
j. Nursing homes, convalescent homes and similar care facilities.
k. Offices, studios, clinics (including veterinary), laboratories and similar uses, but not blood donor stations except at
hospitals. Veterinary clinics including all kennels and accessory areas shall be
enclosed within sound proof buildings when located within 300 feet of any residential use from the closest point of the nearest residential building to the
closest point of the veterinary clinic.
l. Parking structures, including park-forhire, that are below grade or of two or more stories above ground along all street frontages.
m. Professional or personal service establishments.
n. Repealed.
o. Sales and leasing agencies.
p. Sales and repair establishments for home appliances, bicycles, lawn mowers and
similar household goods, with the exception of Piedmont Road.
q. Vault-storage facility.
r. Service stations with or without car washes, and battery exchange stations.
s. Single room occupancy residence.
t. Repealed.
u. Tailoring, custom dressmaking, and millinery.
v. Trade schools.
w. Any broadcasting tower or line-of-sight relay device for telephonic, radio, digital or television communications, provided
that:
i. Such tower or relay device is relocated from or is a substitute for a similar tower or device that existed as of the date of this chapter on a lot located west of Piedmont Road and adjoining but outside of the Lindbergh SPI district; and ii. Once relocated or substituted, the
relocated or substituted tower or device shall be located 200 feet or more from any off-site residential districts or residential use not located within the SPI-15 district, and when
such tower or device is greater than 200 feet in height, when located a distance which is greater than or equal to the height of the tower or device from a residential district or residential use which is not in the SPI-15 district.
x. Urban gardens.
y. Market gardens.
2. A building or premises may be used for the following permitted accessory uses and structures:
a. Car washes.
b. Public schools.
c. Repair garages, paint and body shops in Subarea 2 through subarea 4.
d. Structures and uses required for operation of MARTA, public transit or public utility, but does not include uses involving storage, train yards, warehousing, switching, or maintenance shops as the
primary purpose.
3. The following uses are permissible only by special permit:
a. Special use permit.
i. Broadcasting towers, line-of-sight relay devices for telephonic, radio or television communications when located 200 feet or more from any off-site residential districts or residential uses not located within the SPI-15 district and with the exception of such uses permitted in section 16-18O.028(1)(w), and when such towers or devices are greater than 200 feet in height, when located a distance which is less than or equal to the height of the tower or device from a residential district or residential use which is not in the SPI-15 district.
ii. Dormitories, fraternity houses and sorority houses, officially affiliated with an accredited college, university or private school and only for the time period that such affiliation is in effect, such that loss of affiliation shall result in the loss of permission
for the use.
iii. Helicopter landing facilities or pickup or delivery stations.
iv. Outdoor amusement enterprises, exhibits, entertainment, meetings, displays or sales areas, or outdoor areas for religious ceremonies of 90 days duration or longer.
v. Repair garages, paint and body shops in Subarea 1.
vi. Nursing homes, personal care homes, assisted living facilities rehabilitation centers.
vii. Shelter.
viii. Party house provided that the use shall be prohibited within 150 feet of a property zoned R-1, R-2, R-2A,
R-2B, R-3, R-3A, R-4, R-4A, R-4B,
R-5, RG, MR or property used for residential purposes measured from property line to property line.
b. Special administrative permit.
i. Farmers' markets limited to commercial Subareas 1, 2, 3 and 4.
4. Development controls (concurrency requirement). Commercial subareas in section 16-18O.028(7) through section 16-18O.028(9) that are required to have multi-family dwellings, duplexes or single-family dwellings shall meet the following requirements:
a. Allowable nonresidential floor area shall not be permitted to exceed 500,000 square feet until such time as 100,000 square
feet of allowable residential floor area is built and such residential units are issued an occupancy permit.
b. At such time as the above requirement in section 16-18O.028(4)(a) is satisfied, allowable nonresidential floor area shall not exceed an additional 250,000 square feet until such time as an additional 50,000
square feet of allowable residential floor area is built and such residential units are issued an occupancy permit.
c. At such time as the above requirement in section 16-18O.028(4)(b) is satisfied,
developments may continue to add additional allowable square footage for uses as prescribed in the ratio established in the above section 16-18O.028(4)(b).
5. Site limitations.
a. Minimum building façade heights:
i. Subarea 1: 18 feet along each façade visible from the public right-of-way.
ii. Subarea 2 through subarea 4, and subarea 9: 24 feet along each façade visible from the public right-of-way.
b. Maximum building heights:
i. Subarea 1: Structures which are within 150 feet of any R-1 through R-G or PD-H classification shall have a maximum height of 35 feet along each façade visible from the public right-of-way. Structures that are between 150 feet and 300 feet from any R-1 through R-G or PD-H classification shall have a maximum height of 52 feet along each façade
visible from the public right-of-way.
ii. Subarea 2 through subarea 5: 225 feet along each façade visible from the public right-of-way.
iii. Subarea 9: Maximum building heights shall conform to Attachment C entitled MARTA Lindbergh City Center Station SPI-15 SA-9
Height Maximums.
6. Specific additional regulations for Subarea 1—Miami Circle Commercial.
a. Permitted uses and structures.
i. Business service establishments, including those providing duplicating, printing, maintenance, communications, addressing, mailing, bookkeeping or guard services.
ii. Warehouse, storage facilities and wholesaling limited to no more than 15,000 square feet.
b. Special use permit. Warehouse, storage facilities and wholesaling greater than
15,000 square feet.
c. Development controls.
i. Maximum permitted floor areas without bonuses:
a). For nonresidential uses, floor area shall not exceed an amount equal to one times net lot area.
b). For residential uses, floor area shall not exceed an amount equal to six hundred ninety-sixone thousandths times gross lot area.
c). For mixed use, floor area ratio (FAR) shall not exceed one and six hundred ninety-six-one thousandths times net lot area [the sum of the nonresidential
(i) and residential (ii) above], but in no event greater than the maximum ratios permitted for each (See section 16-29.001(24)).
ii. Maximum permitted floor areas with bonuses.
a). For nonresidential bonus: None.
b). For residential uses (affordable housing bonus): Floor area shall not exceed an amount
equal to two times gross lot area provided that 20 percent or more affordable sales housing units or rental housing units are provided for that portion of residential units.
c). For residential developments (ground-floor retail bonus):
Floor area shall not exceed an amount equal to two times gross lot area provided that street-fronting, sidewalk level retail establishments comprise a minimum of 50 percent of the building footprint limited to the first floor level and meet all of the requirements for storefront streets (section 16-18O.027).
d). For combined bonuses: Under no circumstances shall the floor area of any development with bonuses exceed an amount equal to two times gross lot area.
d. Public space. For nonresidential uses, including all nonresidential components
of mixed-use developments, a minimum of five percent of the net lot area shall be public space.
7. Specific additional regulations for Subarea 2—Sydney Marcus Commercial.
a. Development controls. 20 percent of all floor area shall be multi-family dwellings, duplexes or single-family dwellings (per section 16-18O.028(4)):
i. For nonresidential uses, floor area shall not exceed an amount equal to two times net lot area.
ii. For residential uses, floor area shall not exceed an amount equal to two
times gross lot area.
iii. For mixed use, floor area ratio (FAR) shall not exceed two times net lot
area [the sum of the nonresidential
(i) and residential (ii) above], but in no event greater than the maximum ratios permitted for each (See section 16-29.001(24)).
b. Public space. For nonresidential uses, including all nonresidential components
of mixed-use developments, a minimum of 20 percent of the net lot area shall be public space.
8. Specific additional regulations for Subarea 3—Piedmont Commercial.
a. Development controls. 20 percent of all floor area shall be multi-family dwellings, duplexes or single-family dwellings (per section 16-18O.028(4)) with the exception of lots with Piedmont Road frontage which exist before January 1, 2001 and
have a maximum depth of 350 feet: none.
b. Maximum permitted floor areas without bonuses.
i. For residential uses, floor area shall not exceed an amount equal to four
and two-tenths times net lot area.
ii. For nonresidential uses, floor area shall not exceed an amount equal to four times net lot area.
iii. For mixed use, floor area ratio (FAR) shall not exceed eight and twotenths times net lot area [the sum of the nonresidential (i) and
residential (ii) above], but in no event greater than the maximum ratios permitted for each (see section 16-29.001(24))
c. Maximum permitted floor areas with bonuses.
i. For nonresidential bonuses: None.
ii. For residential uses (affordable housing bonus): Floor area shall not exceed an amount equal to eight
and two-tenths times gross lot area provided that 20 percent or more affordable sales housing units or rental housing units are provided for that portion of residential units.
d. Public space. For nonresidential uses, including all nonresidential components
of mixed-use developments, a minimum of ten percent of the net lot area shall be public space.
9. Specific additional regulations for Subarea 4—Garson Commercial.
a. Development controls. 20 percent of all floor area shall be multi-family dwellings, duplexes or single-family dwellings (per section 16-18O.028(4)).
i. For nonresidential uses, floor area shall not exceed an amount equal to three times net lot area.
ii. For residential uses, floor area shall not exceed an amount equal to three
times gross lot area.
iii. For mixed use, floor area ratio (FAR) shall not exceed three times net lot
area [the sum of the nonresidential
(i) and residential (ii) above], but in no event greater than the maximum ratios permitted for each (see section 16-29.001(24)).
b. Public space. For nonresidential uses, including all nonresidential components
of mixed-use developments, a minimum of 30 percent of the net lot area shall be public space.
10. Specific additional regulations for Subarea 9—MARTA Lindbergh City Center.
a. Prohibited uses:
i. Adult businesses.
ii. Car rental establishments.
iii. Car washes.
iv. Helicopter landing facilities.
v. Nursing homes.
vi. Park-for-hire establishments vii. Repair garages, paint and body shops.
viii. Sales or repair of any motorized vehicle.
ix. Sales or repair establishments for home appliances, lawn mowers and similar household goods.
x. Service stations with or without car washes, and battery exchange stations.
xi. Single-family and two-family residential dwellings.
xii. Storage units.
xiii. Vault storage facilities.
b. Maximum permitted floor areas:
i. For residential uses, floor area shall not exceed an amount equal to four
and two-tenths times net lot area.
ii. For nonresidential uses, floor area shall not exceed an amount equal to four times net lot area.
c. [Setback:] All parcels that front Piedmont Road and which are north of Morosgo
Drive shall have a 50-foot front yard setback from the adjacent Piedmont Road property line.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2001- 96, §§ ILVII, ILVIII, 12-12-01; Ord. No. 2004-53, §§ 23A, 23B, 8-20-04; Ord. No. 2008-62(06-O0038), §§ 4L(3), 5L, 5M, 6N, 7-7-08; Ord. No.
2009-24(08-O-1251), § 2R(2), 6-9-09; Ord. No.
2009-61(09-O-1076), § 2(2), 10-13-09; Ord. No.
2011-39(10-O-1773), § 3W, 9-15-11; Ord. No.
2014-53(14-O-1278), § 2(Attach. B), 12-10-14;
Ord. No. 2014-22(14-O-1092), § 2-BB-i, 6-11-14;
Ord. No. 2019-15(18-O-1702), §§ 12, 13, 2-13-19;
Ord. No. 2020-58(19-O-1393), § 36, 10-28-20) Sec. 16-18O.029. Specific regulations for residential subareas.
1. In addition to those uses authorized in section 16-18O.005, a building or premises may be used for the following permitted uses and structures:
a. Eating and drinking establishments provided that no individual eating and drinking establishment exceed 5,000 square feet.
b. Establishments for the sale of convenience goods provided said use does not exceed
5,000 square feet.
c. Guesthouses and servant quarters.
d. Home occupation.
e. Laundry and dry-cleaning stores collection stations or plants, and laundry and dry cleaning establishments where
customers operate equipment provided said use does not exceed 2,000 square feet.
f. The use of a building or premises as a party house is expressly prohibited.
2. A building or premises may be used for the following permitted accessory uses and structures:
a. Repealed.
b. Off-street parking (minimum of 30 spaces).
c. Market gardens are limited to parcels that are used as schools, churches,
synagogues, temples, mosques and other religious worship facilities.
3. Site limitations.
a. Minimum building façade heights: 24 feet along each façade visible from the public right-of-way.
b. Maximum building heights: 225 feet along each façade visible from the public rightof-way.
4. Development controls. For nonresidential uses, floor area shall not exceed an amount equal to five percent of total built residential floor area.
5. Specific additional regulations for Subarea 5—Sydney Marcus West Residential. For
residential uses, floor area shall not exceed an amount equal to three and two-tenths times gross lot area.
6. Specific additional regulations for Subarea 6—Sydney Marcus East Residential. For
residential uses, floor area shall not exceed an amount equal to six hundred ninety-six-one thousandths times gross lot area.
7. Specific additional regulations for Subarea 7—Garson Residential. For residential uses, floor area shall not exceed an amount equal to one and forty-nine-one hundredths times gross lot area.
8. Specific additional regulations for Subarea 8—Lindbergh Residential.
a. Maximum permitted floor areas without bonuses. For residential uses, floor area shall not exceed an amount equal to one
and fifteen-one hundredths (1.15) times gross lot area.
b. Maximum permitted floor areas with bonuses (within areas defined on map attachment C. Lindbergh SPI-15 Subarea 8 master plan map):
i. For nonresidential bonus: None.
ii. For residential uses (open space and streets bonus): Floor area shall not
exceed an amount equal to two times gross lot area provided that for every one square foot of open space and streets built as shown on map attachment C*: Lindbergh SPI-15 Subarea 8 master plan map, up to two and
three-tenths additional square feet of buildings are permitted.
iii. For residential uses (affordable housing bonus): In the event a development has provided the maximum open space and street square footage in accordance with the Subarea 8 master plan map, floor area shall
not exceed an amount equal to two times gross lot area provided that affordable housing sales units or rental housing units comprise 20 percent of the portion of residential units that may be built after the maximum open space and street bonuses for the development are utilized.
iv. For combined bonuses: Under no circumstances shall the floor area of any development with bonuses exceed two times gross lot area.
9. The following uses are permissible only by special permit:
a. Special administrative permit:
1. Urban gardens as a principal use on an undeveloped lot.
(Ord. No. 2001-91, § 1, 7-11-01; Ord. No. 2004- 53, § 23C, 8-20-04; Ord. No. 2014-22(14-O-1092), §§ 2-BB-ii, 2-BB-iii, 6-11-14; Ord. No. 2020-58(19- O-1393), § 37, 10-28-20)
CHAPTER 16-18P. SPI-16 MIDTOWN
SPECIAL PUBLIC INTEREST DISTRICT
REGULATIONS*
Sec. 16-18P.001. Scope of provisions.
The regulations set forth in this chapter or set forth elsewhere in this part when referred to in this chapter, are the regulations for the SPI-16 Midtown Special Public Interest (SPI) District.
These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in section 16-18P.003, except as provided herein.
All attachments referenced in these regulations are attached to the ordinance adopting these regulations. Said ordinance, including all exhibits and attachments, is a public record available for public inspection in the office of the Atlanta Municipal Clerk. The ordinance is also available for public inspection on "final action legislation" link on the city council's website.
All existing categories of historic protection designated pursuant to Chapter 20 of part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this chapter.
Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. Whenever the following regulations conflict with provisions of part 16 other than historic protection regulations, the more stringent regulation shall apply.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22(23-O-1709), § 1, 6-26-24) Sec. 16-18P.002. Statement of intent.
The intent of the council in establishing and updating the SPI-16 Midtown Special Public Interest District is as follows:
1. Implement provisions of the Comprehensive Development Plan incorporating certain recommendations contained in studies of this area, including the initial comprehensive study known as Blueprint Midtown;
2. Implement provisions of subsequent supplemental plans and studies of this area including Blueprint Midtown II, Midtown Mile Market Overview & Retail Leasing Plan, Midtown Mile Market Research Study, Greenprint Midtown, I-75/85 Connector Transformation Study, Parking Study and Action Plan, Midtown Transportation Plan and Blueprint Midtown 3.0;
3. Create an urban environment where people can live, work, meet and play;
4. Encourage a compatible mixture of residential, commercial, cultural and recreational uses;
5. Improve the aesthetics of the built environment;
6. Facilitate safe, pleasant and convenient pedestrian circulation and minimize
conflict between pedestrians and vehicles;
7. Maximize opportunities for pedestrian amenities, including public art, safe accessible parks, plazas, and greenways for active and passive enjoyment;
8. Provide appropriately scaled, continuous pedestrian oriented uses and activities
adjacent to sidewalks along streets with identified pedestrian needs;
9. Provide a range of housing types and prices to meet different housing needs;
10. Preserve and protect Midtown's historic buildings and sites;
11. Encourage infill and rehabilitation development within traditionally commercial areas that include proportionately significant residential uses;
12. Provide for development compatible with existing surrounding residential areas
and provide for appropriate transitions between new development toward residential neighborhoods;
13. Encourage the use of MARTA through the location of mixed-use development around MARTA rail stations;
following attachments: A: "SPI-1 6 Zoning Boundaries" B:
"Conventional Streets and Pedestrian Ways"; C: "Street Typology"; and D: "Midtown Bonus Incentives". These attachments are incorporated herein by reference and are available for public inspection in city offices.
14. Minimize the amount of vehicular parking provided by encouraging shared parking and access along with alternative modes of transportation, while continuing to provide sufficient parking in an unobtrusive manner to surrounding
residential areas;
15. Encourage the increased use of alternative modes of transportation and mobility such as walking, biking, and public transportation.
16. Encourage opportunities for economic development where there is a planned
relationship between transportation systems and development.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22(23-O-1709), § 1, 6-26-24) Sec. 16-18P.003. Boundaries of district
established.
The boundaries of the SPI-16 Midtown Special Public Interest District are shown on Attachment A SPI-16 Boundaries Map which by this reference is incorporated into and made a part of this chapter. The Midtown Special Public Interest District is divided into three (3) subareas as shown on said Attachment A SPI-16 Boundaries Map. The subareas are described as follows:
Subarea 1: Midtown Mixed Use.
Subarea 2: Midtown Residential.
Subarea 3: Juniper East.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.004. Application procedures.
1. A special administrative permit (SAP) application and a specified number of copies each of a site plan, landscape plan, and elevation drawings of each exterior façade shall be submitted, as applicable, and approved by the office of zoning and development prior to filing for a building permit. All exterior demolition, new construction (including additions to existing buildings), new or expanded outdoor dining, or work which results in increased lot coverage, modification of the building footprint, or modification of building façades that would reduce the configuration of street facing openings, shall be subject to said SAP approval. All applications for a SAP shall be processed in accordance with the standards and procedures applicable to said SAP applications contained in chapter 25 of part 16 except as otherwise modified by this chapter 18P.
No SAP shall be issued until after such time any other required special use permit or board of zoning adjustment action has been obtained.
2. Administrative variations: As part of general action when plans require approval of an SAP, the office of zoning and development may authorize variations from regulations generally applying based on written findings, to be filed as a public record, that either:
a. A plan proposed by an applicant, while not strictly in accordance with regulations applying generally within the district, satisfies the public purposes and intent of such regulations, and provides public protection to an equivalent or
greater degree than strict enforcement of such regulations would provide; or
b. In the particular circumstances of the case, strict application of a particular regulation or regulations is not necessary for the accomplishment of public purposes or the provision of public protection, at that time or in the future.
c. Notwithstanding any provision in this chapter or part to the contrary, no
administrative variation shall be authorized for those listed in section 16-18P.005 for the board of zoning adjustments.
3. The office of zoning and development may exempt certain classes of applications for SAPs from detailed review requirements as set forth upon written findings that generally within these districts, the actions proposed are of such a character or scale as to make detailed reviews and approval unnecessary. Where applications for special administrative permits are determined by reference to such findings to be thus exempted, the permit shall be issued if otherwise lawful.
4. For the purposes of this chapter, a unified development plan approved under a single SAP and meeting all floor area ratio requirements, open space requirements, and off-street parking requirements, may be subdivided, even if the resultant parcels do not otherwise meet these requirements. Any changes from the approved SAP shall require a new or amended SAP, which shall be based on the geographic extent of the original SAP and shall meet floor area ratio requirements, open space requirements, and offstreet parking requirements of such; and shall indicate built or planned improvements on the original parcel(s). Where a single property owner no longer owns all parcels, the applicant shall obtain authorization from all property owners prior to permit submittal.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22(23-O-1709), § 1, 6-26-24) Sec. 16-18P.005. Permitted principal uses and structures.
1. The permitted principal uses and special uses set forth in Table 1: SPI-16 Midtown Table of Uses shall be permitted only as listed within each subarea with said table of uses shall be permitted only as listed within each subarea within said table of uses and only in the manner so listed. See also section 16-18P.014 for additional use location criteria.
2. Permitted principal uses. A building or premises shall be used only for the principal uses indicated with a "P" in Table 1: SPI-16 Midtown Table of Uses.
3. Special use permits. Special use permits shall be required as indicated with "SUP" in Table 1: SPI-16 Midtown Table of Uses. These uses are permissible subject to limitations and requirements set forth elsewhere in this chapter and in Section 16-25.001, et seq.
a. Eating and drinking establishments:
Location Size requiring Special Use Permit (SUP) East side of Peachtree St.
10,000 or more square feet Both fronting along the west side of Juniper St. & south of 10th St.
5,000 or more square feet Location Size requiring Special Use Permit (SUP) Both east of Juniper St. & north of 10th St.
5,000 or more square feet Both east of Juniper St. & south of 10th St.
2,000 or more square feet
b. Transfer of development rights: Transfer of development rights is permissible
provided meeting the following criteria in addition to those in section 16-28.023.
i. Both the sending and receiving properties must be located within SPI-16 whereas for purposes of section 16-28.023, properties shall be deemed to be closely proximate if
both lie within this SPI-16 District;
ii. The sending property must either be considered as new public parking per the table in section 16-18P.010 or new public park space per section 16-18P.010(3)(d) or designated under the city's historic preservation ordinance;
iii. Whenever the transfer of development rights regulations of this district is at variance with transfer
of development rights provisions established in section 16-28.023, the regulations of this district shall apply.
4. Board of zoning adjustments. The following are permissible only when approved by the board of zoning adjustments through variance or special exception, as applicable:
a. Outdoor amplified music:
i. Exception: Live entertainment shall be permitted with the following restrictions:
1. Live entertainment may only take place between 10:00 a.m.
— 8:00 p.m.
2. Live Entertainment, for the purposes of this chapter, does not include pre-recorded sound.
b. Alterations in transitional height planes or transitional yards.
c. Reduction or transfer of parking requirements for parcels east of Juniper Street whereas parking requirements may be
reduced and/or transferred off-site.
5. Prohibited uses and structures.
a. All uses marked with an "X" in Table 1:
SPI-16 Table of Uses shall be prohibited in the subarea(s) identified. All other
uses not listed in said Table 1: SPI-16 Table of Uses shall be considered prohibited in all district subareas.
b. Pedestrian bridges and/or tunnels.
c. Pedestrian colonnades and/or arcades oriented parallel to the closest street.
6. Use enclosure requirements.
a. Unenclosed outdoor displays of merchandise are prohibited in street furniture zones or clear zones.
b. When located within a supplemental zone, unenclosed outdoor displays of
merchandise must at the end of each business day be removed and placed inside a fully enclosed structure.
c. Veterinary use is allowed provided that the building is fully soundproofed (including an entry vestibule whereas only one set of doors can be opened simultaneously) and does not offer overnight boarding service.
7. Exclusions. No use or manner of operation shall be permitted which is obnoxious or offensive by reason of odor, smoke, noise, glare, fumes, gas, vibration, unusual danger of fire or explosion, emission of particulate matter, or interference with radio or television communication, or is otherwise incompatible with the character of the district.
Table 1: SPI-16 Table of Uses Permitted Uses and Structures P=Permitted Principal Uses & Structures SUP=Special Use Permit X=Not Permitted Subarea 1: Midtown Commercial Subarea 2: Midtown Residential Subarea 3:
Juniper East Banks/Financial Institutions P X X Barber Shops and Beauty Shops P P P Broadcast Telecommunication Towers P P P Business/Commercial Schools P X P
Childcare Centers P P P Places of Worship P SUP P Clubs/Lodges 5,000 s.f. or less P SUP P > 5,000 s.f. P X P Commercial Recreation P P P Data centers, except where any part of the property is within 2,640 feet of a highcapacity transit stop, as referenced in City Code Section 16-28.014(14).
P X X
Dormitories/Fraternities/Sororities P X X Eating and Drinking Establishments (per
size limitations in Sec. 16-18P.005(3.a)) other than Nightclub or Lounge
P/SUP P/SUP P/SUP
Defined as a Nightclub or Lounge in Chapter 10 (Alcoholic Beverages) (6,000 s.f. limit)
SUP SUP SUP
Exterior drive-through and drive-in facilities
X X X
Farmers Markets P P P Fuel service stations (certain locations only)
P 2
/X X X
Permitted Uses and Structures P=Permitted Principal Uses & Structures SUP=Special Use Permit X=Not Permitted Subarea 1: Midtown Commercial Subarea 2: Midtown Residential Subarea 3:
Juniper East Helicopter Landing Facilities SUP SUP SUP Hotels & Motels Lodging (*SA-3 less than 100
rooms)
P X P*
Institutions of Higher Learning P X X Laboratories and research facilities, including, but not limited to, wet labs and dry labs for scientific purposes, where the
character of operations and emissions byproducts does not create adverse effects beyond the boundaries of the facility
P SUP SUP
Laundry/Dry Cleaning (*2,500 s.f. limit) P* P* P* Market Gardens P P P
Museums/Galleries/Libraries P SUP SUP Nursing Homes/ Personal Care Homes / Assisted Living Facilities/ Rehabilitation Centers
SUP SUP SUP
Offices (other than Medical/Dental Office) P P P Medical/Dental Office P P P
Outdoor amusement enterprises, entertainment, music venues, meetings, or sales areas 90 days duration or less
SAP SAP SAP
90 days duration or more
SUP SUP SUP
Park-for-hire surface parking lots X X X Park-for hire parking structures SUP SUP SUP Printing P P P
Residential dwelling(s) P P P Retail Establishments P P P Professional/Personal Services P P P Public and Private Schools P X P Sales and Repair Establishments P P P Service Stations- including fuel (certain locations
only) P
3,4/ X X P4 / X
Shelters SUP X X Structures/Uses for MARTA P P P Supportive Housing P P P Telecommunication Switchboards/Etc. Data centers are excluded from this use in this district.
P X X
Urban Gardens P P P Veterinary (per criteria in Sec.
16-18P.005(6.c))
P P P
1 East of Spring St only.
2 West of W. Peachtree St only.
3 West of Spring St only.
4 Along Ponce de Leon only.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2-17; Ord. No. 2018-17(18-O-1070), §§ 1, 2, 6-13-18; Ord.
No. 2019-66(19-O-1504), § 14, 12-11-19; Ord. No. 2020-58(19-O-1393), § 38, 10-28-20; Ord. No.
2021-60(21-O-0682), § 36, 12-15-21; Ord. No. 2022-25(22-O-1496), § 1, 8-24-22; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24; Ord. No. 2024-36(24-O-1222), § 6, 9-4-24) Sec. 16-18P.006. Permitted accessory uses and structures.
Accessory uses and structures permitted within this district shall include those customarily accessory and clearly incidental to permitted principal uses and structures and specifically include clubhouses, pools (and other recreation amenities) pet amenities, bike parking and repair, auto parking to serve authorized uses, outdoor dining, exhibits and displays (without commercial sales transactions) and electric vehicle charging stations equipped with Level 1, Level 2, and/or DC Fast Charge EVSE.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.007. Subdivision including
zero-lot-line development.
In addition to the requirements of section 16-28.007, zero-lot-line subdivision is permitted for residential uses provided a minimum of 1,000 square feet in lot area is provided. Other subdivisions shall be allowed but shall not modify the determination of the primary sidewalk-level building façade(s) in section 16-18P.014.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.008. Redevelopment requirements.
Property shall be redeveloped in accordance with the requirements of this chapter when 60 percent or greater of the principal building on the property is removed or destroyed by any means. This shall be construed as follows:
1. Any paving or other accessory structural elements within any required transitional yard shall be removed and buffers
provided as required herein, notwithstanding any other provisions in part 16 to the contrary.
2. If no development is proposed concurrent with proposed demolition, all adjacent
rights-of ways shall be repaired to provide ADA accessible public sidewalks within
180 days of completion of demolition.
Further, within 18 months of the issuance of an SAP for such demolition, full streetscaping in accordance with section 16-18P.012 (including sidewalks and street trees) shall be installed.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22(23-O-1709), § 1, 6-26-24) Sec. 16-18P.009. Transitional height
planes, yards, fences and walls.
1. Transitional height planes.
a. No portion of any structure shall protrude through a height limiting plane beginning the specified number of feet above the point set forth in subsection
16-18P.009(1)(b) below and extending inward over the SPI-16 district at an angle of 45 degrees. The following districts shall be considered "protected districts" for purposes of this Section 16-18P.009(1):
i. R-1 through R-5;
ii. RG-1 and RG-2;
iii. MR-1, MR-2, and MR-MU; and iv. Landmark, Historic, PD, and SPI districts and district subareas having uses and densities predominantly like those permitted in the district classifications listed in subsections
(i) through (iii) above.
b. Proximity to districts and measurement applications:
i. For parcels in an SPI-16 district that are contiguous to a protected district, the transitional height plane shall be measured beginning 35 feet above the required SPI-16 setback or transitional yard adjoining the common property line with such protected district.
ii. For parcels in an SPI-16 district that are not contiguous to but are within 150 feet of a protected district, the transitional height plane shall
be measured beginning 15 feet above the nearest lot line of the protected district, provided this transitional height plane shall not extend more than 150 linear feet (measured along the ground) from the protected district up to and into the SPI-16 district. (See diagrams at section 16-29.001(62).
c. The purpose and intent of this provision is to provide protection for the named
protected districts from nearby looming structures regardless of the presence of an intervening public right-of-way or park or space, public or private street or alley, or any lot or parcel remnant.
d. Transitional height plane measurements shall be applied to parcels on a point-bypoint basis and not average grade.
2. Transitional yards and screening.
a. Yards. Where this district adjoins an R district, PD-H district, or SPI-17 (Subarea
4) district without an intervening street, a minimum 20-foot transitional yard is
required which shall not be used for the purpose of parking, loading, servicing or any other activity with the exception of private alleys or drives a maximum of
ten feet in width. Such yards shall be planted as approved by the city arborist and maintained as a landscaped strip.
b. Screening. Permanent opaque walls six feet in height shall be provided within
the transitional yard and shall be maintained in good condition.
3. Fences and walls located between the primary building and a side or rear lot line up to six feet in height may be erected. Barbed wire, razor wire, uncoated chain link fence or similar materials shall be prohibited.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2019-09(18-O-1581), § 10.13, 1-31- 19; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.010. Development controls.
Development shall comply with Table 2A entitled "SPI-16 Development Controls Table" and with subsections 1 through 7. Development shall be eligible for incentive(s) upon meeting the corresponding criteria set forth in Table 2B entitled "Bonus Incentives."
Table 2A: SPI-16 Development Control Table Midtown Mixed Use (SA #1) Midtown Residential (SA #2) Juniper East (SA #3)
FAR
(by right) Max FAR Bonus(es) See below Max FAR with Bonus(es)1 Juniper St. Transition Area Non-Juniper St.
Transition Area
FAR
(by right) Max FAR Bonus Max.
FAR
(with Bonus) FAR (by right) Max FAR (with Bonus)4 FAR (by right) Max FAR (with Bonus)4 Non-Residential FAR (times gross lot area)
5.0 5.2 10.2 On street level & street frontage On street level & street frontage 2,500 sf, max 5% residential floor area
2.0 0 2.0 Residential FAR (times gross lot area)
3.2 7.0 10.2 6.4 9.4 3.2 6.2 3.2 3.8 7.0 Max FAR 8.2 10.2 6.4 9.4 3.2 6.2 5.2 7.0 Minimum Façade
Height 24' 24' 24' Maximum Height None, except for transitional height plane2 adjacent to R
districts, PH-D or SPI 17-SA 4 400' 250' 100' (60' East of Piedmont Ave.)
Midtown Mixed Use (SA #1) Midtown Residential (SA #2) Juniper East (SA #3)
FAR
(by right) Max FAR Bonus(es) See below Max FAR with Bonus(es)1 Juniper St. Transition Area Non-Juniper St.
Transition Area
FAR
(by right) Max FAR Bonus Max.
FAR
(with Bonus) FAR (by right) Max FAR (with Bonus)4 FAR (by right) Max FAR (with Bonus)4 Side Yard Setback (Alleys permitted to 10' wide) None3 , except min. 10' for onsite residential uses with windows facing the side yard.
15' (of which 5' shall be landscaped) None2 , except 20' with
windows adj. to residential Rear Yard Setback (Alleys permitted to 10' wide) None3 , except min. 10' for onsite residential uses with windows facing the rear yard
15' 20' 1 The only exception to the Max FAR is via the provision of certain bonuses described below for either:
'Affordable Housing'; 'Buried Parking'; or 'Public Park'; or via a special use permit for the transfer of development rights per section 16-18P.005(3.b).
2 Transitional height plane begins 35' above the buildable area boundary and extends at a 45-degree angle away. See section 16-18P.009(1).
3 Subject to building code requirements.
Table 2B: Bonus Incentives Type Bonus Criteria Retail 2.0 FAR -New street-fronting, sidewalk level retail or eating and drinking establishment(s) with a minimum cumulative 2000 sq. ft. fronting on a type A street for a min. of 50% length of said façade.
Affordable Housing Residential: 3.0 FAR See Sec. 16-18P.010(3.b) below. This is the only Bonus Incentive applicable in Subarea 2.
Buried Parking 3.0 FAR - All on-site parking is located completely below sidewalk level(s) grade on all type A and B streets.
Transit Station Area 3.2 FAR - When located within a transit station area as identified on Attachment D Midtown Bonus Map, which by this reference is incorporated into and made a part of this chapter.
Public Parking 2.0 FAR -New parking structures with 400 or more spaces that are not used to satisfy the parking requirements for any on-site or off-site uses.
-Limited to one (1) such location for each eligible area on Attachment D Midtown Bonus Map.
-Meets the active use requirements of Section 16-18P.014(3).
-Provides standard signage indicating public parking.
-Shall be located a minimum distance of 1,000 feet from any
other site utilizing this bonus.
Reduced Parking 0.8 FAR -On-site parking provided less than 50% of the maximum parking allowed.
-May only be applied to parking spaces provided for on-site uses and may not be allowed to be applied to park-for-hire parking spaces.
Green Building 0.5 FAR -Professional documentation that all existing and new buildings in the project would achieve a minimum level of LEED Gold or equivalent.
-Utilizes non-potable water sources for 100% of outdoor water use.
-Demonstrates a 10% reduction of energy use in comparison to the City Energy Code requirements.
Type Bonus Criteria Connectivity 2.0 FAR - New infrastructure meeting the requirements of Sec.
16-18P.010(3.c).
-Documented perpetual easement or dedication recorded in the office of Superior Court, referenced to deed book with copy provided to the Office of Zoning and Development.
Building Reuse 1 s.f. reused = 2 s.f. bonus;
and Reused building does not count toward floor area -Eligible for either City Landmark, Historic or National Register of Historic Places designation.
Public Park 1 s.f. public park = 8 s.f.
bonus to a maximum 2.0
FAR
-Min. area of 20,000 square feet.
-Limited to one (1) such location for each eligible area on Attachment D Midtown Bonus Map.
-Meeting the design criteria in Sec. 16-18P.010(3.d).
-Shall be located a minimum distance of 1,000 feet from any other site utilizing this bonus.
1. Residential uses with more than 50 dwelling units shall: Provide a minimum of five percent of such total dwelling units as units having three or more bedrooms.
2. Attachment B Conventional Streets and Pedestrian Ways shall govern the following:
a. New conventional streets and new pedestrian ways shall be constructed as shown in Attachment B in order to create pedestrian and vehicular connectivity.
b. New conventional streets created per Section 16-18P.010(2.a) above, shall meet the requirements of Section 16-18P.010(3.c) below.
c. All other regulations within this district applicable to streets and street frontages shall be applied to the new conventional streets and new pedestrian ways required in Attachment B.
d. The area of any such new conventional streets or new pedestrian ways shall be allowed to be included in the net or gross area calculation for density purposes and shall be afforded a density bonus as specified in section 16-18P.010(3.c) below.
3. Density bonus opportunities.
a. Whenever the affordable housing provisions of this district are in conflict with affordable housing established in section 19-1006, the regulations of this district shall apply.
b. Affordable housing, for the purposes of this chapter, shall mean:
i. An affordable rental unit that is actively marketed for lease to households having an income, as certified by the prospective tenant(s) at the time of execution of the applicable lease agreement, that does not exceed 60 percent AMI or 80 percent AMI, as applicable, adjusted for household size, for the AtlantaSandy Springs-Marietta, Georgia HUD Metro Fair
Market Rent Area (as published by HUD as of the date of the tenant's application). The monthly rent amount (not including utilities and mandatory fees) for each affordable workforce housing unit shall
be no more than 30 percent of the household's monthly gross income as published periodically by HUD; or ii. Developments containing
residential uses shall be eligible for the floor area ratio (FAR) bonus set forth in Table 2B for its respective subarea, provided that either:
1. At least 10 percent of the bonus FAR shall be devoted to on-site affordable housing provided for households at 60 percent
of area median income
(AMI);
2. At least 15 percent of the bonus FAR shall be devoted to on-site affordable housing provided for households at 80 percent
of area median income (AMI); or
3. In-lieu of compliance with the on-site affordability requirement, the Applicant elects to pay an in-lieu fee to the City calculated as set forth in subsection 16-18P.010(3)(b)(vii).
In addition to the above each of the following criteria shall be met, where applicable:
iii. Affordable requirements shall be in place for a minimum of 30 years from the date of issuance of the occupancy permit and shall include deed restrictions governing the resale value or rental rate placed on the
affordable units.
iv. Parking for all such affordable dwelling units shall be leased or sold separately from the rental or purchase price for such units for the life of the unit such that the renter or purchaser has an option to have the unit priced lower than if the price of the unit and parking space were combined.
v. No temporary or final certificate of occupancy shall be issued until such time as:
1. A recorded land use restrictive covenant (LURA) or land use declaration, as applicable, in the form provided by the City, is recorded in the Fulton County real estate records, establishing that the affordable housing requirements are
met; or
2. The Office of Buildings has verified that the full in-lieu fee has been collected.
vi. Applicant may elect to partially or fully satisfy the criterion set forth in subsection 16-18P.010(3)(b)(2)(ii) by leasing affordable units to Housing Choice Voucher recipient households, regardless of their
household income. Each unit leased to a Housing Choice Voucher recipient household shall count as one unit provided at the 80 percent AMI range unit set-aside. Units occupied by Housing Choice Voucher households may not be used to satisfy the 60 percent AMI range unit set- aside.
vii. Applicant may elect to satisfy subsection 16-18P.010(3)(b)(ii) by paying a fee to the City in lieu of compliance with the on-site affordability requirement. In-lieu fees are a public record and calculated yearly to
reflect the current market.
Rates will be published and made available on the City of Atlanta Department of City Planning website no later than June 1 of each year and will be effective July 1 of that same year. The in-lieu fee plus administrative costs are based on the approximate cost of construction of replacement affordable workforce housing units that were not built on site. Fees collected shall be deposited into a trust fund to support the production and preservation of affordable housing within the Midtown Special Public Interest District.
viii. The percentage mix of affordable studio, one bedroom, two bedroom, and three-bedroom
units shall be proportionally similar to the percentage mix in the overall development.
c. Connectivity: Shall only be established via new conventional streets, shared streets, mid-block passages, or alleys, and shall be designed to meet the following criteria:
i. For new public or private conventional streets: A minimum 40' width without gates or similar barriers including a minimum of two travel lanes and along both sides of
the street: granite curbing, sidewalk street furniture zones at a minimum width of three feet and sidewalk clear zones at a minimum width of five feet.
ii. For new public or private shared streets: A minimum 20-foot width paved surface for pedestrians and/or vehicles without gates or similar barriers.
iii. For new public or private pedestrian ways: A minimum 20-foot width including a minimum 10-foot-wide pedestrian-only pathway.
iv. For new public or private service streets: A minimum 20-foot width utilized for vehicles only.
d. Public park space. Shall be designed to meet the following criteria:
i. Shall provide active and/or passive recreational amenities visible and accessible from any point along 90 percent of any
adjacent sidewalk.
ii. Shall permit and encourage pedestrians to walk on a minimum of 80 percent of the surface of the parcel excluding fountains, pedestrian furniture, public art and similar elements.
iii. Shall be designed in accordance with the requirements for supplemental zones in section 16-18P.013.
iv. Shall be open to the public during all daylight hours.
v. Shall be continuously well maintained by a designated agent for such maintenance.
4. Façade materials. Exterior Insulation Finishing System (EIFS) is not allowed.
5. Roofing. All building and structural roofs shall be constructed of a heat-reflective material to achieve a minimum initial
Solar SRI of 78 for a low-sloped roof (less than or equal to 2:12) and a minimum
initial SRI of 29 for a steep-sloped roof (more than 2:12) except for those portions of roofing designated for vegetation.
6. Bridges and tunnels prohibition.
Pedestrian bridges and tunnels are prohibited when located above public streets or private streets which function as public streets.
7. Utility location. Along existing and new type A and B streets shown on attachment B utilities within a sidewalk or supplemental zone shall be located below ground, provided that such utility is not in violation of the policies of utility
regulated by the public service commission or otherwise regulated by state law and/or franchise agreement.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2018-17(18-O-1070), §§ 2.1, 8, 6-13- 18; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24;
Ord. No. 2025-24 (24-O-1581), § 1.A, 7-7-25) Sec. 16-18P.011. Open space requirements.
1. Required open space. The minimum required open space, as defined in section 16-18P.011(2), shall be a percentage of the gross lot area (GLA) and as set forth in Table 3: SPI-16 Open Space Table below. In the case of a mixed-use development the required open space shall be the greatest square footage of open space applicable to that particular component so that any lesser square footage of open space of any other component does not apply.
2. For the purposes of this chapter, open space shall be defined as set forth in section 16-28.010(5.a) except that balconies for residential units above sidewalk-level shall not count toward open space. Any of the following may count as open space:
a. Any supplemental zone area(s) which meet section 16-18P.013;
b. Any new streets, new pedestrian paths or shared vehicular access which meet
the criteria of section 16-18P.010(3.c);
c. Any sidewalk level public park space per the criteria of section 16-18P.010(3.d);
d. Any portion of a low-sloped roof (less than or equal to 2:12) designed for
vegetation;
Table 3: SPI-16 Open Space Table Subarea 1: Midtown Commercial Subarea 2: Midtown Residential Subarea 3: Juniper East Residential & Lodging Uses 20% 25% 25% Non-Residential Uses (Commercial & Retail Uses) 15% 20% 20% Non-Residential Uses (All Other Uses) 10% 15% 15%
3. Open space incentives.
a. Public art. Sidewalk level public art shall be eligible for an open space bonus in the amount of ten square feet for every square foot of the public art area, up to a
maximum of 10,000 square feet of open space bonus, provided that the public art is:
i. A minimum of 100 square feet in size and provides a level surface (less than a one percent slope) that is visible and accessible from any adjacent sidewalk or public park;
and ii. Programmed to provide for daily 3-D public art in coordination with the City's Office of Cultural Affairs.
b. Public park space. Sidewalk level public park space with a minimum size of 5,000
square feet and otherwise meeting the criteria of Section 16-18P.010(3.c) shall be eligible for an open space bonus in the amount of four square feet toward meeting the open space requirement for every square foot of public park space provided.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2018-17(18-O-1070), § 3, 6-13-18;
Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.012. Sidewalks.
Public sidewalks shall consist of two zones: a street furniture zone and a clear zone. Each zone shall be located along all public streets as set forth in Table 4: SPI-16 Sidewalk Table and is subject to the following:
1. Street furniture zone requirements. Said zone shall be continuously located
immediately adjacent to granite curbing and shall meet tree planting requirements of section 16-18P.012(2). The area between such tree planting areas shall
either be planted with evergreen ground cover such as mondo grass or a liriope species or shall be constructed in accordance with the Midtown Streetscape Plan. Right-of-way dining may be allowed in the street furniture zone
provided securing such a valid permit from the Atlanta Department of Transportation "ATLDOT". In addition, this zone may be used for street furniture specified by the office of zoning and
development in coordination with ATLDOT and accordance with the Midtown Streetscape Plan. This furniture may include trash receptacles, traffic
signs, bus shelters, bicycle racks, benches, tree fencing, and utility poles (where
allowed) or similar elements in accordance with uniform design standards utilized
for the placement of such objects in the public right-of-way in a manner that
does not obstruct pedestrian access or motorist visibility.
2. Street tree requirements. Street trees are required to be planted within the street furniture zone spaced equidistant between street lights as specified in the Table 4:
SPI-16 Sidewalk Table above and in accordance with the Midtown Streetscape Plan. All newly planted trees shall be a minimum of three inches in caliper
measured 36 inches above ground, at a minimum of 12 feet in height and limbed up to a minimum height of seven feet.
Trees shall have a minimum planting area of 40 square feet planted with evergreen ground cover such as mondo grass or a liriope species. All plantings, planting replacement and planting
removal shall be approved by the city arborist. Tree grates are prohibited and tree fences shall only be allowed along
Peachtree Street.
3. Street light requirements. Street lights that meet a standard Atlanta type as
approved by the office of zoning and development are required to be installed within the street furniture zone spaced
equidistant between required street trees as specified in the Table 4: SPI-16
Sidewalk Table above and in accordance with the Midtown Streetscape Plan.
4. Clear zone requirements. Said zone shall be continuous standard concrete hardscape located immediately contiguous to the street furniture zone at widths specified in the Table 4: SPI-16 Sidewalk Table above. Said zone shall be
unobstructed by any permanent element to a minimum height of ten feet. Where property within this district abuts another district without an intervening street,
the sidewalk shall taper as necessary to provide a smooth transition to the abutting district sidewalk. If the abutting district has no existing sidewalk, the
sidewalk shall taper to a width of six feet.
5. Nothing shall be erected, placed, planted, or allowed to grow in such a manner as to impede visibility within visibility triangles at street intersections between the heights of 2 feet and eight feet above grade.
See also section 16-28.009: Visibility at Intersections.
6. Outdoor dining within the street furniture and clear zones: Right of Way Dining
may be allowed in the street furniture zone provided securing such a valid permit from ATLDOT, Outdoor dining may
encroach into the clear zone provided the following criteria are met:
a. Peachtree Street shall have a minimum 12 feet of unobstructed clear zone area adjacent to the curb.
All other streets shall have a minimum eight feet of unobstructed clear zone area adjacent to the curb;
b. No permanent structure or ornamentation shall be located within the encroachment area and no element shall be attached to the sidewalk in any way; and
c. At such time the outdoor dining use is discontinued, sidewalks shall comply with all requirements of this chapter.
Table 4: SPI-16 Sidewalk Table Peachtree Street Cypress Street,
Peachtree Walk All Other Streets in SA-1 & 3 All Other Streets in SA-2 Min. Street Furniture Zone Width 5' Varies (5'—20') 5' 5'
- Street Tree Planting Standards 40' on-center Varies 30' on-center 30' oncenter
- Street Lighting 40' on-center Varies 60' on-center 60' oncenter Min. Clear Zone Width 15' Varies (10'—15') 10' 10' Min. Setback (from street curbing) 50' north of 14th St.
25' south of 14th St.
20' 15' 15' Min. Supplemental Zone width 30' north of 14th St./
5' south of 14th St.
5'/0' 1 5'/0' 1 5' Max Street Facing Setback (from curb) - except for public parks and public art areas per Sec. 16- 18P.011(3).
70' north of 14th St./ 50' south of 14th St.
40' 30' 30' 1 5' min. supplemental zones for either 1) streets classified as an 'A' street in Attachment C Street Typology, which by this reference is incorporated into and made a part of this chapter; or having street fronting, sidewalk level residential units; otherwise no supplemental zone is required.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2-17; Ord. No. 2018-17(18-O-1070), § 4, 6-13-18; Ord.
No. 2020-33(20-O-1381), § 28, 6-23-20; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.013. Supplemental zone.
For purposes of these regulations, the area between a sidewalk and in line with any building façade, or parking lot when no intervening building exists, shall be defined as the supplemental zone. Supplemental zones shall meet the widths as specified in the Table 4: SPI-16 Sidewalk Table above and the following requirements:
1. When sidewalk level residential units are provided the supplemental zone shall be landscaped with the exception of terraces, porches, stoops, stairs and walkways;
2. When sidewalk level eating and drinking establishments are provided along A1
and A2 streets as set forth in Table 5:
SPI-16 Street Activation Table, outdoor dining shall be provided and shall include tables, seating, and shading and thereafter maintained for outdoor dining use;
3. The supplemental zone shall be no more than 30 inches above finished grade,
unless existing topographical considerations render this requirement unreasonable;
4. Walls, as defined in Section 16-29.001(25), shall not be allowed between the street
and any building except for retaining walls which shall be no more than three feet in height unless existing topography requires retaining walls of a greater
height;
5. Fencing and similar barriers, as defined in section 16-29.001(25), shall only be
permitted up to 42 inches in height (including any plant material) in a supplemental zone only for either sidewalk level residential uses or to separate
authorized outdoor dining. Such outdoor dining may only be separated by nonfixed fencing (or similar barriers or movable planters). Other fencing is otherwise prohibited when located between the
street and any building; and
6. Within Midtown Residential Subarea 2:
Supplemental zone(s) shall be planted with tree(s) having a minimum mature height of 40 feet spaced at maximum 60 linear feet of street fronting property line(s) as approved by the city arborist.
7. Supplemental zones and sidewalk level open spaces over 5,000 SF (except those
adjacent for Places of Worship and Museums/Galleries/Libraries) shall include electricity, seating, and shading elements.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.014. Relationship of building to street.
1. For purposes of this chapter, sidewalk level shall be defined as any floor of a building with a finished-floor elevation less than or equal to five feet above and below the adjacent sidewalk (or street if no sidewalk is existing).
2. Building floors shall be delineated from the third story above sidewalk level down to each sidewalk level and shall be executed through windows, belt courses, cornice lines and/or similar architectural detailing.
3. General sidewalk level building façade requirements:
a. All buildings shall have a minimum 24-foot façade height along the public right-of way and shall have a minimum of one building façade meeting the primary sidewalk-level building façade requirements of this Section;
b. Active uses along existing and new streets shall be provided as delineated in Table 5: SPI-16 Street Activation Table, to a
minimum depth of 40 feet for nonresidential uses and 20 feet for residential uses beginning at any sidewalk level
street facing building façade to a minimum height of 20 feet above sidewalk level
except when topographical conditions prevent such treatment. These active uses shall be internally illuminated and serviced by plumbing, heating, and
electricity and are limited to uses set forth in Table 5: SPI-16 Street Activation Table, with the following exceptions which also shall be allowed:
i. Fire command and transformer (or similar electrical) rooms, each not exceeding ten feet of street fronting façade length. For parcels with more than one street frontage, such room(s) shall be located on the lesser classified street(s) according to Attachment C Street Typology Map;
and ii. Structures required for public transit;
c. The primary street fronting pedestrian entrance for sidewalk level uses:
i. Shall face, be visible and be accessible with a push button activator seen from the clear zone sidewalk
connected with a minimum of five feet wide pedestrian walkway; and ii. Shall have a minimum six-inchhigh street address located directly near the primary building entrance
clearly visible from the sidewalk;
d. Residential uses which do not have street frontage shall be linked to the public
sidewalk with a minimum four feet wide pedestrian walkway.
e. Accessory residential uses (such as lobbies, clubhouses, mail rooms and similar) at the sidewalk level along type A streets shall be limited to the greater of either:
40 feet of street frontage; or 50 percent of the overall street fronting façade length.
Any bike room shall be located on the lesser classified street(s) according to Attachment C Street Typology Map and
limited to 20 feet of such street frontage length.
4. Fenestration requirements. Street-fronting sidewalk level building façades, except places of worship, fire stations & MARTA uses, shall meet the following requirements:
a. Length. Fenestration and entrances shall be provided for a minimum of the
horizontal length of each street-fronting sidewalk-level façade, as designated in
the Table 5: SPI-16 Street Activation Table. The length of façade without intervening fenestration or entryways shall not exceed 20 feet;
b. Surface treatment and visibility. Windows and door glass shall utilize clear glass or tinted glass. Tinted glass shall have a
transmittance factor of 50 percent or greater and shall have a visible light reflectance factor of ten or less having visibility into the building for a minimum depth of ten feet as measured from the
interior windowpane. Painted glass, reflective glass or other similarly treated or opaque windows are prohibited.
c. Non-residential uses. Fenestration and entrances shall be-measured beginning
at a point not more than 36 inches above the required sidewalk to a height at least ten feet above said sidewalk unless:
i. When the finished floor elevation is 36 or more inches above the sidewalk:
Beginning at the finished floor elevation to a height at least ten feet above the finished floor elevation;
or ii. When the finished floor elevation is below said sidewalk: Beginning at a
point not higher than six inches above the adjacent sidewalk to a height at least ten feet above the finished floor elevation.
d. Residential uses. Fenestration and entrances shall have windows at a minimum of four feet in height.
Table 5: SPI-16 Street Activation Table Street Typology Location Permitted Active Uses (as further regulated in Table 1: SPI-16 Table of Uses) Min. Fenestration (as % of street level façade) A1 Street Peachtree St from 5th St to 15th St Places of worship, Eating & Drinking Establishments, Hotels & Motels1
, Multi-family/ Duplexes/ Single-Family Dwellings1 , Museums/Galleries/Libraries, Offices1 , Medical/Dental Office1 , Retail Establishments 75% for all uses A2 Street North Ave, 5th St, 10th St, 12th St from Williams St to Juniper St,
14th St from Williams St to Juniper St, 17th St, Spring St from North Ave to 17th St, West Peachtree St from North Ave to 17th St, Crescent Ave, Peachtree St from North Avenue to 5th St, Peachtree St from 15th St to I-85 All uses allowed on type A1 Streets, Banks/Financial Institutions, Barber Shops & Beauty Shops, Business/Commercial
Schools, Childcare Centers, Clubs/ Lodges, Commercial Recreation, Institutions of Higher Learning, Laboratories and Research Facilities, Laundry/Dry Cleaning, Professional/ Personal Services, Public & Private Schools, Sales &
Repair Establishments, Veterinary 65% of all uses Street Typology Location Permitted Active Uses (as further regulated in Table 1: SPI-16 Table of Uses) Min. Fenestration (as % of street level façade) B1 Street Juniper St from 13th St to 14th St and Juniper St from North Ave to
10th St All uses allowed on type A Streets, Dormitories/Fraternities/Sororities, Nightclub/Lounge, Fuel Service Stations, Mortuary/Funeral Homes, Nursing Homes/ Personal Care Homes/Assisted Living Facilities/ Rehabilitation Centers, Printing, Service Stations, Shelters, Supportive Housing 50% for nonresidential uses,
30% for residential uses B2 Street Ponce De Leon Ave, 3rd St, Biltmore Pl, 6th St, 7th St, Peachtree Pl, 12th St from Juniper St to
Piedmont Ave, 14th St from Juniper to Piedmont Ave, 15th St from Spring St to Peachtree Cir, Spring St from 17th to Peachtree St, West Peachtree St from 17th St to Peachtree St, Beverly Rd to Inwood Cir, Peachtree Walk from 10th St to 13th St, Cypress St from 3rd St to Peachtree Pl, Piedmont Ave from Ponce de Leon Ave to 3rd St C Street Other existing streets not listed Active Uses not required 30% for all 1 Limited 40 feet of street frontage for each use, provided that the sum of all such uses shall not exceed 50 percent of the overall street fronting façade length along a type A1 street.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2-17; Ord. No. 2018-17(18-O-1070), § 5, 6-13-18; Ord.
No. 2022-25(22-O-1496), § 2, 8-24-22; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.015. Signage.
Refer to section 16-28A: Sign Ordinance.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2018-17(18-O-1070), § 5, 6-13-18;
Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.016. Lighting and storefront illumination.
1. All lighting, including all parking decks, surface parking lots and lit canopies shall reduce light spillage onto adjacent properties by providing cutoff luminaries which have a maximum 90-degree illumination. See also section 16-18P.020.
2. All lighting that up-lights trees, buildings or other elements shall be located a minimum height of eight feet above an adjacent sidewalk level when not located within completely landscaped areas.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.017. Off-street loading requirements.
The off-street loading requirements for this district are as shown in the table of loading requirements, section 16-28.015, off-street loading requirements. See section 16-18P.018 below for screening requirements.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2019-09(18-O-1581), § 4.E, 1-31-19;
Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.018. Dumpster and loading
areas, loading dock entrances and building mechanical and accessory features.
1. Dumpsters and trash areas. Dumpsters and trash areas shall be screened so as not to be visible from any public plaza, outdoor dining area, public sidewalk or public right-of-way and if otherwise visible shall be enclosed with opaque walls six feet in height.
2. Loading areas.
a. Loading areas shall be screened so as not to be visible from any public plaza, outdoor dining area, public sidewalk or public
right-of-way with the exception of hotel uses. Hotel uses may utilize on-street
loading if orientated predominately parallel to the adjacent right-of-way and located fully outside any existing public driving lane and at least partially on private
property at a maximum length of 60 feet as permitted by ATLDOT.
b. Loading dock entrances shall be screened so that loading docks and related activity are not visible from the public right-ofway when not in use.
3. Building mechanical and accessory features.
Shall be in the location of least visibility from the public right-of-way. If located to the side or rear of the principal structure, screening with plant or fence materials shall be required. When located on rooftops, said features shall be incorporated in the design of the building and/or screened with building materials similar to those of the building.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2020-33(20-O-1381), § 29, 6-23-20;
Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.019. Curb cuts and parking
structures.
1. Sidewalks at curbcuts and driveways. All sidewalk paving materials shall be continued across any intervening driveway. On each side of such a continuous sidewalk a band of textured concrete shall be provided located both in-line with and equal in width to the street furniture zone and in-line with the supplemental zone or building façade at a minimum five feet width.
2. Curbcut restrictions. No vehicular entrances to properties with frontage on the east side of Peachtree Street shall be located on other public streets which connect Peachtree Street to the Ansley Park neighborhood. Otherwise, except for hotel uses, curb cuts shall be allowed only as follows:
a. For a parcel with only one street frontage: maximum one curbcut.
b. For a parcel with two or more street frontages: maximum two curbcuts, both located on the lesser classified street(s) according to Attachment C Street Typology Map. If the two streets have the same classification such curbcut(s) may
be on either street.
3. Curbcut widths. Curb cuts shall be limited in width at the sidewalk to 12 feet for one-way entrances and 24 feet for two-way entrances, unless a greater width is approved by ATL DOT upon its finding of necessity of such a greater width.
4. Driveway and vehicular services configuration.
a. Driveways shall be predominantly perpendicular to any adjacent street, except for hotel uses which may have circular drives for the purpose of drop-off and pick-up. Driveways parallel to the
street are prohibited between the street and a building.
b. Gasoline fuel dispenser structures and associated vehicular services such as air pumps and car washes shall not be located between a building and the street.
c. Drive-through and drive-in facilities shall be prohibited.
5. Drop-off lanes. No drop-off lanes shall be permitted along public streets except for hotel uses as approved by ATLDOT.
6. Parking orientation. Entrances to garages and carports that serve one or more contiguous sidewalk-level residential units only shall share one common drive with any garages and carports facing rear or side yards having no street frontage.
7. Parking structure public screening. In addition to section 16-28.028, parking structures shall have the following additional requirements:
a. At a height of 36 feet or less above finished grade which faces any public or private street shall meet section
16-18P.014(3)(b) to provide an intervenZONING § 16-18P.019 ing building having conditioned habitable space along the length of such parking structure;
b. At a height of 36 feet or more above finished grade which faces any public or private street shall provide either:
i. An intervening building at average depth of 20 feet having conditioned habitable space along the length of such parking structure; or ii. All openings of the parking structure shall be fully screened from view
from adjacent public or private streets so that cars, sloped ramps, and interior deck lighting are not visible from adjacent streets. In addition, along type A and B streets, the façade design of said parking
structure shall be compatible with the principal building in terms of architectural style, texture, quality, and material;
c. Side or rear yard facing parking deck façades that are exposed and visible from a public street, shall screen such visible portions of the parking deck utilizing the parking deck screening regulations
provided in section 16-28.028(1)(b)(ii).
8. Parking structure buffers. Along non-street facing sides of parking structures a minimum ten feet wide continuous landscaped strip shall be provided between the structure and the property line(s). This landscaped strip shall be planted with a combination of trees with evergreen ground cover such as mondo grass, liriope species, ivy, or shrubs with all plantings to be approved by the city arborist.
9. Public parking signage. Parking facilities providing either public parking spaces or more than 50 park- for-hire parking spaces shall provide standard signage indicating public parking in accordance with the Midtown standard in
coordination with ATL DOT.
10. Shared access. Notwithstanding the provisions of section 16-28.006(10), a common or joint driveway may be authorized when adjacent lots have direct vehicular access to a publicly accessible street and a perpetual easement agreement is agreed upon by all affected property owners and included in the SAP application.
11. Pedestrian walkways from parking. All sidewalk level parking, including parking decks, shall have walkways a minimum width of four feet connecting such parking to the public sidewalks and to building entrances.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17Ord. No. 2018-17(18-O-1070), § 6, 6-13-18;
Ord. No. 2020-33(20-O-1381), § 30, 6-23-20; Ord.
No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.020. Vehicular off-street parking requirements.
In addition to the provisions of section 16-28.008(7), sections 16-28.013 and 16-28.014), the vehicular parking requirements set forth in Table 7: SPI-16 Off Street Parking Requirements shall apply and are further subject to subsections 1 through 5 below:
Table 7: SPI-16 Vehicular Off-Street Parking Requirements Use Minimum Spaces Maximum Spaces
Banks, business colleges, clubs & lodges, printing.
None 6.5 / 1,000 s.f.
Dorms, fraternities, sororities None 1.0 per each 2 bedrooms Eating & Drinking
Establishments -Indoor and Outdoor (east of Juniper) 1 / 300 s.f. 8.0 / 1,000 s.f.
Hotels & Motel Lodging None 1.0 per lodging unit Medical Office None 3.5 / 1,000 s.f.
Nursing homes, convalescent homes, and similar care facilities None 1.0 per each 4 bedrooms Office None 2.0 / 1,000 s.f. (may be shared with other uses)
Use Minimum Spaces Maximum Spaces Residential None 1.1 per 1 bedroom and 2.1 per 2+ bedrooms
Retail (east of Juniper) 1 / 300 s.f. 6.5 / 1,000 s.f.
Shelter 1 per each on-duty staff member, plus 1.0 / 2,000 s.f.
1 each for first 2 bedrooms, plus 0.5 for each of 3 or more bedrooms plus 1/3 for each dwelling unit Other non-residential uses except as specified in part 4 below.
None 3.5 / 1,000 s.f.
All non-residential greater than 25,000 sf Must provide a transportation management plan (TMP) including commitment of TMA support.
Note: All car share or carpool/vanpool (or similar) spaces shall not count toward the above parking criteria.
*Unbundling: Parking for all residential dwelling units may be leased or sold separately from the rental or purchase price for the life of the unit such that the renter or purchaser has an option to have the unit priced lower than if the price of the unit and parking space were combined.
1. Off-street surface parking.
a. Shall not be located closer to a street than any on-site building façade and shall not occupy more than 50 percent of any street frontage parcel length;
b. Shall be prohibited from being located within 30 feet of the back of the public sidewalk located along an "A" classified street.
c. Shall be accessory to a permitted principal use only, provided that parking spaces serving another principal permitted use may use such facility for shared parking as specified in section 16-18P.020(5) below.
d. Park-for-hire surface parking lot(s) as a principal use are prohibited.
2. Parking structures. Parking spaces provided in excess of the parking requirements of this section 16-18P.020 shall only be allowed as park-for-hire spaces
located within a parking structure. Said excess spaces shall be considered a
principal use and shall first require a special use permit as authorized in section 16-18P.005. Otherwise, when the number of parking spaces does not exceed the requirements of this Section, said
spaces shall be permitted to be used as park-for-hire parking decks without a special use permit.
3. Electric vehicle charging stations. All parking facilities shall include electric vehicle charging stations, or similar alternative fuel facilities, in a ratio of at least one station for every 20 automobile parking
spaces. Each electric vehicle charging station shall provide Level 2 or Direct Current Fast Charging connections for one or more parking spaces. See also criteria in section 16-28.017.
4. For specific non-residential uses.
a. Child care centers, day care centers, pre-kindergartens, play and other
special schools or day care centers for young children: Such establishments shall provide safe and convenient facilities for loading and
unloading children, as approved by
ATL DOT.
b. Schools, colleges, places of worship, recreation or community centers and
other places of assembly. A minimum of one space for each six fixed seats with 18 inches if bench length counted as one seat or one space for each 50 square feet of enclosed floor area for the accommodation of movZONING § 16-18P.020 able seats in the largest assembly
room, whichever is greater, plus the following maximums:
i. Public or private elementary or middle school: Two spaces for each classroom.
ii. High school. Four spaces for each classroom.
iii. Colleges and universities: Eight spaces for each classroom.
5. Parking, lighting, security, landscaping and maintenance. All surface parking
lots and structures, whether a nonconforming principle use or accessory use, shall meet the following requirements:
a. Lighting shall be provided throughout all parking facilities to equal a minimum of one-half footcandle of light. For parking structures at points of ingress and
egress such lighting shall be a minimum of one footcandle of light.
Where applicable, public street and other ambient lighting may be utilized to either partially or totally fulfill these lighting requirements;
however, if removed it shall be required to independently provide these required levels of illumination.
b. Surface parking lots: The requirements of City of Atlanta Chapter 158 Vegetation, Article II Tree
Protection, Section 30 Parking lot requirements shall apply to this district regardless of the size of the lot.
c. Parking facilities shall be maintained in a clean, safe and sanitary condition with parking spaces and driving lanes clearly defined and maintained. See also section
16-28.014 for additional requirements.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2018-17(18-O-1070), §§ 7, 9, 6-13- 18; Ord. No. 2020-33(20-O-1381), § 31, 6-23-20;
Ord. No. 2022-44(22-O-1535), § 3, 12-14-22; Ord.
No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.021. Minimum bike parking.
See section 16-28.014(6), Bicycle parking requirements.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2018-17(18-O-1070), § 10, 6-13-18;
Ord. No. 2019-09(18-O-1581), § 12, 1-31-19; Ord.
No. 2024-22 (23-O-1709), § 1, 6-26-24) Sec. 16-18P.022. Office uses additional requirements.
1. Showering facilities. All office buildings containing over 25,000 square feet of gross office space shall provide showering facilities including showers and lockers, in a ratio of at least one showering facility for every 25,000 square feet of gross office space, available to all building tenants and their employees, provided that no building shall be required to exceed a maximum of eight showering facilities.
2. Transportation management plans. The office of buildings shall not issue any certificate of occupancy permits for any multi-family residential, office, or hotel development (including the sum of such uses in combination) having more than 25,000 square feet of gross floor area until such time the developer or their specified agent has submitted to the office of zoning a transportation management plan (TMP). This TMP shall contain strategies to reduce single occupancy vehicle trips generated by the project and shall be in accordance with the Transportation Management Plan Development Guide, a document maintained by the Atlanta Department of Transportation.
3. A summary report of ongoing implementation of the TMP shall be submitted annually.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2- 17; Ord. No. 2021-10(20-O-1723), § 4, 3-10-21;
Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24)
CHAPTER 16-18Q. SPI-17 PIEDMONT
AVENUE SPECIAL PUBLIC INTEREST
DISTRICT REGULATIONS*
Sec. 16-18Q.001. Scope of provisions.
The regulations set forth in this chapter or set forth elsewhere in this part when referred to in this chapter, are the regulations for the SPI-17 Piedmont Avenue Special Public Interest (SPI) District. These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in Section 16-18Q.003, except as provided herein.
All attachments referenced in these regulations are attached to the ordinance adopting these regulations. Said ordinance, including all exhibits and attachments, is a public record available for public inspection in the office of the Atlanta Municipal Clerk. The ordinance is also available for public inspection on "final action legislation" link on the City Council's website.
All existing categories of historic protection designated pursuant to chapter 20 of Part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this chapter.
Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. Whenever the following regulations conflict with provisions of Part 16 other than historic protection regulations, the more stringent regulation shall apply.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.002. Statement of intent.
The intent of the council in establishing and updating the SPI-17 Piedmont Avenue Special Public Interest District as a zoning district is as follows:
1. Implement provisions of the Comprehensive Development Plan incorporating certain recommendations contained in studies of this area including the 2016 comprehensive study known as Midtown Garden District Master Plan;
2. To provide, through the administration of specific standards and criteria, that new development achieves architectural,
site and street design consistent with the existing historic built environment;
3. Improve the aesthetics of the built environment;
4. Facilitate safe, pleasant, and convenient pedestrian circulation and minimize
conflict between pedestrians and vehicles;
5. To encourage owner occupancy and retention of single-family and low-density family residential structures compatible with the character of the Midtown
residential neighborhood;
6. To develop an appropriate transition between higher densities in Midtown SPI-16 district to the west of Piedmont Avenue and lower densities in Midtown residential area along and east of Piedmont Avenue, in such a way as to reinforce visual continuities, urban design linkages, appropriate transportation corridors, and neighborhood street patterns;
7. To provide appropriate and distinct entrances into the Midtown neighborhood to the east;
8. To require general compatibility between and among new structures and historic
buildings within the Piedmont Avenue Special Public Interest District;
9. To provide and protect existing single and low-density residential housing along Piedmont Avenue that does not detract
from adjacent single-family housing.
10. Prevent encroachment of incompatible commercial uses and parking into
residential neighborhoods;
11. Protect the historic character of Piedmont Avenue and the adjoining residential
neighborhoods;
12. To protect and enhance traditional buildings and uses within the 10th Street commercial node by retaining historic
structures and uses and encouraging the redevelopment of non-historic properties compatible with historic structures.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.003. Boundaries of district established.
The boundaries of the SPI-17 Piedmont Avenue Special Public Interest District are shown on map attachment B which by this reference is incorporated into and made a part of this chapter and this part. The Piedmont Avenue Special Public Interest District is divided into four subareas as shown on said map attachment B and are described as follows:
Subarea 1: 14th and Piedmont.
Subarea 2: Piedmont North.
Subarea 3: 10th and Piedmont.
Subarea 4: Piedmont South.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.004. Application procedures.
1. A special administrative permit (SAP) application and a specified number of copies each of a site plan, landscape plan, and elevation drawings of each exterior façade shall be submitted, as applicable, and approved by the office of zoning and development prior to filing for a building permit. All exterior demolition, new construction (including additions to existing buildings), new or expanded outdoor dining, or work which results in increased lot coverage, modification of the building footprint, or modification of building facades that would reduce the configuration of street facing openings, shall be subject to said SAP approval. All applications for a SAP shall be processed in accordance with the standards and procedures contained in Chapter 25 of Part 16 except as otherwise modified by this Chapter 18Q. No SAP shall be issued until after such time any other required special use permit or board of zoning adjustment action has been obtained.
2. In addition to SAP submittal as specified above, the applicant shall also provide one copy of the full SAP application to the appropriate neighborhood planning unit (NPU) chair or their designee for the purpose of notification and comment. Said appropriate NPU shall have a period of 21 days from the date of the mailing to provide a set of written comments to the bureau of planning for their consideration prior to any SAP approval.
3. Administrative variations: As part of general action when plans require approval of an SAP, the office of zoning and development may authorize variations from regulations generally applying based on written findings, to be filed as a public record, that either:
a. A plan proposed by an applicant, while not strictly in accordance with regulations applying generally within the district, satisfies the public purposes and intent of such regulations, and provides public protection to an equivalent or
greater degree than strict enforcement of such regulations would provide; or
b. In the circumstances of the case, strict application of a particular regulation or regulations is not necessary for the
accomplishment of public purposes or the provision of public protection, at that time or in the future.
c. Notwithstanding any provision in this chapter or part to the contrary, no
administrative variation shall be authorized for those listed in Section 16-18Q.009 for the board of zoning adjustments.
4. The office of zoning and development may exempt certain classes of applications for SAPs from detailed review requirements as set forth upon written findings that generally within these districts, the actions proposed are of such a character or scale as to make detailed reviews and approval unnecessary. Where applications for special administrative permits are determined by reference to such findings to be thus exempted, the permit shall be issued if otherwise lawful.
5. For the purposes of this chapter, a unified development plan approved under a single SAP and meeting all floor area ratio requirements, open space requirements, and off-street parking requirements, may be subdivided, even if the resultant parcels do not otherwise meet these requirements. Any changes from the approved SAP shall require a new or amended SAP, which Permitted Uses and Structures
P=Permitted Principal Uses & Structures SUP=Special Use Permit X=Not Permitted Subarea 1: 14th & Piedmont Subarea 2:
Piedmont North Subarea 3: 10th & Piedmont Subarea 4:
Piedmont South Defined as a Nightclub or Lounge in Chapter 10 - Alcoholic Beverages
X X X X
Grocery Store (but not a defined Small Discount Variety Store)
P P* (5,000 s.f.
limit) X X Laundry/Tailoring X P* (2,000 s.f.
limit) P* (2,000 s.f.
limit) X Professional/Personal Services including Barber/ Beauty Shops
X P* (2,000 s.f.
limit) P* (8,000 s.f.
limit) X Retail Establishments X P* (5,000 s.f.
limit) P* (5,000 s.f.
limit) X Sales and Repair Establishments (but not auto sales & repair)
X P* (5,000 s.f.
limit) P* (5,000 s.f.
limit) X Institutional / Specialty Childcare Centers SUP SUP SUP SUP Religious Worship Facilities (and their ministries including Farmer's Markets)
SUP SUP SUP SUP
Museums/Galleries/Libraries X X P* (5,000 s.f.
limit) X Public and Private Schools X SUP SUP X Office Medical/Dental Office or Clinic (*Any Veterinary Clinic must be in soundproof building)
X P* (5,000 s.f.
limit) P* (8,000 s.f.
limit) X Offices (other than Medical/Dental Office or Clinic) X P* (5,000 s.f.
limit) P* (8,000 s.f.
limit) X Outdoor / Utility Broadcast Telecommunication Towers X X SUP X Farmers Markets X P P X
Market Gardens P P P P Outdoor amusement enterprises, entertainment, music venues, meetings, or sales areas 90 days duration or less
X SAP SAP X
90 days duration or more
X SUP SUP X
Park-for-hire surface parking lots X X X X Structures/Uses for MARTA P P P P
Urban Gardens P P P P
5. Exclusions: No use or manner of operation shall be permitted which is obnoxious or offensive by reason of odor, smoke, noise, glare, fumes, gas, vibration, unusual danger of fire or explosion, emission of particulate matter, or interference with radio or television communication, or is otherwise incompatible with the character of the district.
6. Use enclosure requirements:
a. Outdoor displays of merchandise are prohibited in sidewalk street furniture zones or clear zones.
b. When located within a supplemental zone, outdoor displays of merchandise are
allowed provided that all items are removed and placed inside a fully enclosed structure at the end of daily business.
7. Transfer of development rights: Transfer of development rights is permissible via special use permit provided meeting the criteria found in Section 16-28.023. Both the sending and receiving properties must be located within either SPI-16 (Midtown Special Public Interest District) or this SPI-17 (Piedmont Avenue Special Public Interest District) whereas for purposes of Section 16-28.023, properties shall be deemed to be closely proximate if both lie within either of these districts.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.006. Permitted accessory uses and structures.
1. Accessory uses and structures permitted within this district shall include those customarily accessory and clearly incidental to permitted principal uses and structures and specifically include clubhouses, pools (and other recreation amenities), pet amenities, bike parking and pair, auto parking to serve authorized uses, outdoor dining, exhibits and displays (without commercial sales transactions) and electric vehicle charging stations equipped with Level 1, Level 2, and/or DC Fast Charge EVSE.
2. Within Subarea 4: Accessory buildings or structures shall meet the following criteria:
a. Location: Shall be placed to the rear of the main structure and, unless adjacent
to an alley, shall meet all setbacks (unless given approval by the City's Board of
Zoning Adjustment);
b. Coverage: The building footprint shall not cover more than 25 percent of the
rear yard;
c. Height: Shall not exceed the lessor of 24 feet in height or the height of the main structure, whichever lesser;
d. Density: Shall not exceed a floor area of 30 percent of the main structure; and
e. Concurrency: Construction and occupancy of a principal building shall occur concurrent or ahead of construction and occupancy for an accessory building.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.007. Redevelopment requirements.
Any property wherein 60 percent or greater of the principal building is removed or destroyed by any means shall be redeveloped in accordance with the requirements of this chapter and any paving or other accessory structural elements within any required transitional yard shall be removed and buffers provided as required herein, notwithstanding any other provisions in Part 16 to the contrary.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.008. Transitional uses and yards.
1. Transitional height planes:
a. No portion of any structure shall protrude through a height limiting plane beginning the specified number of feet above the point set forth in subsection
16-18Q.009(1)(b) below and extending inward over the SPI-17 district at an angle of 45 degrees. The following districts shall be considered "protected districts" for purposes of this subsection
16-18Q.009(1).
i. R-1 through R-5;
ii. RG-1 through RG-3;
iii. MR-1 through MR-3 and MR-MU;
and iv. Landmark, Historic, PD, and SPI districts and district subareas having uses and densities predominantly similar to those permitted in the district classifications listed in subsections (i) through (iii) above.
b. Proximity to districts and measurement applications:
i. For parcels in an SPI-17 district that are contiguous to a protected district, the transitional height plane shall be measured beginning 35 feet above the required SPI-17 setback or transitional yard adjoining the common property line with such protected district.
ii. For parcels in an SPI-17 district that are not contiguous to but are within 150 feet of a protected district, the transitional height plane shall
be measured beginning 15 feet above the nearest lot line of the protected district, provided this transitional height plane shall not extend more Sec. 16-18Q.011. Open space requirements.
1. Required open space: The minimum required open space, as defined in Section 16-18Q.010(2), shall be a percentage of the gross lot area (GLA) and as noted in Table 3: SPI-17 Open Space Table below. In the case of a mixed-use development the required open space shall be the greatest square footage of open space applicable to that component so that any lesser square footage of open space of any other component does not apply.
2. For the purposes of this chapter, open space shall be defined in Section 16-28.010(5.a) except any balconies for residential units above sidewalklevel shall not count toward open space. Any of the following may count as open space:
a. Required yards on private property including planted areas, fountains, plazas, hardscape elements related to walkways, sidewalks and plazas, and similar
features;
b. Required portions of sidewalk widths on private property;
c. Any supplemental zone area(s) which meets Section 16-18Q.013;
d. Any portion of a low-sloped roof (less than or equal to 2:12) designed for vegetation;
e. Any new on-street parking if:
i. On-street parking currently does not exist in the public right-of-way adjacent to the project area for which credit is sought; and ii. The new on-street parking is located where there is no existing street
lane.
Table 3: SPI-17 Open Space Table 14th & Piedmont (SA-1) Piedmont North (SA-2) 10th & Piedmont (SA-3) Piedmont South (SA-4) Residential & Lodging Uses 25% 25% 25% 30% Non-Residential Uses 20% 20% 20% 20%
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27-22) Sec. 16-18Q.012. Sidewalks.
Public sidewalks shall consist of two zones: a street furniture zone and a clear zone. Each zone shall be located along all public streets as noted in Table 4: SPI-17 Sidewalk Table and is subject to the following:
1. Street furniture zone requirements: Said zone shall be continuous and located
adjacent to granite curbing and shall meet tree planting requirements of Section 16-18Q.012(2) below. The area between tree planting areas shall either be planted with evergreen ground cover
such as mondo grass or a liriope species or shall be constructed in accordance
with the Midtown Streetscape Plan. In addition, this zone may be used for street furniture specified by the office of zoning and development in coordination with
the city's department of transportation and accordance with the Midtown Streetscape Plan. This furniture may include trash receptacles, traffic signs, bus
shelters, bicycle racks, benches, tree fencing, and utility poles (where allowed) or similar elements in accordance with
uniform design standards utilized for the placement of such objects in the public
right-of-way in a manner that does not obstruct pedestrian access or motorist visibility.
2. Street tree requirements: Street trees are required to be installed within the street furniture zone spaced equidistant between streetlights as specified in the Table 4:
SPI-17 Sidewalk Table below and in accordance with the Midtown Streetscape Plan. All newly planted trees shall be single stemmed with a minimum of
three inches in caliper measured 36 inches above ground, at least 12 feet in height and limbed up to a minimum height of
seven feet. Trees shall and have a minimum planting area of 40 square feet planted with evergreen ground cover such as mondo grass or a liriope species. All plantings, including replacement and
removal, shall be approved by the city arborist. Tree grates are prohibited.
3. Streetlight requirements: Street lights that meet a standard Atlanta type as approved by the Office of Zoning and Development
are required to be installed within the street furniture zone spaced equidistant between required street trees as specified in the Table 4: SPI-17 Sidewalk Table. See also lighting requirements in Secction 16-18Q.010(4).
4. Clear zone requirements: Said zone shall be continuous standard concrete hardscape located contiguous to the street furniture zone at widths specified in the Table 4: SPI-17 Sidewalk Table above.
The clear zone shall be unobstructed by any permanent or non-permanent element to a minimum height of ten feet.
No awning or canopy shall encroach into the clear zone. Where property within this district abuts another district without an intervening street, the sidewalk shall taper as necessary to provide a smooth
transition to the abutting district sidewalk. If the abutting district has no existing sidewalk, the sidewalk shall taper to a width of six feet.
5. Visibility triangles: Nothing shall be erected, placed, planted or allowed to
grow in such a manner as to impede visibility within visibility triangles at street intersections between the heights of 2 feet and eight feet above grade.
See also Section 16-28.009: Visibility at Intersections.
6. Overhead utilities: Every reasonable effort shall be made to place utilities
underground or to the rear of structures to allow for unobstructed use of sidewalks.
7. Outdoor dining within the street furniture and clear zones: Buildings existing prior to 2001 with sidewalks not meeting the
requirements of this chapter may have outdoor dining encroaching into such zones provided the following criteria are met:
a. All streets shall have a minimum six (6) feet of unobstructed sidewalk area adjacent to the curb; and
b. No permanent structure or ornamentation shall be located within the encroachment area and no element shall be attached to the sidewalk in any way; and
c. At such time as the outdoor dining use is discontinued, sidewalks shall comply with all requirements of this chapter.
Table 4: SPI-17 Sidewalk Table Subarea 1: 14th & Piedmont Subarea 2: Piedmont North Subarea 3: 10th & Piedmont Subarea 4: Piedmont South Min. Street Furniture Zone Width 5' 5' 5' 3' (match existing pavement material/pattern) Street Tree Planting -
Maximum Spacing 40' on-center 40' on-center 40' on-center 40' on-center Street Lighting -
Maximum Spacing 40' on-center 40' on-center 40' on-center 40' on-center Min. Clear Zone Width 10' 10' 10' 6' (match existing pavement material/pattern) Min. Supplemental
Zone Width 15' with min. 5' of landscaping adjacent to the clear zone1 15' with min. 5' of landscaping adjacent to the clear zone1 5' 30' Min. Street Facing Setback 30' 30' 20' 39' 1 Pedestrian walkways to entries are allowed perpendicular to the street within the min. 5' required landscaping.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27-22) Sec. 16-18Q.013. Supplemental zone.
For purposes of these regulations, the supplemental zone is defined as the area between a clear sidewalk zone and any building façade line or parking lot when no intervening building exists. Supplemental zones shall meet the widths as specified in the Table 4: SPI-17 Sidewalk Table above and the following requirements:
1. When sidewalk level residential units are provided the supplemental zone shall be landscaped except for terraces, porches, stoops, stairs and walkways. Such
landscaped areas shall occupy a minimum of two-thirds of the supplemental zone area.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.