2. The supplemental zone shall be no more than 30 inches above finished grade unless existing topography requires a greater
height.
3. Terraces, porches and stoops shall have a maximum finished floor height of 36
inches above finished grade, unless existing topography requires a greater height.
4. Walls, as defined in Section 16-29.001(25), shall not be allowed between the street
and any uilding except for retaining walls which shall be no more than 36 inches in height unless existing topography requires retaining walls of a greater height. Any retaining walls shall be finished poured concrete or shall be faced with stone,
brick, or smooth stucco.
5. Fencing and similar barriers, as defined in Section 16-29.001(25), shall only be
permitted up to 42 inches in height (including any plant material) in a supplemental zone and only for sidewalk level residential uses or to separate authorized outdoor dining. Such outdoor dining may only be separated by nonfixed fencing (or similar barriers or movable planters). Other fencing is otherwise prohibited when located between the
street and any building.
6. The area contained within the defined supplemental zone, except for any
automobile driveways and/or parking, may be counted toward the open space requirements found in Section 16-18Q.011.
7. Within Subarea 1: The supplemental zone shall include one or more shade trees as approved by the City Arborist at a ratio of the greater of either: a) one tree; or b) one tree for each 500 square feet of
supplemental zone area. Such tree(s) shall have a min. mature height of 50 feet.
8. Within Subarea 4: The supplemental zone shall meet the following criteria:
a. Coverage: No more that 25 percent of the supplemental zone area shall be utilized for automobile parking and/or a driveway.
b. Trees: A minimum of one shade tree as approved by the City Arborist shall be provided. Such tree(s) shall have a min. mature height of 50 feet.
c. Vegetation: Shrubs, hedges (and similar) if installed within ten feet of a sidewalk, shall have a maximum maintained height of 42 inches.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.014. Relationship of building to street.
1. For purposes of this chapter, sidewalk level shall be defined as any floor of a building with a finished-floor elevation less than or equal to five feet above and below the adjacent sidewalk (or street if no sidewalk is existing).
2. Building floors shall be delineated from the third story above sidewalk level down to each sidewalk level and shall be executed through windows, belt courses, cornice lines and/or similar architectural detailing.
3. General sidewalk level building façade requirements:
a. Active uses along all streets shall be provided as indicated in Table 1: SPI-17 Table of Uses in Section 16-18Q.005, to a minimum depth of 40 feet for nonresidential uses and 20 feet for residential uses beginning at any sidewalk level
street facing building façade except when topographical conditions prevent such
treatment. These active uses shall be internally illuminated and serviced by plumbing, heating, and electricity and are limited to uses set forth in Table 1:
SPI-17 Table of Uses, with the following exceptions which also shall be allowed:
i. Fire command and transformer (or similar electrical) rooms, each not exceeding 10 feet of street fronting façade length; and ii. Structures required for public transit.
b. The primary street fronting pedestrian entrance for sidewalk level uses:
i. Shall face, be visible and accessible from the clear zone sidewalk with a
minimum of five feet wide pedestrian walkway; and ii. Shall have a minimum six inch high street address located directly near the primary building entrance clearly visible from the sidewalk.
iii. Shall have a visible and accessible push button activator seen from the
clear zone sidewalk connected with a minimum five foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit. This provision shall not apply to single-family and two-family residential
structures.
c. Residential uses which do not have street frontage shall be linked to the public
sidewalk with a minimum four feet wide pedestrian walkway.
4. Fenestration requirements: Street-fronting sidewalk level building façades, except churches/ religious institutions, fire stations & MARTA uses, shall meet the following requirements:
a. Length: Fenestration and entrances shall be provided for a minimum of the
horizontal length of each street-fronting sidewalk-level façade, as designated in
the Table 5: SPI-17 Street Activation Table. The length of façade without intervening fenestration or entryways shall not exceed 20 feet.
b. Surface treatment and visibility: Windows and door glass shall utilize clear glass or tinted glass. Tinted glass shall have a
transmittance factor of 50 percent or greater and shall have a visible light reflectance factor of ten or less having visibility into the building for a minimum depth of ten feet as measured from the
interior windowpane. Painted glass, reflective glass or other similarly treated or opaque windows are prohibited.
c. Residential uses: Fenestration and entrances shall have windows at a minimum of four feet in height.
d. Non-residential uses: Fenestration and entrances shall be measured beginning
at a point not more than 36 inches above the required sidewalk to a height at least ten feet above the sidewalk unless:
i. When the finished floor elevation is 36 or more inches above the sidewalk:
Beginning at finished floor elevation to at least ten feet above the finished floor elevation; or
ii. When the finished floor elevation is below the sidewalk: Beginning at a
point not higher than six inches above the adjacent sidewalk to at least ten feet above the finished floor elevation.
Table 5: SPI-17 Street Activation Table Use (as further regulated in Table 1: SPI-17 Table of Uses) Min. Fenestration (as % of street level façade) Outdoor Facilities including:
Farmer's Markets, Market Gardens, Urban Gardens Outdoor amusement enterprises, entertainment, music venues, meetings or sales areas.
None - Not Applicable Residential dwellings Bed & Breakfast Inn Childcare Centers Churches/Religious Facilities Clubs/Lodges Hotel & Motel Lodging Nursing Homes/ Personal Care Homes / Assisted Living Facilities/ Rehabilitation Centers Supportive Housing Veterinary 30% All other uses (allowed in Table 1 in Section 16-18Q.005 but not listed above):
65% (Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22; Ord. No. 2026-05(26-O-1001), § 9, 2-25-26) Sec. 16-18Q.015. Signage.
Refer to Section 16-28A. Sign Ordinance and Section 16-18Q.017(9) below.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.016. Off-street loading requirements, dumpsters and building mechanical and accessory features.
1. The off-street loading requirements for this district are as shown in the table in Section 16-28.015, Off-Street Loading Requirements. See the specific screening requirements below.
2. Loading area and dock screening:
a. Loading areas shall be screened so as not to be visible from any public plaza, outdoor dining area, public sidewalk or public
right-of-way with the exception of hotel uses. Hotel uses may utilize on-street
loading if orientated predominately parallel to the adjacent right-of-way and located fully outside any existing public driving lane and at least partially on private
property at a maximum length of 60 feet as permitted by the Department of Public Works.
b. Loading dock entrances shall be screened so that loading docks and related activity are not visible from the public right-ofway when not in use.
3. Dumpsters and trash areas: Dumpsters and trash areas shall be screened so as not to be visible from any public plaza, outdoor dining area, public sidewalk or public right-of-way and if otherwise visible shall be enclosed with opaque walls six feet in height.
4. Building mechanical and accessory features:
Shall be in the location of least visibility from the public right-of-way. If located to the side or rear of the principal structure, screening with plant or fence materials shall be required. When located on rooftops, said features shall be incorporated in the design of the building and/or screened with building materials similar to those of the building.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.017. Curb cuts and parking structures.
1. Sidewalks at curbcuts and driveways: All sidewalk paving materials shall be continued across any intervening driveway. On each side of the continuous sidewalk a band of textured concrete shall be provided located both in-line with and equal in width to the street furniture zone and in-line with the supplemental zone or building façade at a minimum five feet width.
2. Curbcut restrictions:
a. If fronting Piedmont Avenue: No vehicular entrances to properties fronting along
Piedmont Avenue are allowed when access may be provided from a side or rear street, except for either: a) hotel or b) bed and breakfast uses.
b. If not fronting Piedmont Avenue: No more than one curb cut shall be permitted for each development, provided that properties with more than one street frontage may have two curb cuts.
3. Curbcut widths: Curb cuts shall be limited in width at the sidewalk to 12 feet for one-way entrances and 24 feet for two-way entrances unless a greater width is approved by the Department of Public Works upon its finding of necessity of such a greater width.
4. Driveway and vehicular services configuration:
a. Driveways shall be predominately perpendicular to any adjacent street, except for hotel uses which may have circular drives for the purpose of drop-off and pick-up. Driveways predominately
parallel to the street are otherwise prohibited.
b. Entrances to garages and carports that serve one or more contiguous sidewalklevel residential units only shall share one common drive with any garages and
carports facing rear or side yards having no street frontage.
c. Drive-through and drive-in facilities (including any fuel service) shall be
prohibited.
5. Shared access: Notwithstanding the provisions of Section 16-28.006(10), a common or joint driveway may be authorized when adjacent lots have direct vehicular access to a publicly accessible street and a perpetual easement agreement is agreed upon by all affected property owners and included in the SAP application.
6. Drop-off lanes: No drop-off lanes shall be permitted along public streets except for hotel uses as approved by the department of public works.
7. Parking structure public screening: In addition to Section 16-28.028, parking structures shall have the following additional requirements:
a. At a height of 20 feet or less above finished grade which faces any public or private street shall meet Section
16-18Q.014(3)(a) to provide an intervening building having conditioned habitable space along the length of such parking structure.
b. At a height of 20 feet or more above finished grade which faces any public or private street shall provide either:
i. An intervening building at average depth of 20 feet having conditioned habitable space along the length of such parking structure; or ii. All openings of the parking structure shall be fully screened from view
from adjacent public or private streets so that cars, sloped ramps, and interior deck lighting are not visible from adjacent streets. In addition, the façade design of said parking structure shall be compatible with the principal building in terms
of architectural style, texture, quality and material; and
c. Side or rear yard facing parking deck façades that are exposed and visible from a public street, shall screen such visible portions of the parking deck utilizing the parking deck screening regulations
provided in Section 16-28.028(1)(b)(ii).
8. Parking structure buffers: Along all nonstreet facing sides of parking structures a minimum ten feet wide continuous landscaped strip shall be provided between the structure and the property line(s). This landscaped strip shall be planted with a combination of trees and evergreen ground cover such as mondo grass, liriope species, ivy or shrubs with all plantings to be approved by the city arborist.
9. Public parking signage: Parking facilities providing public parking spaces shall provide standard signage indicating public parking in accordance with the Midtown standard in
coordination with the City of Atlanta.
10. Pedestrian walkways from parking: All sidewalk level parking, including parking decks, shall have walkways a minimum width of four feet connecting such parking to the public sidewalks and to building entrances.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.018. Bicycle parking requirements.
See Section 16-28.014(6), Bicycle parking requirements.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
Sec. 16-18Q.019. Vehicular off-street parking requirements.
In addition to the provisions of Section 16-28.008(7), Sections 16-28.013 and 16-28.014, the vehicular parking requirements set forth in Table 6: SPI-17 Off Street Parking Requirements shall apply and are further subject to subsections 1 through 2 below:
Table 6: SPI-17 Off-Street Parking Requirements Use Minimum Spaces Maximum Spaces1
Residential / Housing Residential - single-family and two-family Personal Care Home
Supportive Housing No minimum 1.0 per bedroom Residential - multi-family No minimum 1.o per bedroom and 2.o per 2+ bedrooms
Nursing homes, convalescent homes and similar care facilities
1.0 per each 4 bedrooms 1.0 per each 2 bedrooms Lodging
Bed and Breakfast Inn 0.5 per rental room, plus 1 per manager
1 per rental room, plus 1 per manager Hotel & Motel Lodging (not including eating and drinking establishment)
0.5 per rental room, plus 1/300 s.f.
convention (assembly) facilities 1 per rental room, plus 1/200 s.f.
convention (assembly) facilities Commercial Professional/Personal Services (including Barber/ Beauty Shops)
Grocery Stores Small Discount Variety Stores 1/ 100 s.f. 15 / 1,000 s.f.
Commercial Recreation 1/ 100 s.f. 30/ 1000 s.f.
Eating & Drinking Establishments Indoor Dining 1/ 100 s.f. 15 / 1,000 s.f.
Eating & Drinking Establishments - Outdoor Dining
1/ 200 s.f 20 / 1,000 s.f.
Retail Establishments 1 /200 s.f. 7.5 / 1,000 s.f.
Other Commercial Uses - not listed in the Commercial category above 1 /200 s.f. 7.5 / 1,000 s.f.
Institutional /Specialty Child Care Centers (shall also provide safe and convenient facilities for loading and unloading children, as approved by the Atlanta Department of Transportation)
One space for each onsite staff member plus 1 space for each classroom One space for each onsite staff member plus 2.0 spaces for each classroom Churches/Religious Facilities The greater of:
One space for each six fixed seats with 18 inches if bench length counted as one seat; or one space for each 50 square feet of enclosed floor area for the accommodation of movable seats in the largest assembly room.
50% more than the minimum spaces prescribed at left.
Clubs/Lodges 1/ 100 s.f. No maximum Museums/Galleries/Libraries 1/ 100 s.f. No maximum Other Institutional / Specialty uses allowed See below 'Uses Requiring a Special Permit (not listed above)'
No maximum Office Medical/Dental Office or Clinic 1/ 200 s.f. 9 / 1,000 s.f. (may be shared with other uses)
Offices 1/ 250 s.f. 4.0 / 1,000 s.f. (may be shared with other uses)
Outdoor/ Utility Outdoor / Utility uses allowed No minimum No maximum Uses Requiring a Special Use Permit (not listed above) All other uses allowed by Special Use Permit, which are not specified in this Table shall provide off-street parking based on the parameters and applicable conditions of the required special use permit.
Use Minimum Spaces Maximum Spaces1 Electric/Alternative Fuel Vehicle Charging Stations All parking facilities shall provide electrical vehicle charging stations
1 station for every 50 automobile parking spaces No maximum 1Parking spaces provided in excess of the parking requirements above shall only be allowed as park-for-hire spaces located within a parking structure.
1. Off-street surface parking:
a. Shall not be located closer to a street than any on-site building façade and shall not occupy more than 50 percent of any street frontage parcel length.
b. Shall be accessory to a permitted principal use only, provided that parking spaces serving another principal permitted use may use such facility for shared parking as specified above.
c. Park-for-hire surface parking lot(s) as a principal use are prohibited.
2. Parking, lighting, security, landscaping, and maintenance. All surface parking
lots and structures, whether a principle or accessory use, shall meet the following requirements:
a. Lighting shall be provided throughout all parking facilities to equal a minimum of one-half footcandle of light but shall reduce light spillage onto adjacent properties by
providing cutoff luminaries with a maximum 90-degree illumination.
For parking structures ingress and egress points such lighting shall be a minimum of one footcandle of light. Where applicable, public and other ambient lighting may be utilized to fulfill these lighting requirements; however, if removed it shall be required to independently provide these required levels of illumination.
b. Surface parking lots: The requirements of City of Atlanta Chapter 158 Vegetation, Article II Tree
Protection, Section 30 Parking lot requirements shall apply to this district regardless of the size of the lot.
c. Parking facilities shall be maintained in a clean, safe, and sanitary condition with parking spaces and driving lanes clearly defined and maintained. See also Section
16-28.014 for additional requirements.
(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27- 22)
CHAPTER 16-18R. SPI-18
MECHANICSVILLE NEIGHBORHOOD
SPECIAL PUBLIC INTEREST DISTRICT
REGULATIONS*
The regulations set forth in this chapter, or set forth elsewhere in this part when referred to in this chapter, are the regulations for the SPI-18 Mechanicsville Neighborhood Special Public Interest District. These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in section 16-18R.003, except that all existing categories of historic protection designated pursuant to Chapter 20 of Part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this chapter. Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. Whenever the fol-lowing regulations conflict with provisions of Part 16 other than historic protection regulations, the more stringent regulation shall apply.
The regulations set forth in sections 16-18R.001 through and including section 16-18R.025 shall apply to all properties located within the SPI-18 Mechanicsville Neighborhood Special Public Interest District, including all subareas within the district, unless otherwise indicated by subarea.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.002. Statement of intent.
The intent of the council in establishing SPI-18 Mechanicsville Neighborhood Special Public Interest District as a zoning district is as follows:
1. Create a diversified city where people across the spectrum of age, income, ethnicity, and culture can live, work, shop, meet, and play;
2. Improve the aesthetics of streets and the built environment;
3. Ensure through the administration of specific standards and criteria that new housing achieve architectural, site and
street design consistent with the existing historic built environment.
4. Protect the historic character of the singlefamily residential areas;
5. Facilitate safe, pleasant, and convenient sidewalk-level pedestrian circulation that minimizes impediments by vehicles;
6. Promote public safety through the provision of pedestrian-oriented street-level uses, sufficient sidewalk widths, adequate visibility from adjacent buildings and
primary pedestrian access from buildings to adjacent sidewalks;
7. Ensure pedestrian-oriented building forms which are compatible with the scale,
character and needs of the neighborhood;
8. Encourage a grid of connected streets to improve access and reduce congestion:
9. Facilitate safe and convenient bicycle usage;
10. Encourage a compatible mixture of residential, commercial, cultural and recreational uses;
11. Promote an appropriate balance and scale of commercial uses which meet the needs
of nearby residents;
12. Encourage infill and rehabilitation development within traditionally commercial areas that include proportionately significant residential uses;
13. Place reasonable controls on the development of larger scale highway-oriented retail, service, office and dining uses
which are intended to serve larger areas of the city than a single neighborhood or a small group of neighborhoods;
14. Encourage owner occupancy and retention of single-family residential structures compatible with the character of the
c. Minimum landscape requirements. There shall be a minimum number of trees
within the sidewalk and within the setback areas that shall equal one tree per 25 linear feet of property line. Such trees shall have a minimum mature height of 60 feet, as approved by the city arborist.
5. Sidewalks.
a. Street furniture and tree planting zone.
The street furniture and tree planting zone shall have a minimum width of five feet.
b. Clear zone. The clear zone shall be a minimum width of ten feet.
6. Supplemental zones. For purposes of these regulations, the area between any building, parking deck, or surface parking lot and the required sidewalk, when no intervening building exists, shall be defined as the supplemental zone.
Supplemental zones shall meet the following requirements. Except as otherwise specified below, the square footage contained within a
supplemental zone which meets all the following supplemental zone requirements may be counted towards UOSR or public space requirements.
Supplemental zones shall meet the following additional requirements:
a. Minimum width: 15 feet, including landscaping a minimum width of five feet adjacent to the sidewalk and traversed only by steps or walkways;
b. Terraces, porches and stoops shall have a maximum finished floor height of 24
inches above finished-grade, unless existing topographical considerations render this requirement unreasonable;
c. When sidewalk level residential units are provided, supplemental zone shall be landscaped with the exception of terraces, porches, stoops and walkways, which may occupy a maximum of twothirds of the front yard or supplemental zone area;
d. The supplemental zone shall be no more than 24 inches above the adjacent public sidewalk for a minimum distance of 15
feet from the nearest edge of the adjacent public sidewalk, unless existing
topographical considerations render this requirement unreasonable;
e. Any authorized walls surrounding landscaped and grassed areas shall not exceed a maximum height of 24 inches, except retaining walls, which shall not exceed a maximum height of 36 inches unless existing topography requires a retaining wall of greater height; and
f. Fencing shall be permitted only when:
i. The supplemental zone is located between sidewalk level residential units and the adjacent street; or ii. Said fencing is used to separate authorized outdoor dining from the required sidewalk.
7. Curb cuts and parking structures. All sidewalk paving materials shall be continued across any intervening driveway.
(Ord. No. 2001-85, § 1, 11-14-01; Ord. No.
2014-22(14-O-1092), § 2-DD-iii, 6-11-14; Ord.
No. 2019-66(19-O-1504), § 15, 12-11-19; Ord. No.
2020-58(19-O-1393), § 40, 10-28-20) Sec. 16-18Q.027. Specific regulations for Subarea 3: 10th and
Piedmont.
1. Permitted uses. In addition to those uses authorized in section 16-18Q.005, a building or premises may be used for the following permitted uses and structures:
a. The following commercial uses are authorized provided they do not exceed 2,000 square feet of floor area and subject to the restrictions below:
i. Bakeries and catering establishments.
ii. Eating and drinking establishments, including those licensed for the onpremises consumption of malt beverages, wine and/or distilled spirits.
iii. Laundry and dry cleaning collection stations, laundry and dry cleaning
establishments where customers operate equipment.
iv. Tailoring, custom dressmaking, and millinery.
b. The following commercial uses are authorized provided they do not exceed 5,000 square feet of floor area and subject to the restrictions below:
i. Clubs and lodges.
ii. Museums, galleries, auditoriums, libraries and similar cultural facilities.
iii. Repair establishments for home appliances, bicycles, shoes, clocks and similar household goods, with the exception of motorized vehicles.
iv. Retail establishments and grocery stores.
c. The following commercial uses are authorized provided they do not exceed 8,000 square feet of floor area and subject to the restrictions below:
i. Banks, savings and loan associations, and similar financial institutions but not including any drive-in service window, except walk-up
automatic teller machines and night drop.
ii. Barber shops, beauty shops, manicure shops and similar personal service establishments.
iii. Commercial recreational establishments, including bowling alleys, theaters, convention halls, places of
assembly and similar uses with primary activities conducted within fully enclosed buildings.
iv. Offices, studios, clinics (including veterinary), laboratories and similar
uses, but not blood donor stations except at hospitals. Veterinary clinics including all kennels and accessory areas shall be enclosed within soundproof buildings.
v. Professional or personal service establishments.
d. All commercial sales and service shall be conducted within enclosed permanent
structures and there shall be no unenclosed displays of merchandise with the exception of market gardens, offstreet parking and outdoor dining.
Unenclosed outdoor sales or displays are permissible only by special permit as set forth below.
e. Market gardens.
2. Special permits. The following uses are permissible only by special permits subject to limitations and requirements set forth herein or elsewhere in this part, subject to the procedures and requirements set forth in sections 16-18Q.005 and 16-25.004:
a. Special use permits.
i. Accessory outdoor dining in use after 11 p.m. for eating and drinking
establishments.
ii. Broadcasting towers and line-ofsight relay devices for telephonic, radio or television communications
greater than 70 feet in height, except alternative design mounting structures as contemplated by section 16-25.002(3)(h)(iv)(i).
iii. Eating and drinking establishments greater than 2,000 square feet of floor area, including those licensed for the on-premises consumption of malt beverages, wine and/or distilled spirits.
iv. Hotels containing no more than 30 rooms. Further, said hotels shall contain no more than 500 square feet of meeting facilities and no hotels shall be located within 500 feet of any public school or secondary school boundary.
v. Nursing homes and convalescent centers.
vi. Outdoor displays of merchandise on or adjacent to the sidewalk provided all other sidewalk requirements are met.
b. Special administrative permit. Outdoor amusement enterprises, exhibits,
entertainment, meetings, display or sales areas, or outdoor areas for religious
ceremonies of less than 30 days duration.
c. Special administrative permit. Party houses provided that the use shall be prohibited within 150 feet of a property zoned R-1, R-2, R-2A, R-2B, R-3, R-3A,
R-4, R-4A, R-4B, R-5, RG, MR or a property used for residential purposes measured from property line to property line.
3. Development controls.
a. Rear and side yards. Side and rear yards shall be permitted to have private alleys or drives a maximum of ten feet in width.
i. Rear yards: 20 feet.
ii. Side yards.
a). Nonresidential uses: None.
b). Residential uses: Ten feet, except that the side yard may be reduced to zero feet when a residential use has no residential windows adjacent to such yard.
b. Bulk limitations.
i. For nonresidential uses, floor area shall not exceed an amount equal to one and one-half times net lot area.
ii. For residential uses, floor area shall not exceed an amount equal to one
and forty-nine one hundredths times net lot area.
iii. For mixed-use development, floor area shall not exceed the sum of the nonresidential (i) and residential (ii) above, but in no event greater than the maximum ratios permitted for each.
iv. Open space bonus. Residential uses shall be permitted to calculate any of the above floor area ratios in section 16-18Q.027(3) utilizing gross lot area, for purposes of providing additional density based on such calculation. Developments utilizing the open space bonus shall not be permitted any reduction in open space requirements.
c. Showering facilities. All office buildings containing over 50,000 square feet of
gross office space shall provide showering facilities, which shall include showers and lockers, in a ratio of at least two showering facilities for every 50,000
square feet of gross office space, which facilities shall be available to all building tenants and their employees, provided
that no office building shall be required to exceed a maximum of four showering
facilities.
4. Site limitations.
a. Minimum building façade heights: 18 feet along each façade visible from any public right-of-way.
b. Maximum building heights: 35 feet.
c. Maximum building coverage: 85 percent.
5. Sidewalks.
a. The street furniture and tree planting zone shall have a minimum width of five
feet.
b. Clear zone.
i. The clear zone shall be a minimum width of ten feet.
ii. When outdoor dining is provided:
Up to two feet of the clear zone nearest the building may be used for outdoor dining. No permanent element may be placed within the clear zone area.
6. Supplemental zone. For purposes of these regulations, the area between any building, parking deck, or surface parking lot and the required sidewalk, when no intervening building exists, shall be defined as the supplemental zone. Except as otherwise specified below, the square footage contained within a supplemental zone which meets all the following supplemental zone requirements may be counted towards UOSR or public space requirements.
a. Minimum supplemental zone widths: Five feet.
b. Supplemental zones containing a depth of 15 feet or less shall meet the following additional requirements:
i. No balcony shall encroach more than five feet into the supplemental zone area.
ii. Shall not be counted towards UOSR or public space requirements unless visible and accessible to the general public from the adjacent public sidewalk, with the exception of areas adjacent to sidewalk level residential units.
c. Supplemental zones containing a depth greater than 15 feet shall be counted
towards UOSR or public space requirements only when the following additional requirements are met:
i. Shall permit and encourage pedestrians to walk on a minimum of 80 percent of the surface of the parcel excluding fountains, pedestrian furniture, public art and similar elements.
ii. When adjacent nonresidential ground floor uses are provided, shall be visible and accessible from any point along 90 percent of any adjacent sidewalk.
iii. When adjacent nonresidential ground floor uses are provided, all sides of buildings fronting said zone meet the requirements of section 16-18Q.013(9).
iv. When adjacent residential ground floor uses are provided, shall be visible from any point along 90 percent of the adjacent sidewalk.
v. When adjacent residential ground floor uses are provided, shall provide a pedestrian walkway from said space to the adjacent public sidewalk.
Said pedestrian walkway shall be perpendicular to the street and shall connect directly to the public sidewalk and shall be open to the sky along its entire length.
d. Terraces, porches and stoops shall have a maximum finished floor height of 24
inches above finished-grade, unless existing topographical considerations render this requirement unreasonable.
e. When sidewalk level residential units are provided, supplemental zone shall be landscaped with the exception of terraces, porches, stoops and walkways, which may occupy a maximum of twothirds of the front yard or supplemental zone area;
f. The supplemental zone shall be no more than 24 inches above the adjacent public sidewalk for a minimum distance of 15
feet from the nearest edge of the adjacent public sidewalk, unless existing
topographical considerations render this requirement unreasonable;
g. Any authorized walls surrounding landscaped and grassed areas shall not exceed a maximum height of 24 inches, except retaining walls, which shall not exceed a maximum height of 36 inches unless existing topography requires a retaining wall of greater height; and
h. Fencing shall be permitted only when:
i. The supplemental zone is located between sidewalk level residential units and the adjacent street; or ii. Said fencing is used to separate authorized outdoor dining from the required sidewalk.
7. Curb cuts and parking structures. All sidewalk paving materials shall be continued across any intervening driveway.
(Ord. No. 2001-85, § 1, 11-14-01; Ord. No.
2005-41(06-O-0381), §§ 40, 41, 7-12-05; Ord. No.
2014-22(14-O-1092), § 2-DD-iv, 6-11-14; Ord. No.
2020-58(19-O-1393), § 41, 10-28-20) Sec. 16-18Q.028. Specific regulations for Subarea 4: Piedmont
South.
1. Permitted uses.
a. In addition to those uses authorized in section 16-18Q.005, a building or premises may be used for the following permitted
uses and structures:
i. Bed and breakfast inn.
b. The following regulations shall apply to all permitted accessory uses and
structures:
i. No accessory building shall be constructed until construction of the principal building has actually begun, and no accessory building shall be used or occupied until the principal building is completed and is in use.
ii. Accessory buildings shall not cover more than 25 percent of the rear yard.
iii. Accessory structures shall be placed to the rear of the main structure
within the buildable area of the lot, with the exception of structures located in the rear yard setback which do not exceed a maximum width of 24 feet.
iv. Accessory buildings shall not exceed 24 feet in height or the height of the
main structure, whichever is less, shall not contain a total floor area greater than 30 percent of the main structure, and shall not exceed a maximum height of two stories.
2. Development controls.
a. Front yards.
i. 40 feet minimum.
ii. Shall have a maximum of 25 percent paved area, such area to be used for pedestrian access and drives to the rear or side of the building.
iii. Shall have a minimum of one shade tree as approved by the city arborist.
iv. Shrubs and hedges within ten feet of the public sidewalk shall have a maximum mature height of 36 inches.
v. When sidewalk level residential units are provided, shall be landscaped
with the exception of terraces, porches, stoops and walkways, which may occupy a maximum of twothirds of the front yard or supplemental zone area.
vi. Shall be no more than 24 inches above the adjacent public sidewalk for a minimum distance of 15 feet from the nearest edge of the adjacent public sidewalk, unless existing topographical considerations render
this requirement unreasonable.
vii. Any authorized walls surrounding landscaped and grassed areas shall not exceed a maximum height of 24 inches, except retaining walls, which shall not exceed a maximum height of 36 inches unless existing topography requires a retaining wall of greater height.
viii. Fencing shall be permitted only when the front yard is located between
sidewalk level residential units and the adjacent street.
b. Rear and side yards. Side and rear yards shall be permitted to have private alleys or drives a maximum of ten feet in width.
i. Rear yards: Minimum of 20 feet.
Rear yards shall be permitted to have private alleys or drives up to ten feet in width.
ii. Side yards: Minimum of ten feet.
3. Bulk limitations.
a. For nonresidential uses: None.
b. For residential uses, floor area shall not exceed an amount equal to six hundred
ninety-six one thousandths times net lot area.
c. Open space bonus Residential uses shall be permitted to calculate any of the above floor area ratios in section 16-18Q.028(2) utilizing gross lot area, for purposes of providing additional density based on such calculation. Developments utilizing the
open space bonus shall not be permitted any reduction in open space requirements.
4. Maximum building coverage: 50 percent.
5. Minimum pervious surface: 35 percent.
6. Site limitations.
a. Minimum building façade heights: 24 feet.
b. Maximum building heights: 35 feet.
7. Sidewalks. Sidewalks shall be a minimum width of nine feet and shall be paved using either standard concrete or brick.
a. Standard concrete paving.
i. Street furniture and tree planting zone The street furniture and tree planting zone shall have a minimum width of three feet and shall be planted with evergreen groundcover such as mondo grass or Liriope spicata. When provided, street trees shall have a maximum mature diameter of no greater than five inches.
ii. Clear zone. The clear zone shall be a minimum width of six feet.
b. Brick paving.
i. Street furniture and tree planting zone: None required.
ii. Clear zone: The clear zone shall be a minimum width of nine feet.
(Ord. No. 2001-85, § 1, 11-14-01; Ord. No. 2009- 76(09-O-1402), § 5, 12-15-09)
Sec. 16-18R.001. Scope of provisions.
The regulations set forth in this chapter, or set forth elsewhere in this part when referred to in this chapter, are the regulations for the SPI-18 Mechanicsville Neighborhood Special Public Interest District. These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in section 16-18R.003, except that all existing categories of historic protection designated pursuant to Chapter 20 of Part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this chapter. Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. Whenever the following regulations conflict with provisions of Part 16 other than historic protection regulations, the more stringent regulation shall apply.
The regulations set forth in sections 16-18R.001 through and including section 16-18R.025 shall apply to all properties located within the SPI-18 Mechanicsville Neighborhood Special Public Interest District, including all subareas within the district, unless otherwise indicated by subarea.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.002. Statement of intent.
The intent of the council in establishing SPI-18 Mechanicsville Neighborhood Special Public Interest District as a zoning district is as follows:
1. Create a diversified city where people across the spectrum of age, income, ethnicity, and culture can live, work, shop, meet, and play;
2. Improve the aesthetics of streets and the built environment;
3. Ensure through the administration of specific standards and criteria that new housing achieve architectural, site and street design consistent with the existing historic built environment.
4. Protect the historic character of the singlefamily residential areas;
5. Facilitate safe, pleasant, and convenient sidewalk-level pedestrian circulation that minimizes impediments by vehicles;
6. Promote public safety through the provision of pedestrian-oriented street-level uses, sufficient sidewalk widths, adequate visibility from adjacent buildings and primary pedestrian access from buildings to adjacent sidewalks;
7. Ensure pedestrian-oriented building forms which are compatible with the scale, character and needs of the neighborhood;
8. Encourage a grid of connected streets to improve access and reduce congestion:
9. Facilitate safe and convenient bicycle usage;
10. Encourage a compatible mixture of residential, commercial, cultural and recreational uses;
11. Promote an appropriate balance and scale of commercial uses which meet the needs
of nearby residents;
12. Encourage infill and rehabilitation development within traditionally commercial areas that include proportionately significant residential uses;
13. Place reasonable controls on the development of larger scale highway-oriented retail, service, office and dining uses which are intended to serve larger areas of the city than a single neighborhood or a small group of neighborhoods;
14. Encourage owner occupancy and retention of single-family residential structures compatible with the character of the Mechanicsville residential neighborhood
while permitting two-family and multifamily housing in appropriate locations;
15. Provide a range of housing types and prices to meet different housing needs;
16. Prevent encroachment of incompatible commercial uses and minimize commercial parking in residential subareas;
17. Provide accessible and sufficient parking in an unobtrusive manner;
18. Reduce parking requirements by encouraging shared parking and alternative modes of transportation;
19. Provide sufficient, safe and accessible parks, plazas and greenways for active
and passive enjoyment; and
20. Improve the quality of air and water through provisions for the planting of
trees, bicycle parking and an urban form that reduces the need to drive.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.003. Boundaries of district established.
The boundaries of the SPI-18 Mechanicsville Neighborhood Special Public Interest District are shown on map Attachment B which by this reference is incorporated into and made a part of this chapter and this part. The Mechanicsville Neighborhood Special Public Interest District is divided into ten subareas as shown on said map Attachment B and are described as follows:
Subarea 1: Mechanicsville Mixed-Use Subarea 2: Fulton Mixed-Use Subarea 3: RDA Neighborhood Commercial Subarea 4: Multi-Family Subarea 5: Single-Family Subarea 6: Two-Family Subarea 7: Light Industrial Subarea 8: Heavy Industrial Subarea 9: Live-Work Subarea 10: McDaniel-Glenn Mixed-Use (Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.004. Application procedures.
A special administrative permit (SAP) application and seven copies each of a site plan, landscape plan and elevation drawings of each exterior façade shall be submitted, as applicable, and approved by the director of the bureau of planning prior to an applicant filing for a building permit. All exterior demolition, new construction (including additions to existing buildings), expansions of existing outdoor dining, outdoor dining within required sidewalk areas, or any construction which results in increased lot coverage, modification of the building footprint, or modification of building façades that alters the configuration of openings, shall be subject to said site plan and building elevation approval. Before making an application for a special administrative permit, a pre-application conference between the applicant and the director of the bureau of planning or the director's designee is required to discuss the application and relevant requirements of these regulations. Said pre-application conference shall be held within 14 days of the date of the request by the applicant, unless a longer period is mutually agreed upon. All applications for a SAP shall be processed in accordance with the standards and procedures applicable to said SAP applications contained in Chapter 25 of Part 16 except as otherwise modified by this Chapter 18.
Where regulations may require the approval of a SAP for other purposes so specified, processing by the director of the bureau of planning shall, without additional application, include consideration of other special administrative permits. Where such regulations require special exception or special use permit action, the special administrative permit for building permit purposes shall not be issued until the necessary approval has been obtained for special exception or special use permit.
The director of the bureau of planning may exempt certain classes of applications for special administrative permits from detailed review requirements as set forth upon written findings that generally within these districts, the actions proposed are of such a character or of such a scale as to make detailed reviews and approval by the planning director unnecessary. Where applications for special administrative permits are determined by reference to such findings to be thus exempted, the permit shall be issued if otherwise lawful.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07; Ord. No. 2018-11(18-O-1023), § 9.D, 5-16-18) Sec. 16-18R.005. Permitted principal uses and structures, permitted
accessory uses and structures, and special permits.
In all subareas, a building or premise shall be used for the following permitted principal uses, permitted accessory uses and structures, and special permits as follows:
1. Permitted principal uses:
a. For each subarea, a building or premises shall be used only for the principal purposes as indicated with a P in SPI-18 Mechanicsville: Use Table.
b. No use or manner of operation shall be permitted which is obnoxious or offensive by reason of odor, smoke, noise, glare, fumes, gas, vibration, unusual danger of fire or explosion, emission of particulate matter, or interference with radio or television communication, or is otherwise incompatible with the character of the district and its relation to adjoining districts.
c. Battery exchange stations shall be permitted where service stations are permitted.
2. Permitted accessory uses and structures:
Accessory uses and structures permitted within this district shall include those customarily accessory and clearly
incidental to permitted principal uses and structures and specifically include clubhouses, pools, and other recreation amenities, parking to serve authorized residential and non-residential uses within the district subject to the restrictions contained in Section 16-18R.021 and elsewhere in this chapter, and electric vehicle charging stations equipped with
Level 1, Level 2, and/or DC Fast Charge
EVSE.
3. Special use permits: The following uses are permissible only by additional special permits of the type indicated subject to limitations and requirements set forth in this chapter 18R or elsewhere in this
part, and subject to the applicable procedures and requirements set forth in section 16-25.001, et seq.
a. Special use permits: Special use permits shall be required as indicated with SUP in SPI-18 Mechanicsville: Use Table.
b. Special administrative permits:
Special administrative permits shall be required as indicated with SAP in SPI-18 Mechanicsville: Use Table.
c. Special exceptions: None.
SPI-18 MECHANICSVILLE: USE TABLE
P= Permitted Principal Uses & Structures PA= Permitted Accessory Uses & Structures SAP = Special Administrative Permits
SUP = Special Use Permit X = Not Permitted
* = Not to exceed 2,000 square feet ** = Not to exceed 8,000 square feet † =Farmers' market limited to parcels which meet the minimum lot size requirements and are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
Subarea 1: Mechanicsville Mixed-Use Subarea 2: Fulton Mixed-Use Subarea 3: RDA Neighborhood Commercial Subarea 4: Multi-family Subarea 5: Single-family Subarea 6: Two-family Subarea 7: Light Industrial Subarea 8: Heavy Industrial Subarea 9: Live Work Subarea 10: McDaniel-Glenn Uses 1 2 3 4 5 6 7 8 9 10 Adult businesses X X X X X X X X X X Bakeries and catering establishments including wholesale operations P P P* X X X P X P* P* Banks, savings and loan associations, and similar financial institutions P P P** X X X P P P* P** Barbershops, beauty shops and similar
personal service establishments P P P** X X X P X P* P** Bowling alleys P P X X X X P X X X
Broadcasting towers and line-of-sight relay devices for telephonic, radio or television communications greater than 70 feet in height, except alternative design mounting structures as contemplated by Section
16-25.002(3)(h)(iv)(i), and subject to Transitional height planes (Chapter 1, Section 19-1006)
SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP
Broadcasting towers and line-of-site relay devices for telephonic, radio or television communications 70 feet or less in height, and an alternative design mounting structures as contemplated by Section 16-25.002(3)(h)(iv)(i), and subject to Transitional height planes (Chapter 1, Section 19-1006).
SAP SAP SAP SAP SAP SAP SAP SAP SAP SAP
Business or commercial schools P P P* X X X P P X X Car washes SUP SUP X X X X SUP SUP X X
Child care centers, kindergartens and special schools P P P** SUP SUP SUP SUP X P** P** Churches, synagogues, temples and other
religious worship facilities of any size SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP Civil, service, garden, neighborhood or private clubs X X X SUP SUP SUP X X P* P*
Clubs and lodges X X X X X X X X X P= Permitted Principal Uses & Structures PA= Permitted Accessory Uses & Structures SAP = Special Administrative Permits
SUP = Special Use Permit X = Not Permitted
* = Not to exceed 2,000 square feet ** = Not to exceed 8,000 square feet † =Farmers' market limited to parcels which meet the minimum lot size requirements and are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
Subarea 1: Mechanicsville Mixed-Use Subarea 2: Fulton Mixed-Use Subarea 3: RDA Neighborhood Commercial Subarea 4: Multi-family Subarea 5: Single-family Subarea 6: Two-family Subarea 7: Light Industrial Subarea 8: Heavy Industrial Subarea 9: Live Work Subarea 10: McDaniel-Glenn Uses 1 2 3 4 5 6 7 8 9 10 Clinics (including veterinary), laboratories, and similar uses, but not blood donor stations except at hospitals. Veterinary clinics shall be located within soundproof buildings when located within 300 feet of any residential use.
P P P** X X X P P P* X
Commercial greenhouses SUP SUP SUP X X X SUP SUP SUP X Commercial recreation establishments including theaters, convention halls, places of assembly and similar uses
P P P** X X X P P P* X
Community centers SUP SUP SUP SUP X X SUP SUP SUP SUP Data centers, except where any part of the property is within 2,640 feet of a high-capacity transit stop, as referenced in City Code Section 16-28.014(14). X X X X X X P P X X Devices for the generation of energy, such as solar panels, wind generators and similar devices
PA PA PA PA PA PA PA PA PA PA
Dormitories, fraternity houses and sorority houses, officially affiliated with an accredited college, university or private school and only for the time period that such affiliation is in effect, such that loss of affiliation shall result in the loss of permission for the use
SUP SUP SUP X X X X X SUP X
Eating and drinking establishments. Drivethrough facilities are not permitted. P P P** X X X P P P* P** Farmers' market SAP SAP SAP SAP† SAP† SAP† SAP SAP SAP SAP Grocery stores P P P** X X X P P P** P
Guest houses, servant quarters or lodging facilities for caretakers or watchmen PA PA PA PA PA PA PA PA PA PA Home occupation (in Subareas 4, 5, 6, & 10 subject to limitations set forth in Section 16-29.001(17))
P P P PA PA PA X X P P
Hotels up to 30 rooms SUP SUP SUP X X X SUP SUP SUP X P= Permitted Principal Uses & Structures PA= Permitted Accessory Uses & Structures SAP = Special Administrative Permits
SUP = Special Use Permit X = Not Permitted
* = Not to exceed 2,000 square feet ** = Not to exceed 8,000 square feet † =Farmers' market limited to parcels which meet the minimum lot size requirements and are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
Subarea 1: Mechanicsville Mixed-Use Subarea 2: Fulton Mixed-Use Subarea 3: RDA Neighborhood Commercial Subarea 4: Multi-family Subarea 5: Single-family Subarea 6: Two-family Subarea 7: Light Industrial Subarea 8: Heavy Industrial Subarea 9: Live Work Subarea 10: McDaniel-Glenn Uses 1 2 3 4 5 6 7 8 9 10 Institutions of higher learning, including colleges and universities SUP SUP SUP SUP X X P P SUP X Junkyards, automobile salvage yards or scrap metal processors where such activity is wholly enclosed within a building
X X X X X X X P X X
Laundry and dry cleaning collection stations limited to no more than 5,000 square feet (in Subareas 7 and 8 no size limitation)
P P P* X X X P P P* P*
Laundry and dry cleaning establishments where customers operate equipment. P P P* PA X X P P P* P* Manufacturing, wholesaling, repairing not including automobile or heavy machinery, compounding, assembly, processing, preparation, packaging or treatment of articles, foods, components, products, clothing, machines and appliances and the like where the character of operations, emissions and by-products do not create adverse effects beyond the boundaries of the property. In Subareas 7 and 9, use of heavy drop hammers, punch presses or other machinery; or processing methods creating excessive noise or vibration is prohibited. In Subarea 9, no more than three persons shall be engaged in these uses, one of whom shall be a member of the family residing on the
premises; hours of operation shall be between 9:00 a.m. and 9:00 p.m.
X X X X X X P P P X
Market gardens P P P PA 1 PA 1 PA
1 P P P P
Multi-family dwellings (in Subarea 7 conversion of existing industrial buildings which are 50 years of age or older to multi-family is permitted)
P P P P X X X X P P
Museums, galleries, auditoriums, libraries and similar cultural facilities P P P** X X X X X P* P** P= Permitted Principal Uses & Structures PA= Permitted Accessory Uses & Structures SAP = Special Administrative Permits
SUP = Special Use Permit X = Not Permitted
* = Not to exceed 2,000 square feet ** = Not to exceed 8,000 square feet † =Farmers' market limited to parcels which meet the minimum lot size requirements and are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
Subarea 1: Mechanicsville Mixed-Use Subarea 2: Fulton Mixed-Use Subarea 3: RDA Neighborhood Commercial Subarea 4: Multi-family Subarea 5: Single-family Subarea 6: Two-family Subarea 7: Light Industrial Subarea 8: Heavy Industrial Subarea 9: Live Work Subarea 10: McDaniel-Glenn Uses 1 2 3 4 5 6 7 8 9 10 New and used car sales and rental X X X X X X X X X X Nursing homes, personal care homes, assisted living facilities, and rehabilitation centers.
Rehabilitation centers are not permitted in Subareas 4, 5 and 6
SUP SUP SUP SUP SUP SUP X X SUP SUP
Offices, arts and crafts galleries, and studios.
In Subarea 4, sales/leasing office for residential units permitted as accessory use.
In Subarea 9, no more than three persons shall be engaged in these uses, one of whom shall be a member of the family residing on the premises, and the hours of operation shall be between 9:00 a.m. and 9:00 p.m.
P P P** X X X P P P P**
Outdoor amusement enterprises, exhibits, entertainments, meetings, displays or sales areas (over 90 days)
SUP SUP SUP X X X SUP SUP SUP SUP
Outdoor amusement enterprises, exhibits, entertainments, meetings, displays or sales areas (under 90 days)
SAP SAP SAP X X X SAP SAP SAP SAP
Park-for-hire facilities—Independent structures with more than two stories above grade for the temporary storage of vehicles
SUP X X X X X X X X X
Park-for-hire surface parking lots on nonresidential uses in existence on 6/1/2013 and meeting the requirements of Sec.
16-18R.021(6)
X X PA PA PA PA X X PA X
Parking structures and surface lots (accessory) PA PA PA PA PA PA PA PA PA PA Parks and playgrounds P P P P P P P P P P Party houses provided that the use shall be prohibited within 150 feet of a property zoned
R-1, R-2, R-2A, R-2B, R-3, R-3A, R-4, R-4A, R-4B, R-5, RG, MR or a property used for residential purposes measured from property line to property line
SAP SAP SUP X X X X X X SAP
P= Permitted Principal Uses & Structures PA= Permitted Accessory Uses & Structures SAP = Special Administrative Permits
SUP = Special Use Permit X = Not Permitted
* = Not to exceed 2,000 square feet ** = Not to exceed 8,000 square feet † =Farmers' market limited to parcels which meet the minimum lot size requirements and are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
Subarea 1: Mechanicsville Mixed-Use Subarea 2: Fulton Mixed-Use Subarea 3: RDA Neighborhood Commercial Subarea 4: Multi-family Subarea 5: Single-family Subarea 6: Two-family Subarea 7: Light Industrial Subarea 8: Heavy Industrial Subarea 9: Live Work Subarea 10: McDaniel-Glenn Uses 1 2 3 4 5 6 7 8 9 10 Plumbing, tinsmithing, or cabinet shops, general service and repair establishments P P X X X X P P P* X Printing shops P P P** X X X P P P* X
Private greenhouses & garages PA PA PA PA PA PA PA PA PA PA Private schools P P P SUP SUP SUP P P P SUP Professional or personal service establishments, but not hiring halls P P P** x x x P P P* P** Public schools X X X P P P P P P P
Retail establishments (not including auto sales or rental). Drive-through facilities for package stores are not permitted.
P P P** X X X P P P* P**
Sales and repair establishments for home appliances, bicycles, lawn mowers, shoes, clocks and similar devices
P P P* X X X P P P* P*
Service Stations (automobiles), provided that no service station may be located within 1,500 feet of another service station. One shall be allowed west of Pryor Street in Subarea 1.
Prohibited west of Pryor Street in Subareas 2 and 3.
P P P** X X P P X X
Single-family dwellings P P P P P P X X P P Shelter SUP SUP SUP X X X SUP SUP SUP X
Short-term rentals, subject to the regulations in Atlanta City Code section 20-1001. P P P P P P X X P P Small discount variety stores, provided that no small discount variety store may be located within 5,280 feet of another small discount variety store.
P P P** X X X P P P
* P** Structures and uses required for operation of MARTA or a public utility P P P P P P P P P P Supportive housing P P P P X X X X P P
Swimming pools, tennis courts PA PA PA PA PA PA X X PA PA Tailoring, custom dressmaking, millinery and similar establishments P P P* X X X P P P* P* P= Permitted Principal Uses & Structures PA= Permitted Accessory Uses & Structures SAP = Special Administrative Permits
SUP = Special Use Permit X = Not Permitted
* = Not to exceed 2,000 square feet ** = Not to exceed 8,000 square feet † =Farmers' market limited to parcels which meet the minimum lot size requirements and are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
Subarea 1: Mechanicsville Mixed-Use Subarea 2: Fulton Mixed-Use Subarea 3: RDA Neighborhood Commercial Subarea 4: Multi-family Subarea 5: Single-family Subarea 6: Two-family Subarea 7: Light Industrial Subarea 8: Heavy Industrial Subarea 9: Live Work Subarea 10: McDaniel-Glenn Uses 1 2 3 4 5 6 7 8 9 10 Telecommunication switchboards, power generators and other telecommunications relay equipment and rooms or floors housing them.
Data centers are excluded from this use in this district.
X X X X X X P P X X
Two-family dwellings P P P P X P X X P P Urban gardens P P P SAP SAP SAP P P P P
Note:
1Market gardens are limited to parcels which are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13-07; Ord. No. 2008-62(06-O-0038), §§ 3N, 4N(1), 6P, 7-7-08; Ord. No.
2009-24(08-O-1251), §§ 2U, 2U(2), 6-9-09; Ord. No. 2009-61(09-O-1076), § 5(3), 10-13-09; Ord. No. 2011-39(10-O-1773), § 3Z, 9-15-11; Ord. No. 2013-57(13-O-1196), § 1, 11-13-13; Ord. No. 2014-53(14-O-1278), § 2(Attach. B), 12-10-14; Ord. No.
2015-02(14-O-1516), § 1, 1-29-15; Ord. No. 2014-22(14-O-1092), § 2-EE, 6-11-14; Ord. No. 2019-20(18-O-1679), § 11, 3-13-19;
Ord. No. 2019-66(19-O-1504), § 16, 12-11-19; Ord. No. 2020-58(19-O-1393), § 42, 10-28-20; Ord. No. 2021-60(21-O-0682), § 38, 12-15-21; Ord. No. 2024-36(24-O-1222), § 7, 9-4-24) Sec. 16-18R.006. Redevelopment requirements.
Subject to the provisions in Part 16, Chapter 24, Nonconformities.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.007. Transitional uses and yards.
1. Adjoining lot in same frontage: Where a lot in this district abuts a lot in any R-1 through R-G, MR, PD-H district, or SPI-18 Subareas 4, 5, 6, and 10 at the side along the same street frontage, and without an intervening street, such lot within this district, or the first 100 feet on such lot if it is wider than 100 feet, shall not be used for any drive-in facility, car wash, service station, repair garage, or paint and body shop even where otherwise specifically authorized.
2. Transitional height planes.
a. No portion of any structure shall protrude through a height limiting plane beginning the specified number of feet above the point set forth in subsection
16-18R.007(1)(b) below and extending inward over the SPI-18 district at an angle of 45 degrees. The following districts shall be considered protected districts
for purposes of this section 16-18R.007(1):
i. R-1 through R-5;
ii. RG-1 and RG-2;
iii. MR-1, MR-2, and MR-MU; and iv. Landmark, Historic, PD, and SPI districts and district subareas having uses and densities predominantly similar to those permitted in the district classifications listed in subsections (i) through (iii) above.
b. Proximity to districts and measurement applications:
i. For parcels in an SPI-18 district that are contiguous to a protected district, the transitional height plane shall be measured beginning 35 feet above the required SPI-18 setback or transitional yard adjoining the common property line with such protected district.
ii. For parcels in an SPI-18 district that are not contiguous to but are within 150 feet of a protected district, the transitional height plane shall
be measured beginning 15 feet above the nearest lot line of the protected district, provided this transitional height plane shall not extend more than 150 linear feet (measured along the ground) from the protected district up to and into the SPI-18 district. (See diagrams at section 16-29.001(62).)
c. The purpose and intent of this provision is to provide protection for the named
protected districts from nearby looming structures regardless of the presence of an intervening public right-of-way or park or space, public or private street or alley, or any lot or parcel remnant.
d. Transitional height plane measurements shall be applied to parcels on a point-bypoint basis and not average grade.
3. Transitional yards:
a. Where SPI-18 Subareas 1, 2, 3 and 9 adjoin an R-1 through R-G, or PD-H district or SPI-18 Subareas 4, 5 and 6 without an intervening street, a minimum of 20 feet is required which shall not be used for the purpose of parking, paving, loading, servicing or any other activity with the exception of private alleys or
drives a maximum of ten feet in width.
Where SPI-18 Subareas 7 and 8 adjoin an R-1 through R-G, or PD-H district or SPI-18 Subareas 4, 5 and 6 without an intervening street, a minimum of 20 feet is required which shall not be used for
the purpose of parking, paving, loading, servicing or any other activity. Such yards shall be planted as approved by the city arborist and maintained as a landscaped
strip.
b. Where SPI-18 Subarea 3 adjoins SPI-18 Subarea 4 no transitional yard or
permanent opaque wall are required when redevelopment occurs as part of a single development.
c. Screening: In addition to the above transitional yard requirements, permanent opaque walls six feet in height shall be provided and shall be maintained in sightly condition.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07; Ord. No. 2019-09(18-O-1581), § 10.15, 1-31- 19)
Sec. 16-18R.008. Development controls.
See SPI-18 Mechanicsville: Development Controls Table for Bulk Limitations, Maximum Building Coverage, Public Space Requirements, and Minimum Open Space Requirements.
For purposes of this chapter, and notwithstanding the provisions of code section 16-29.001(24), mixed-use development is defined as any development which contains as principal uses both residential and non-residential uses on the same development site, and in which each of such uses constitute at least 20 percent of the total floor area, excluding accessory uses. When either the total non-residential or residential floor area of a development is less than 20 percent of the total floor area, minimum residential useable open space requirements (UOSR) or public space requirements (PSR) shall not apply to said floor area.
1. Residential uses may utilize net lot area (NLA) or gross lot area (GLA) when
calculating maximum permitted residential floor area, provided that useable open space requirements (UOSR) are calculated based on the same lot
area.
2. Affordable new sales housing units or rental housing units requirements:
a. Affordable workforce housing bonus:
All or portion of the non-residential floor area ratio (FAR) may be utilized for residential purposes as indicated in SPI-18 Mechanicsville: Development Controls Table, provided that 20 percent or more affordable sales
or rental housing units are provided for that portion of residential units resulting from said utilization.
b. The mix of affordable studio, one bedroom, two bedroom, and three bedroom units shall be proportionally similar to the percentage bedroom mix in the overall development. The size of each affordable unit shall not be smaller than the
smallest unit for each unit type in the overall development. Said units shall be distributed evenly throughout the development and or building.
c. Affordable workforce housing shall have the maximum price or maximum rent set forth for moderate income housing units as defined in
Part 19, Chapter 1, section 19-1006.
d. Affordable workforce housing requirements shall be in place for a minimum of 15 years from the date of issuance of the occupancy permit and
shall include deed restrictions governing the value or rental rate placed on the affordable units.
e. No housing unit associated with a development project for which bonus FAR calculations were applied shall be issued an occupancy permit until such time as documentation is provided to the bureau of buildings establishing that the affordable workforce housing requirements have
been met and have been instituted as part of the warranty deed as an allowable exception to title for each affordable workforce unit that is a part of said development project.
3. Minimum open space requirements. There are no total open space requirements
(TOSR):
a. For residential uses, including all residential components of mixed use developments:
i. Open space requirements as indicated on Table I, "Land Use Intensity Ratios" shall be required for UOSR only, subject to additional requirements contained in subsection ii below for Subarea 10.
ii. In subarea 10, when a development spans public streets or contains non-contiguous parcels, credit for provided useable open space may be transferred
offsite to parcels within the development, provided that:
1) Both parcels are within SPI 18 subarea 10; and
2) Said open space is in excess of the minimum open space required for the donor parcel; and
3) Said open space is constructed at the same time as the residential components to which it is credited.
b. For nonresidential uses, including all non-residential components of mixed-use developments: Public Space requirements shall be as indicated in SPI-18 Mechanicsville: Development Controls Table. See section 16-28.012 for definitions and measurements. Required yards, sidewalks and supplemental zone widths that are constructed on private property may be counted towards this requirement. Such public space may
include planted areas, fountains, community gardens, parks plazas, hardscape elements related to sidewalks and plazas, and similar features located on private property.
c. For mixed-uses: The sum of minimum open space requirements specified in subsections a. and b. above for non-residential and residential
shall be met.
d. All buildings and structures built before 1950 shall have no Useable Open Space requirements or Public Space Requirements, provided that additions that increase the building footprint by more than ten percent of the pre-1950 footprint shall be subject to said requirements and that the entire development lot and floor
area shall be used in determining these requirements.
e. Residential balconies: Balconies for residential units, which are enclosed on not more than three sides, may be counted towards UOSR for a maximum depth of six feet.
4. Yards and supplemental zones: shall be as indicated in SPI-18 Mechanicsville: Development Controls Table.
5. For additional subarea requirements see SPI-18 Mechanicsville: Development Controls Table.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.009. Site limitations.
1. Minimum lot requirement: If a lot has less area of width than herein required and was a lot of record on the effective date of this part, that lot shall be used only for a single-family dwelling.
2. [Drive-through service windows and drive-in facilities.] Drive-through service windows and drive-in facilities shall not be located between the principal structure and the public or private street.
Drive through eating and drinking establishments, and package stores are prohibited.
3. Maximum building heights:
a. Subarea 1:
i. East of Central Avenue: 120 feet;
ii. West of Central Avenue and south of Richardson Street: 120 feet within 135 feet of the property line along Central Avenue, and 60 feet beyond 135 feet from the property line along Central Avenue;
iii. North of Richardson Street: 120 feet.
b. Subarea 2: 120 feet.
c. Subarea 3:
i. East of Central Avenue: 120 feet;
ii. West of Central Avenue and within 135 feet of the property line along Central Avenue: 120 feet;
iii. East of Pryor Street: 60 feet;
iv. All other areas: 40 feet.
d. Subarea 4:
i. The area bounded by Crumley Street, Fulton Street, Formwalt Street and Windsor Street: 60 feet;
ii. All other areas: 35 feet.
e. Subareas 5 and 6: 35 feet.
f. Subareas 7, 8 and 9: 35 feet within 150 feet of subareas 5 and 6, 60 feet between 150 and 300 feet of subareas 5 and 6, and 85 feet greater than 300 feet from subareas 5 and 6.
g. Subarea 10: 85 feet.
4. Minimum building facade heights: See SPI-18 Mechanicsville: Development Control Table.
SPI-18 MECHANICSVILLE: DEVELOPMENT CONTROLS TABLE Subarea
1 2 3 4 5 6 7 8 9* 10 Non-residential FAR (base) 1.00 2.50 1.50 None None None 2.00 2.00 0.50 0.505 Residential FAR
(base) 0.696 0.696 1.49 0.696 0.50 0.50 Existing buildings over 50 years of age None 0.696 0.696 Residential Affordable Housing FAR (bonus) 1.00 0.50 1.00 1.00 None None None None 1.30 1.00 Maximum Combined
FAR (without bonus) 1.696 3.196 2.99 0.696 0.50 0.50 2.00 2.00 1.196 1.196 Maximum Combined
FAR (with bonus) 2.696 3.696 3.99 1.69 N/A N/A N/A N/A 2.00 2.196 Maximum Building
Coverage (as % of NLA).
In subareas 5 and 6 maximum lot coverage shall be utilized (as % of NLA).
85% 85% 85% 85% 50% 50% 85% 85% 85% 85% Non-Residential Public Space Requirement (as a % of Net Lot Area) 10% or 20%1 10% or 20%1 None or 5%2 None None None None None 10% or 20%1 None Residential Useable Open Space Requirement (as a percent of Net Lot Area) See LUI chart See LUI chart See LUI chart See LUI chart None None None None See LUI chart See LUI Chart Minimum Facade
Height along Streets (measured in feet) 18 ft 18 ft 18 ft 18 ft None None None None 18 ft 18 ft Minimum Lot Size
(measured in square feet) None, except 2,450 sq ft for detached single-family and Twofamily None, except 2,450 sq ft for detached single-family and Twofamily None, except 2,450 sq ft for detached single-family and Twofamily 2,450 sq ft 2,450 sq ft 2,450 sq ft None None None, except
2,450 sq ft for detached single-family and Twofamily 800 sq ft Minimum Lot Width (measured in feet) None, except 35 ft for detached single-family and twofamily None, except 35 ft for detached single-family and twofamily None, except 35 ft for detached single-family and twofamily 40 ft 35 ft 40 ft 35 ft 40 ft 35 ft None None None, except 35 ft for detached single-family and twofamily None Subarea 1 2 3 4 5 6 7 8 9* 10 Supplemental Zone (width measured in feet) None or 5 ft when sidewalklevel residential None or 5 ft when sidewalklevel residential None or 5 ft when sidewalklevel residential 5 ft local street, or 9 ft collector/ arterial street Not required Not required 5 ft local street, or 9 ft collector/ arterial street 5 ft local street, or 9 ft collector/ arterial street 5 ft local street, or 9 ft collector/ arterial street 5 ft3 Front Yard (measured in feet) Not required Not required Not required Not required 15 ft or
match existing block face 15 ft or match existing block face Not required Not required Not required Not required Side Yard
(measured in feet) Not adjacent to street7 See foot note #4.
See foot note #4.
See foot note #4.
See foot note #4.
Block face average or 5 ft minimum Block face average or 5 ft minimum ≥ None None See foot note #4. None4 or5 ft Side Yard
(measured in feet) Adjacent to street see supplemental zone see supple- mental zone see supple- mental zone see supple- mental zone Half-depth
front yard per section 16-28.007 Half-depth front yard per section 16-28.007 see supplemental zone see supple- mental zone see supple- mental zone see supple- mental zone Rear Yard
(measured in feet) Not adjacent to street7 See foot note #4.
See foot note #4.
See foot note #4.
See foot note #4. 15 ft 15 ft None None See foot note #4.
7 ft or none when abutting a private alley7 Rear Yard (measured in feet) Adjacent to street see supplemental zone see supple mental zone see supple- mental zone see supple- mental zone Rear yards per section 16-28.007(e) Rear yards per section 16-28.007(e) see supple- mental zone see supple mental zone see supple- mental zone see supple- mental zone
1) Developments less than or equal to one-half acre - a minimum of ten percent of the net lot shall be public space. Developments greater than one acre - a minimum of 20 percent of the net lot shall be public space.
2) Development less than one acre - no open space requirements. Developments greater than one acre - a minimum of five percent of the net lot area shall be public space.
3) When a supplemental zone is adjacent to a multi-family building with no unit located above or below another residential unit, and when said zone meets the definition of a half depth front yard established in section 16-28.007(5)b, said supplemental zone shall have a minimum width of two feet.
4) Side or rear yard setback not adjacent to a street.
a. Nonresidential uses: none.
b. Residential uses, portions of buildings 35 feet in height or less: seven feet;
c. Residential uses, portions of buildings 35 feet to 52 feet in height: 15 feet;
d. Residential uses, portions of buildings above 52 feet in height: 20 feet;
e. Residential uses, facades with no windows adjacent to the side yard: none.
5) Non-residential floor area east of Ira Street and north of Glenn Street shall be limited to the first floor of a residential unit and shall not exceed 800 square feet in said unit. Non-residential uses not contained within a residential unit are prohibited.
6) Two-family dwellings shall only be permitted on lots greater than 40 feet in width.
7) In the case of zero-lot-line development, no side or rear yard is required along the internal lot line, provided that all other setback requirements from the external lot line shall apply.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13-07) Sec. 16-18R.010. Sidewalks.
Publicly accessible sidewalks shall be located along all public or private streets and shall have minimum widths as specified in SPI-18
Mechanicsville: Sidewalks Table. Sidewalks shall consist of two zones: A street furniture and tree planting zone and a clear zone. The following regulations shall apply to all public sidewalks:
1. Street furniture and tree planting zone requirements: The street furniture and
tree planting zone shall have a minimum width as specified in SPI-18 Mechanicsville:
Sidewalks Table. Said zone shall be located immediately adjacent to the curb and shall be continuous. Said zone shall meet the tree planting requirements of
section 16-18R.010(3). In addition to the required planting of trees, this zone may also be used for the placement of street furniture including utility poles, waste receptacles, fire hydrants, traffic signs, newspaper vending boxes, bus shelters,
bicycle racks and similar elements in a manner that does not obstruct pedestrian access or motorist visibility and as approved by the director of the bureau of planning.
2. Clear zone requirements: Said zone shall be located immediately contiguous to the street furniture and tree planting zone
and shall be continuous. Said zone shall be hardscape, and shall be unobstructed
for a minimum height of eight feet and for a minimum width as specified in SPI-18
Mechanicsville: Sidewalks Table, by any permanent or nonpermanent element.
3. Street tree planting requirements: Street trees are required and shall be planted in the ground a maximum of 30 feet on
center within the street furniture and tree planting zone and spaced equal distance between street lights. All newly planted trees shall be a minimum of three inches in caliper measured 36 inches above ground, shall be a minimum of 12 feet in height, shall have a minimum mature
height of 40 feet, and shall be limbed up to a minimum height of seven feet. Trees
shall have a minimum planting area of 32 square feet. All plantings, planting replacement and planting removal shall be approved by the city arborist. The area between required plantings shall either be planted with evergreen ground cover such as mondo grass or liriope spicata or shall be paved as approved by the director of
planning.
4. Tree grates: Tree grates are not required where all sidewalk width requirements
are met. Where tree grates are required or otherwise installed, they shall be a minimum of four feet by eight feet, shall be a type specified by the director of
planning in accordance with uniform design standards utilized by the director for placement of such objects in the public
right-of-way, and shall be placed within the street furniture and tree planting
zone. Where tree grates are not required or otherwise installed, tree planting areas shall be permitted to be planted with
evergreen ground cover such as mondo grass or liriope spicata.
5. Paving: Sidewalks shall be paved with concrete, brick or other decorative
hardscape material to match existing materials on each block face.
6. Nothing shall be erected, placed, planted or allowed to grow in such a manner as to impede visibility within visibility triangles at street intersections, as measured from the curb, between the heights of two and one-half feet and eight feet above
grade. See section 16-28.008(9), visibility at intersections.
7. No awning or canopy shall encroach beyond the clear zone.
8. Where property within this district abuts an R-1 through R-G, PD-H or MR district, or where an SPI-18 subarea abuts another SPI-18 subarea (with smaller sidewalks) without an intervening street, the sidewalk area within 20 feet of such districts shall taper as necessary to provide a smooth transition to the existing R-1
through R-G, PD-H, MR districts or SPI-18 subarea sidewalk. In the event that the
abutting R-1 through R-G, PD-H, MR district or SPI-18 subarea has no existing sidewalk, the sidewalk shall taper to a
width of six feet.
9. Decorative pedestrian lights: Where installed, shall be placed a maximum of 60 feet on center and spaced equidistant between street trees within the street furniture and tree planting zone. All said lights shall be Atlanta Type "C" as approved by the director of the bureau of planning.
10. Every commercially reasonable effort shall be made to place utilities underground or to the rear of structures to allow for
unobstructed use of sidewalks.
11. Trash receptacles or similar elements, where installed, shall be a type specified by the director of planning in accordance with uniform design standards utilized by the director for placement of such objects in the public right-of-way and shall be
placed within the street furniture and tree planting zone.
12. Outdoor dining within required sidewalk clear zone for pre-existing buildings: Buildings existing prior to the adoption of this ordinance with adjacent sidewalks that
do not meet the requirements of this chapter, may have outdoor dining that encroaches into the sidewalk provided the following criteria are met:
a. Shall have a minimum of eight feet of unobstructed sidewalk area adjacent to the curb when not located adjacent to on-street parking;
b. Shall have a minimum of six feet of unobstructed sidewalk area adjacent to the curb when located adjacent to on-street parking;
c. No permanent structure or ornamentation shall be located within the encroachment area and no element
shall be attached to the sidewalk in any way;
d. At such time as the outdoor dining use is discontinued, sidewalks shall comply with all requirements of this chapter; and
e. Outdoor dining may be separated from the sidewalk only with movable planters, fencing or similar nonfixed barriers provided they do not exceed a height of 36 inches including any plant material.
13. Outdoor dining within required clear zone for new construction: New developments
may have outdoor dining that encroaches into the sidewalk a maximum of two feet provided the following criteria are met:
a. No permanent structure or ornamentation shall be located within the encroachment area and no element
shall be attached to the sidewalk in any way;
b. At such time as the outdoor dining use is discontinued, sidewalks shall comply with all requirements of this chapter; and
c. Outdoor dining may be separated from the sidewalk only with movable planters, fencing or similar nonfixed barriers provided they do not exceed a height of 36 inches including any plant material.
SPI-18 MECHANICSVILLE: SIDEWALKS TABLE
Subarea 1 2 3 4 5 6 7* 8* 9 10 Street Furniture Zone Width (measured in feet). In subareas 4, 5, and 6 shall be provided on Ralph David Abernathy, Fulton, Pryor, and Central streets 5 ft 5 ft 5 ft None or 5 ft None or 5 ft None or 5 ft 5 ft 5 ft 5 ft 5 ft min.
Clear Zone Width (measured in feet). In subareas 4, 5, and 6 if street furniture zone is
provided, clear zone shall be six feet wide.
10 ft 10 ft 10 ft 6 ft local street, or 10 ft collector/arterial street 8 ft or match existing block face 8 ft or match existing block face 6 ft local street, or 10 ft collector/arterial street 6 ft local street, or 10 ft collector/arterial street 6 ft local street, or 10 ft collector/arterial street 6 ft min.
Street Trees Required Required Required Required Required
in front yard Required in front yard Required Required Required Required *In subareas 7 and 8, when no principal structure is located directly adjacent to a supplemental zone, the supplemental zone shall be landscaped with shrubs and trees in accordance with section 16-18R.019, minimum landscaping for surface parking lots, barrier requirements.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13-07) Sec. 16-18R.011. Supplemental zone for subareas 1, 2, 3, 4, 7, 8, 9 and 10.
See SPI-18 Mechanicsville: Development Controls Table for width requirements. For purposes of these regulations, the area between any building, parking garage, or parking lot and the required sidewalk, when no intervening building exists, shall be defined as the supplemental zone.
Supplemental zones shall meet the following requirements. Except as otherwise specified below, the square footage contained within a supplemental zone which meets all the following supplemental zone requirements may be counted towards UOSR or public space requirements.
1. Supplemental zone general requirements:
a. When sidewalk level residential units are provided, supplemental zone shall
be landscaped with the exception of terraces, porches, stoops and walkways, which may occupy a maximum of two-thirds of the supplemental
zone area;
b. Patio decks and off-street parking shall not be permitted within the supplemental zone;
c. The supplemental zone shall be no more than 24 inches above the adjacent public sidewalk for a minimum linear distance of 15 feet from the
nearest edge of the adjacent sidewalk, unless existing topographical considerations render this requirement unreasonable;
d. Any authorized walls surrounding landscaped and grassed areas shall not exceed a maximum height of 24 inches, except retaining walls, which shall not exceed a maximum height of 36 inches unless existing topography requires a retaining wall of greater height.
2. Supplemental zones containing a depth of 15 feet or less shall meet the following additional requirements:
a. No balcony shall encroach more than ten feet into the supplemental zone area.
b. Shall not be counted towards UOSR requirements unless visible and accessible to the general public from the adjacent public sidewalk, with
the exception of areas adjacent to sidewalk level residential units.
3. Supplemental zones containing a depth greater than 15 feet shall be counted
towards UOSR or public space requirements only when the following additional requirements are met:
a. Said zone shall permit and encourage pedestrians to walk on a minimum of 80 percent of its surface,
excluding fountains, pedestrian furniture, public art and similar elements.
b. When adjacent non-residential ground floor uses are provided, shall be visible and accessible from any point along 90 percent of any adjacent sidewalk.
c. When adjacent non-residential ground floor uses are provided, all sides of buildings fronting said zone shall meet the fenestration requirements of this chapter.
d. When adjacent residential ground floor uses are provided, shall provide a pedestrian walkway from said space to the adjacent public sidewalk.
Said pedestrian walkway shall be perpendicular to the street and shall connect directly to the public sidewalk and shall be open to the sky along its entire length.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.012. Relationship of building to street.
1. For purposes of this chapter, sidewalk-level shall be defined as any floor of a building with a finished-floor elevation less than or equal to five feet above the adjacent sidewalk or less than or equal to five feet below the adjacent sidewalk.
2. Active uses are required at sidewalk level along public and private streets, except at ingress and egress points into parking structures or loading areas. For the purposes of this chapter actives uses are limited to retail, office, residential, restaurant, museum, gallery, auditorium, library, hotel lobby, or cultural facility uses; all shall be serviced by plumbing, heating, and electricity.
Minimum active use depths from the street facing building façade shall be provided as follows:
a. Single-family, two-family or multi-family residential buildings with no residential units located above or below a unit:
Minimum depth of ten feet.
b. All other uses: Minimum depth of 20 feet.
c. When two or more floors meeting the definition of sidewalk-level exist within the same building, this requirement shall only apply to the frontage of each floor located within five feet above or below
the grade of the adjacent sidewalk.
3. The primary pedestrian entrance to all sidewalk-level uses:
a. Shall face, be visible from, and be directly accessible from the sidewalk.
b. When located along a street that functions as an arterial or collector, shall face, be visible from, and be directly
accessible from the sidewalk along such street, with the exception of singlefamily and two-family dwellings and multi-family buildings with no unit located above or below another residential unit.
c. Shall remain unlocked during business hours for non-residential uses.
d. Shall be at grade with the closest portion of the adjacent required sidewalk for
non-residential uses.
e. The use of fire-escape, entrance-only and exit-only doors as primary entrances is
explicitly prohibited.
f. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five
foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit.
This provision shall not apply to singlefamily and two-family residential structures.
4. Buildings containing residential uses shall:
a. Provide individual unit pedestrian entrances that are directly accessible from the sidewalk and opening directly onto the adjacent sidewalk, park, plaza, terrace, stoop or porch when a building
contains more than four sidewalk level residential units adjacent to the sidewalk, with the exception of assisted living facilities. All pedestrian walkways providing such access shall be primarily
perpendicular to the street, unless topography prohibits, and shall be permitted to share said walkway with one adjacent unit.
b. All residential uses not located at sidewalk level shall have pedestrian access to the sidewalk via a lobby fronting and accessible from said sidewalk.
c. Provide a pedestrian walkway a minimum of four feet wide linking pedestrian
entrances to the sidewalk.
d. Provide front porches, stoops or wheelchair ramps on the principal structure
pedestrian entrances, provided that:
i. Except as required in SPI-18 Subareas 5 and 6, front porches shall be a minimum of six feet wide and a minimum of five feet deep.
Front porches shall have roofs, balustrades and columns, and may be enclosed with screen wire, provided that the main characteristics of the porch such as balustrades, columns or porch railings, and front doors are visible.
Front porch columns, excluding railings or pickets, shall have a minimum width of eight inches.
ii. Stoops shall be a minimum of three feet wide and faced in brick or stone.
iii. Steps serving porches or stoops facing the street shall have enclosed risers and ends.
e. Residential fenestration treatment. All street-fronting façades, shall meet the
following requirements:
i. Windows shall be provided for a minimum of 30 percent and a maximum of 50 percent of the total façade, with each façade being calculated independently.
ii. Equally sized vertical windows shall be arranged horizontally.
iii. Windowpanes shall be recessed a minimum of three inches from the adjacent façade. In single-family and two-family structures windowpanes shall be recessed a minimum of two inches from the adjacent façade where wood or cementious siding are used.
iv. Fenestration shall not utilize painted glass, reflective glass or other
similarly treated or opaque windows.
5. Storefront fenestration treatment (for parking deck requirements see section 16-18R.017(3)).
All street-fronting non-residential uses, with the exception of churches and fire stations, shall meet the following sidewalk-level requirements:
a. The length of façade without intervening fenestration or entryway shall not exceed 20 feet.
b. Fenestration shall be provided for a minimum of 65 percent of the length of all street frontages:
i. Beginning at a point not more than three feet above the sidewalk, to a height no less than ten feet above the sidewalk or;
ii. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation
when the finished floor elevation is two or more feet above the sidewalk;
or iii. Beginning at a point not more than sidewalk level, to a height no less than ten feet above the finished floor elevation when the finished floor elevation is below the sidewalk.
c. Fenestration shall not utilize painted glass, reflective glass or other similarly treated or opaque windows. Entrances
may be counted towards fenestration requirements.
6. Building floors shall be delineated to the third story above sidewalk level and lower and shall be executed through windows, belt courses, cornice lines or similar architectural detailing.
7. A street address number shall be located directly above or beside the primary building and business establishment entrances along the required sidewalk, shall be clearly visible from the sidewalk and shall be a minimum of six inches in height.
8. Chimneys:
a. Shall begin at-grade.
b. Shall be faced with brick, horizontal wood clapboard siding, horizontal hardiplank (cementious siding), stone, cast stone, or three-part hard coat stucco.
9. Awnings and canopies:
a. All awnings and canopies shall be cloth or canvas.
b. Internally lit awnings and canopies are prohibited.
10. Sidewalk arcades are not permitted.
11. A fence, retaining wall, curb or hedge with a minimum height of six inches shall be provided at the back of the sidewalk adjacent to sidewalk-level residential units, with the exception of openings to access steps, drives or pedestrian walkways.
12. Retaining walls shall be provided at the back of the sidewalk adjacent to sidewalk level residential units where similar retaining walls exists on adjacent lots, subject to subsection 15.
below.
13. Fences and walls shall meet the following regulations:
a. For residential uses adjacent to the sidewalk, fences shall not exceed four feet in height when located between the primary building and the street or between any supplemental zone and the adjacent
street. For non-residential uses adjacent to the sidewalk, fences are prohibited
when located between the building and the sidewalk except where specifically authorized elsewhere in this chapter for outdoor dining.
b. Retaining walls located adjacent to a sidewalk along a public street shall not exceed a height of two feet and the
combined height of a fence where otherwise authorized and retaining wall shall not exceed a height of five feet, unless existing topography prohibits retaining walls of a lesser height. Retaining walls shall be faced with stone, brick or smooth stucco. See section
16-29.001(25)(b).
c. No walls, except retaining walls, shall be located between the street and any building, with the exception of screening for authorized off-street loading areas.
d. Fences and walls located between the primary building and the lot line and not exceeding six feet in height may be
erected, but shall not be permitted between the primary building and the street.
e. Fences adjacent to the street shall be of picket-wood, stone, composite materials
or ornamental metal. The finished side or front side of one-sided fences shall face the public or private street.
f. No barbed wire, razor wire, chain link fence or similar elements shall be visible from any public plaza, ground level or
sidewalk level outdoor dining area or public right-of-way.
14. Gasoline fuel dispenser structures, canopies, and associated service areas shall not be located between a building and the street, except for those service stations located in Subarea 1, where gasoline fuel dispenser structures, canopies, and associated service areas may be located between the building and the street. A landscaped buffer shall be provided between all driveways adjacent to the fuel pump area and the street-fronting sidewalk. All required landscaped areas shall be planted with evergreen groundcover or shrubs with a maximum height of 30 inches, and all landscaped buffer areas and strips along sidewalks, drives, private streets and public rights-of-way shall have a minimum of one single-stem tree planted per 30 feet of length with a minimum caliper of three and one-half inches.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07; Ord. No. 2015-44(15-O-1275), § 1, 9-17-15;
Ord. No. 2026-05(26-O-1001), § 10, 2-25-26) Sec. 16-18R.013. Façade materials.
Building façade materials shall consist of the following:
1. Single and two-family: All exterior façades shall be brick, horizontal wood clapboard siding, or horizontal hardiplank (cementious siding).
2. [Multi-family.] Multi-family building with no unit located above or below another
residential unit:
a. All exterior façades adjacent to a public street shall be brick, wood, stone, cast stone, three-part hard coat stucco, horizontal wood clapboard siding or hardiplank (cementious siding).
b. All exterior façades not adjacent to a public street shall be brick, stone, cast stone, three-part hard coat stucco, concrete masonry units, splitfaced concrete, split-faced brick, horizontal wood clapboard siding,
or horizontal hardiplank (cementious siding).
3. All other multi-family and non-residential:
a. All exterior façades adjacent to a public street shall be brick, stone, cast stone or three-part hard coat stucco.
b. All exterior façades not adjacent to a public street shall be brick, stone, cast stone, three-part hard coat stucco, concrete masonry units, splitfaced concrete, split-faced brick, horizontal wood clapboard siding,
or horizontal hardiplank (cementious siding).
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.014. Signage.
Refer to section 16-28A, sign ordinance.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.015. Loading areas, loading dock entrances and building mechanical and accessory features.
1. Loading areas: Dumpsters and loading areas shall be paved with impervious materials and shall be screened so as not to be visible from any public plaza, ground level or sidewalk level outdoor dining area, public sidewalk or public right-of way. In addition, dumpsters and loading areas serving residential uses shall be enclosed with opaque walls six feet in height.
2. [Loading dock entrances.] Loading dock entrances for non-residential uses shall be screened so that loading docks and related activity are not visible from the public right-of-way.
3. Building mechanical and accessory features:
a. Shall be located to the side, rear, or roof of the principal structure and shall be in the location of least visibility from the public right-of-way. Screening with plant or fence materials shall be required if the equipment is otherwise visible from the
public right-of-way.
b. When located on rooftops shall be incorporated in the design of the building and screened with building materials
similar to the building.
c. Shall not be permitted between the building and any public street.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.016. Off-street loading requirements.
See table of loading requirements, section 16-28.015, off-street loading requirements.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.017. Driveway curb cuts, driveways and parking structures.
1. Driveway curb cuts:
a. All sidewalk paving materials shall be continued across any intervening driveway curb cut at the same prevailing grade
and cross slope as on the adjacent sidewalk clear zone.
b. Shall be a maximum of 24 feet for twoway entrances and 12 feet for one-way entrances, unless otherwise permitted by the commissioner of transportation.
c. Maximum permitted number of driveway curb cuts for each development, subject to the provisions of section 16-25.002(3):
i. Developments with only one street frontage, which is less than 300 feet in length: one;
ii. Developments with only one street frontage, which is greater than 300 feet in length: two;
iii. Developments with more than one street frontage: one located on each street frontage, provided that curb cuts shall not be permitted on arterial or collector streets when access may be provided on other streets
with adjacent land uses similar to that of the subject property.
iv. For the purposes of this Section, two curb cuts serving two one-way driveways shall only be counted as one curb cut.
d. Shall not be permitted on any street that functions as an arterial street or collector street when access may be provided from a side or rear street located
immediately adjacent to a contiguous property, with the exception of hotel patron drop-off drives.
2. Driveways:
a. No circular drives shall be located between any building and any public street with
the exception of hotels, childcare centers, kindergartens, and special schools subject to the provisions in section 16-25.002(3).
b. Unless authorized by section 16-18R.017(2)(a), driveways, except for a driveway to reach the side yard or rear
yard or an on-site parking facility, are not permitted between the sidewalk and
a building, and shall be perpendicular to any adjacent street.
c. All contiguous ground-floor residential units shall share one common drive,
located in rear yards or side yards without street frontage, to serve garages, carports and parking areas.
d. Independent driveways are not required when access is provided to a private
alley. For single and two-family dwellings independent driveways are not required.
e. Private alley shall be defined as a minimum of 24 feet wide mid-block access easement connecting two streets, having
a minimum of eight feet wide paved area, adjacent to single and two family uses
and 24 feet paved area for all other uses.
Parking is not permitted in the alley.
Where garage doors or parking areas are set back from the alley, its width may be reduced to 20 feet, provided 24 feet exists between parking areas or garage doors.
f. Notwithstanding the provisions of section 16-28.006(10), a common or joint driveway may be authorized by the director of the bureau of planning when adjacent lots have direct vehicular access to a street, and a driveway from a private street which functions as a public street may be authorized by the director of the bureau of planning, based on traffic
considerations, when a perpetual easement agreement is agreed upon by all affected property owners and a copy of
such agreement is provided to the bureau of planning.
3. Parking structures: In addition to section 16-28.028, the following regulations shall apply:
a. Shall have the appearance of a horizontal storied building.
c. Shall meet the active use requirements of section 16-18R.012(2); or
d. When topographical conditions prevent the parking deck treatment requirements of section 16-18R.012(2) from being met, a continuous minimum five feet
wide landscaped strip shall be provided between the structure and the public sidewalk, except at ingress and egress points into the structure. The landscaped strip shall be planted with street trees spaced a maximum distance of 20 feet on
center, which shall also meet the tree requirements in section 16-18R.010. The landscape strip shall also be planted with evergreen ground cover such as mondo grass, liriope spicata, ivy or evergreen shrubs with a maximum mature height of 24 inches. All plantings, planting replacement and planting removal shall be approved by the city arborist.
4. [Entrances to garages and carports that serve a single residential unit.] Entrances to garages and carports that serve a single residential unit, and which are located less than 20 feet behind the building façade of the principal structure, shall face the rear yard or a side yard which has no street frontage.
5. [All developments, including parking decks.]
All developments, including parking decks, shall have walkways a minimum width of four feet connecting ground level parking to the public sidewalks and to all building entrances. See section 16-18R.019, minimum landscaping for parking lots and barrier requirements.
6. No drop-off lanes shall be permitted along public streets. Where on-street parking is provided, certain parking spaces may be utilized as dropoff lanes, when permitted by the commissioner of transportation.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07; Ord. No. 2008-67(08-O-0196), § 11, 7-21-08;
Ord. No. 2020-33(20-O-1381), § 34, 6-23-20) Sec. 16-18R.018. Lighting, security, and maintenance requirements.
1. All lighting including all parking decks and lots and lit canopies shall reduce light spillage onto residentially used properties by providing cutoff luminaries which have a maximum 90 degree illumination.
2. All lighting that up-lights trees, buildings or other elements, shall be located a minimum height of eight feet above the sidewalk, driveway or pedestrian area when not located within completely landscaped areas.
3. All parking facilities shall be maintained in a clean, safe and sanitary condition. Parking spaces and driving lanes shall be clearly defined and maintained as such. Parking lots shall not be operated when any damage impairs the drivability of the parking lot. See section 16-28.014 for additional requirements.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.019. Minimum landscaping for surface parking lots, barrier requirements.
The requirements of City of Atlanta Code of Ordinances, Chapter 158 Vegetation, Article II Tree Protection, section 30, parking lot requirements shall apply to this district except as modified as follows:
1. Said parking lot requirements shall apply to all lots regardless of size;
2. All parking bays shall be terminated with a landscaped strip a minimum width of five feet and equal to the length of the parking bay;
3. All required landscaped areas shall be planted with evergreen groundcover or
shrubs with a maximum height of 30 inches; and
4. All landscaped buffer areas and strips along sidewalks, drives, private streets and public rights-of-way shall have a
minimum of one tree planted per 30 feet of length with a minimum caliper of three and one-half inches.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.020. Minimum bicycle parking and showering facilities
requirements.
See section 16-28.014(6), Bicycle parking requirements.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07; Ord. No. 2019-09(18-O-1581), § 12, 1-31-19) Sec. 16-18R.021. Off-street parking
requirements.
In addition to the provisions of section 16-28.008(7), which shall apply and are
incorporated herein, the following parking requirements shall apply to all uses approved by special permits as well as permitted uses. See also sections 16-28.013 and 16-28.014:
1. Off-street surface parking:
a. Shall not be located between a building and the street without an intervening building;
b. Shall be accessory to a permitted principal use only, provided that parking spaces serving another principal permitted use may use such facility for shared parking as specified in section 16-18R.021(5) below.
2. For office uses:
a. A maximum of two and one-half spaces for each 1,000 square feet of floor area. Parking during off-peak hours (after 6:00 p.m.) may be shared for other uses as permitted in section 16-18R.021(5);
b. All office developments over 100,000 square feet shall reserve and designate at least five percent of the employee parking spaces "Carpool Only." Carpool spaces shall be used only by carpool vehicles in which at least two of the persons are employees or tenants of the building. Such spaces shall be located near the building's employee
entrance or other preferable locations within the employee parking areas as approved by the department of transportation; and
c. All new parking structures shall be built to accommodate vanpool access.
The minimum ceiling height for vanpools is eight feet two inches.
3. For residential uses:
a. Minimum parking requirements:
i. Multi-family: As specified in Table 1, "Land Use Intensity Ratios" under appropriate FAR for the development.
ii. Single and two-family: None.
b. Maximum parking spaces:
i. For resident parking, one parking space per bedroom for up to two bedrooms and one-half
parking space for each bedroom unit of three and above may be provided per dwelling unit.
ii. For visitor parking, one-third parking space per dwelling unit may be provided.
4. For non-residential uses:
a. Subarea 10 east of Ira Street and North of Glenn Street: Items "B" through "P" below notwithstanding, no more than one off-street parking space shall be provided for nonresidential uses.
b. Banks, savings and loan institutions, and the like: A minimum of one space for each 200 square feet of
floor area and a maximum of two and one-half spaces for each 200 square feet of floor area.
c. Business colleges, trade schools, conservatories, dancing schools, and the like: A minimum of one space for each 200 square feet of floor area and a maximum of two and one-half spaces for each 200 square feet of floor area.
d. Child care centers, day care centers, pre-kindergartens, play and other
special schools or day care centers for young children: A minimum of one space for each 600 square feet of floor area and a maximum of two and one-half spaces for each 600 square feet of floor area. In addition to providing off-street parking, such establishments shall provide safe and convenient facilities for loading and unloading children, as approved by the commissioner of the department of transportation.
e. Clubs, lodges, and commercial recreational establishments: A minimum of one space for each 200 square feet of floor area and a maximum of two and one-half spaces for each 200 square feet of floor area.
f. Dormitories, fraternity houses and sorority houses. One space for two beds plus one space for each 200 square feet of floor area designated or occupied other than for sleeping purposes.
g. Eating and drinking establishments:
i. Indoor requirements: A minimum of one space for each 100 square feet of floor area and a maximum of three spaces for each 100 square feet of floor area;
ii. Accessory outdoor dining which is 25 percent or less than the total gross floor area of the building or business, and is not covered with a permanent structure: A maximum of one and three-fourths spaces for each 100 square feet of floor area.
iii. Accessory outdoor dining which exceeds 25 percent of the total gross floor area of the building or business shall have the following minimum requirements:
A minimum of one space for each 100 square feet area and a maximum of one and threefourths spaces for each 100 square feet of the total accessory outdoor dining floor area including the 25 percent nonexempt floor area.
h. Fraternities, sororities: One space for two beds plus a minimum of one space for each 200 square feet of floor area and a maximum of two and one-half space for each 200 square feet of floor area designated or occupied other than for sleeping purposes.
i. Hotels and motels: A minimum of one space for each 600 square feet of floor area and a maximum of two and one-half spaces for each 600 square feet of floor area.
j. Nursing homes, personal care homes, assisted living facilities, and rehabilitation centers: A maximum of one space for four beds.
k. Printing shops: A minimum of one space for each 200 square feet of floor area and a maximum of two and one-half spaces for each 200 square feet of floor area.
l. Retail establishments, including bakeries, delicatessens, catering, clothing and tailor shops: A minimum of one space for each 300 square feet of floor area and a maximum of two and one-half spaces for each 300 square feet of floor area.
m. Schools, colleges, churches, recreation or community centers and other places of assembly: One space for each four fixed seats (with 18 inches if bench length counted as one seat) or one space for each 35 square feet of enclosed floor area for the accommodation of movable seats in the largest assembly room, whichever is greater, plus the following:
i. Public or private elementary or middle school: A maximum of two spaces for each classroom.
ii. High school: A maximum of four spaces for each classroom.
iii. Colleges and universities: A maximum of eight spaces for each classroom.
n. For all other non-residential uses: A minimum of one parking space for
each 300 square feet of floor area shall be provided on the site and a maximum of two spaces for each 300 square feet of floor area.
o. Shelter: One parking space for each on duty staff member, whether paid or unpaid. In addition to staff parking, a space of sufficient size is required for each van, bus or other
vehicle used by the facility and one additional parking space shall be provided for each 2,000 square feet of the facility.
5. Reduction or transfer of parking requirements: The director of the bureau of planning may reduce parking requirements only upon a determination that shared or off-site parking arrangements
may be permitted by the director of the bureau of planning subject to the following criteria:
a. The character or use of the building is such as to make unnecessary the full provisions of parking facilities;
or
b. That the applicant has established a valid shared or off-site parking arrangement. Said shared or offsite parking arrangement shall avoid conflicting parking demands and
provide for safe pedestrian circulation and access. Additionally, all shared or off-site parking spaces
shall be clearly marked and signed as reserved during specified hours.
An applicant shall submit the following information establishing conformance to the above criteria in
order to share or transfer parking requirements and avoid conflicting parking demands:
i. A to-scale map indicating location of all proposed parking spaces;
ii. Indicate hours of business operation(s);
iii. Written consent of all property owners agreeing to the shared or off-site parking arrangement;
iv. Copies of parking leases for shared or off-site parking arrangements. Renewed leases shall be provided to the director of the bureau of planning.
Lack of a current lease shall automatically terminate the special exception authorization.
6. Notwithstanding any provision of the City of Atlanta Code of Ordinances to the
contrary, park-for-hire surface parking lots are prohibited. Accessory parking decks built to satisfy the parking requirements of this section shall be permitted to be used as park-for-hire parking decks.
Park-for-hire parking decks built to provide parking spaces in excess of the parking requirements of this section 16-18R.021 shall only be permitted as a primary use through the special permit process as authorized in section 16-18R.005. Existing surface parking lots accessory to non-residential principal uses as of 6/1/2013 may be used for park-forhire operations during events at Turner Field. Said operations shall be accessory to the principal use and shall only be
permitted where such park-for-hire operation possesses:
a. A valid business license; and
b. A park-for-hire permit authorized by Article XVII of Chapter 30 of the Atlanta City Code.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07; Ord. No. 2008-62(06-O-0038), §§ 4N(2), 6P(1), 7-7-08; Ord. No. 2009-24(08-O-1251), § 2U(3), 6-9-09; Ord. No. 2013-57(13-O-1196), § 2, 11-13- 13; Ord. No. 2020-33(20-O-1381), § 35, 6-23-20) Sec. 16-18R.022. Membership in
transportation management associations and transportation management plans.
Any development that has an office component greater than 100,000 square feet of total gross leasable floor area of space shall become a member of an existing Transportation Management Association (TMA), which provides service to the area or shall provide a Transportation Management Plan (TMP) with the criteria listed below. The bureau of buildings shall not issue occupancy permits for any development in this district until such time as the developer or leasing agent for each of the components has submitted to the director of the bureau of planning, written confirmation of TMA membership or has submitted a Transportation Management Plan. The local TMA may assist with the preparation of the TMP.
The TMP shall contain strategies to reduce single occupancy vehicle trips generated by the project and shall be based on an annual commute mode survey. Said survey shall be based on a continuous five-day workweek for all estimated employees arriving at the work site and for all residents leaving the residential site between 6:00 a.m. and 10:00 a.m., Monday through Friday.
Based upon the survey information, the employer and residential manager shall develop a TMP, which shall include, but not be limited to:
1. Commute alternatives:
a. Incentives for public transit ridership such as transit cards;
b. Carpooling and vanpooling;
c. Commuter bicycling and walking programs;
d. Alternative work hours:
i. Staggered work hours;
ii. Compressed work weeks;
iii. Flexible work hours (flextime);
iv. Telecommuting.
2. Transportation demand strategies:
a. Improvements to alternative modes such as vanpooling;
b. Financial incentives given to employees who use commute alternatives;
c. Parking management programs;
d. Commute alternatives information and marketing;
e. Shared parking arrangements;
f. Provision for a mixture of uses onsite;
g. Pedestrian links to adjacent uses.
3. A program to promote and maintain employee participation in carpooling, vanpooling, and use of mass transit, including a method of monitoring the number of ride sharers and their travel patterns.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.023. Pedestrian bridges and tunnels.
Pedestrian bridges and tunnels are prohibited when located above or below public streets, private streets which function as public streets connecting two other public streets, or other public rights-of-way.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.024. Zero-lot-line development.
Zero-lot-line subdivision is permitted for residential uses in Subareas 1, 2, 3, 4, 6, 9 and 10 provided the minimum lot size established in the SPI-18 Mechanicsville: Development Controls Table is provided.
The additional requirements of section 16-28.007 shall also apply.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
Sec. 16-18R.025. Additional requirements for subareas 5 and 6.
The following additional requirements apply to all properties located within subareas 5 and 6.
Please refer to the SPI 18 Mechanicsville: Development Controls Table and the SPI 18 Mechanicsville: Sidewalks Table, and section 16- 18R.017, driveway curb cuts, driveways and parking structures for additional requirements.
1. Front yard general requirements:
a. Front yard setback: setbacks shall be no closer to the public or private street than the closest and no farther from the street than the farthest building built before 1945 of like use on that side of the block.
b. Patio decks shall not be permitted within the front yard or half-depth front yard;
c. Off-street parking shall not be permitted within the front yard or halfdepth front yard.
d. Driveways shall extend 20 feet beyond the front facade of the principal structure and shall have a maximum width of ten feet in the front yard.
2. All front facades, front porches, front steps and front doors of the principal structure shall face and be parallel to the lot frontage. Wrap around front porches are permitted.
3. The primary pedestrian entrance of the principle structure:
a. Shall face and be visible from a public or private street and shall be located on the front facade.
b. Each individual unit shall be linked to the sidewalk with a pedestrian walkway which shall be between three and four feet wide.
c. Front doors shall be comprised of rectangular wood and glass panels consisting of a two-thirds wood lower portion and one-third glass upper portion, or shall be a solid wood door with two or three wood panels.
4. Porches:
a. Front porches on the principal structure shall be required, and shall be a minimum of 50 percent of the width
of the house with a minimum depth of eight feet. Porches may be enclosed with screen wire only, provided that the main characteristics of the porch such as balustrades,
columns or porch railings, and front doors are visible;
b. Side porches in the half-depth front yard shall be a minimum of four feet in depth. Porches may be enclosed by glass windows or screen wire only, provided all the main features of a porch are maintained in place.
c. Porches, terraces and stoops shall have a maximum finished floor height of 24 inches above finished-grade, unless existing topographical considerations render this requirement unreasonable, subject to the provisions in section 16-25.002(3);
d. Porches shall not extend more than ten feet into the front yard and five feet into the half-depth front yard.
e. Porches facing a public or private street shall consist of the following:
i. Steps shall have closed risers and ends and cheek walls. Said check walls shall consist of masonry, brick, three-part hard coat stucco or stone to match the
foundation material of the principal structure. Access ramps shall be located on the side elevation.
ii. Railings, columns, and posts shall not consist of unpainted wood or ornamental metal, and shall have the following minimum dimensions:
a) Columns and posts shall be a minimum of six inches wide and shall have base and cap components.
b) Pickets shall be at least two inches wide and two inches deep.
c) Railings shall include top and bottom horizontal members. The top railing shall consist of two elements. The upper element shall measure two inches
by six inches and the lower element shall measure two by four inches. The bottom railing shall measure two inches by four inches.
5. Patio decks, balconies and upper level terraces:
a. Patio decks shall be permitted only when located to the rear of the principal structure and shall be permitted at any level.
b. Balconies and upper level terraces shall be permitted.
6. Limitations on projections into required yards and open spaces shall be in conformance with section 16-28.008.
7. Roofs:
a. North of Ormond Street, the roof form above the front facade of the principal structure shall be front gabled and/or hipped. Roof pitch shall be a minimum of 8:12. Roof pitch
above porches shall not be restricted.
b. Roofing material shall be asphalt shingles, or metal when existing houses on the same block have metal roofs.
c. Skylights shall be located in the rear only.
8. Fenestration:
a. North of Ormond Street:
i. Any facades that face a public or private street shall consist of fenestration that shall be no less than 15 percent and no greater than 40 percent of the total surface wall area. Facades that do not face a public or private street shall consist of
fenestration that shall be no less than ten percent of the total surface wall area. Windows may be individual or grouped. No individual window
unit shall exceed 28 square feet.
Within each individual window unit, no individual window sash, either fixed or operable, shall exceed 16 square feet.
ii. Windows shall be double-hung.
iii. Each double-hung window shall be surrounded by wood trim between four and six inches wide and shall include a bottom sill.
Windows grouped together shall have center mullions two inches wider than the side trim.
b. South of Ormond Street: Any facades that face a public or private street shall consist of fenestration
that shall be no less than 15 percent and no greater than 80 percent of the total surface wall area. Facades that do not face a public or private street shall consist of fenestration that shall be no less than ten percent of the total surface wall area.
c. Height of window sills on the public or private street fronting facade shall be no less than two and one-half feet and no more than three and one-half feet above finished floor elevation.
Windows on said facade shall have a minimum height of three feet.
d. All windows shall include windowpanes recessed a minimum of two inches from the adjacent facade, unless the facade is constructed as a glass curtain wall. Glass curtain walls
shall not be permitted north of Ormond Street.
e. Flat "snap-in" muntins and muntins sandwiched between layers of glass are prohibited.
9. Façade materials shall consist of horizontal wood clapboard siding, horizontal hardiplank siding (cementious siding), brick, or stone. Painted wood fish-scale style shingles are permitted on the face of gables.
10. Chimneys:
a. Shall begin at-grade.
b. Shall be faced with brick, horizontal wood clapboard siding, horizontal
hardiplank (cementious siding), stone, cast stone, or three-part hard coat stucco.
11. Foundations:
a. The first floor of the principal structure, including public or private street-facing porches, shall be on foundations and elevated above the grade between two and four feet, unless existing topography is greater, as measured at the front façade of the structure. Slab on grade is not permitted.
b. Foundations shall constitute a distinct building design element and shall contrast with the front façade material. Brick, stone, or three-part hard coat stucco shall be permitted.
Standard, unfinished concrete block and stacked stone is prohibited.
12. Garage entrances are prohibited on the front façade. Single car-width garage
entrances shall be permitted on the half depth front yard façade of the structure.
Double car-width garage entrances shall be permitted only on the rear façade of the structure.
13. Accessory structures, such as carriage houses, smoke houses, tenant and alley
houses, private garages, carports, and mechanical equipment shall be located to the side and/or rear of the principal
structure within the buildable area of the lot and shall not project beyond the front of the principal structure. Accessory
structures shall not exceed 20 feet in height and 22 feet in width. If mechanical equipment is visible from a public street, screening with appropriate plant or fence materials is required.
14. Fences: The finished side or front side of one-sided fences shall face the public or private street.
15. Retaining walls shall be provided at the back of the required sidewalk where retaining walls exist on adjacent lots. Said walls shall match the height of the
adjacent retaining walls, unless existing typography requires the wall height to
change.
16. Asphalt paving is prohibited for walkways and driveways.
17. Building height:
a. Elevators or stairways constructed to access the roof shall not extend higher than ten feet above the roof line of a flat roof. Said elevator or stairway shall not exceed ten percent of the horizontal floor area of the roof, or 50 square feet, which ever is less.
b. Parapet walls shall not extend more than 42 inches above the roof line of a flat roof.
18. Grading:
a. Grading shall not excessively or unnecessarily alter the natural topography of the site, with the exception of grading necessary to protect and preserve the structural integrity of a structure.
b. New grades shall meet existing topography in a smooth transition, and shall not be increased.
(Ord. No. 2007-67(07-O-1792), § 1(Att. A), 11-13- 07)
CHAPTER 18S. SPI-19 (VINE CITY
SPECIAL PUBLIC INTEREST DISTRICT)
Sec. 16-18S.001. Scope of provisions.
The regulations set forth in this chapter or set forth elsewhere in this part when referred to in this chapter, are the regulations of the Vine City Special Public Interest District (SPI-19). These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in Section 16-18S.003, except that all existing categories of historic protection designated pursuant to Chapter 20 of Part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this chapter.
Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. The SPI-19 Vine City regulations shall take precedence over the Atlanta Zoning
Ordinance whenever a conflict between the two exists. When specific reference is not provided in the SPI ordinance, the Atlanta Zoning Ordinance, as amended, shall apply.
The regulations set forth in sections 16-18S.001 through section 16-18S.019 shall apply to all properties located within the SPI-19 Vine City, including all subareas within the district.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.002. Statement of intent.
The intent of the council in establishing SPI-19 as a zoning district is as follows:
1. Preserve, protect and foster the redevelopment of Vine City through the integration of transportation and land planning in a way that balances local, regional,
and state economic benefits;
2. Preserve and protect Vine City's historic buildings and sites as recognized by the inclusion of several buildings on the
National Register of Historic Places;
3. Encourage the development of housing that provides a range of opportunities for citizens within the district;
4. Encourage a compatible mixture of residential, commercial, industrial, cultural and recreational uses;
5. Create an urban environment where people can live, work, meet and play;
6. Promote pedestrian safety by providing for pleasant and convenient sidewalk
level pedestrian circulation that minimizes impediments by vehicles;
7. Encourage the use of MARTA and other public transit facilities;
8. Enhance the efficient utilization of accessible and sufficient parking facilities in an unobtrusive manner, including
encouraging shared parking and alternative modes of transportation;
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.003. Boundaries of district established.
The boundaries of the SPI-19 Vine City are shown on map Attachment B which by this
reference is incorporated into and made a part of this chapter and this part. The SPI-19 Vine City is divided into 11 subareas as shown on said map Attachment B and which are described as follows.
The intent of these standards is to establish clear minimum development standards, allow for the orderly progression of development, and provide flexibility over time without compromising the goals and objectives of SPI-19.
SPI-19 Vine City Subareas 1 - Historic Westside Village 2 - Martin Luther King, Jr. Drive - Lowery Boulevard
3 - Morris Brown 4 - Northside Drive 5 - Vine City Low Density Residential 6 - Vine City Single Family Residential 7 - Vine City Medium Density Residential 8 - Boone-Lowery Corridor
9 - Magnolia Low Density Mixed Use 10 - Vine City Neighborhood Commercial 11 - Maple and Electric Avenue Table 1: Vine City Subareas (Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.004. Application procedures.
1. A special administrative permit (SAP) application and a specified number of copies of a site plan, landscape plan, and elevation drawings of each exterior facade shall be submitted, as applicable, and approved by the office of zoning and development prior to filing for a building permit. All exterior demolition, new construction (including additions to existing buildings), new or expanded outdoor dining, or work which results in increased lot coverage, modification of the building footprint, or modification of building facades that would reduce the configuration of street facing openings, shall be subject to said SAP approval. All applications for an SAP shall be processed in accordance with the standards and procedures applicable to said SAP applications contained in Chapter 25 of Part 16 except as otherwise modified by this Chapter 18S. No SAP shall be issued until after such time any other required special use permit or board of zoning adjustment action has been obtained.
2. Provisions for administrative variations from regulations:
a. As part of general action when plans require approval of an SAP, the director of the office of zoning and development
may authorize variations from regulations generally applying based on written findings that either:
i. A plan proposed by an applicant, while not strictly in accord with regulations applying generally within the district, satisfies the public purposes and intent, and provides public protection to an equivalent or greater degree; or ii. In the particular circumstances of the case, strict application of a particular regulation or regulations is not necessary for the accomplishment of public purposes or the provision of public protection, at the time or in the future.
b. Notation concerning the existence of such variation shall be made by written findings of SAP approval to be filed in the office of zoning and development as public record. Variances and special exceptions shall be required from the board of zoning adjustment in cases such as, minimum
transitional yards, transitional height planes, minimum open spaces, maximum building height, maximum fence height and loading requirements, and signage limitations.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.005. Redevelopment requirements.
Any property wherein 60 percent or greater of the principal building is removed or destroyed by any means shall be redeveloped in accordance with the requirements of this chapter
notwithstanding any other provisions in Part 16, Chapter 24 to the contrary. Destruction made necessary by repairs, maintenance and/or remodeling shall not be construed to be removal or destruction.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.006. Permitted principal uses and structures.
1. See SPI-19 Use Table for permitted principal and accessory uses and special permits.
2. Permitted principal uses:
a. A building or premise shall be used only for the principal purposes as indicated
with a P in the SPI-19 Use Table.
b. For the purposes of this chapter, uses at sidewalk-level in what would otherwise
be classified as an independent primary parking structure shall not constitute principal uses.
3. Permitted accessory uses and structures:
Accessory structures and uses permitted within this district shall include those indicated with a PA in the SPI-19 Use Table as well as those customarily accessory and clearly incidental to permitted principal uses and structures and specifically includes parking to serve authorized residential and non-residential uses within the district, subject to the restrictions contained in this chapter.
a. Accessory uses in Subarea 5 shall be located on the ground floor of a building containing a principal use and shall not occupy more than 50 percent of the ground floor area.
b. Accessory structures shall be placed to the rear of the principle structure and
shall not exceed 80 percent of the height of the principal structure.
c. Accessory structures shall be located so as to minimize the view from the public
right-of-way.
4. Special use permits and special administrative permits: Special use permits shall be required as indicated with SUP and Special Administrative Permits as indicated with SAP in the SPI-19 Use Table. These uses shall be subject to the limitations and requirements set herein or elsewhere in this part, and subject to the applicable procedures and requirements set forth in Section 16-25.001 et seq.
5. Prohibited uses: Any principal use and structure not specifically listed in the SPI-19 Table of Uses is prohibited in this district. The Director is authorized to determine the classification of a use listed in this district where such use is combined with another use or the classification of the use does not meet an applicable definition. Additionally:
a. No use or manner of operation shall be permitted which is obnoxious or offensive by reason of odor, smoke, noise, glare,
fumes, gas, vibration, unusual danger of fire or explosion, emission of particulate matter, or interference with radio or
television communication, or is otherwise incompatible with the character of the
district and its relation to adjoining districts.
Table 2: SPI-19 Use Table Subarea Subarea 2 Subarea 3 Subarea 4 Subarea 5 Subarea 6 Subarea 7 Subarea 8 Subarea 9 Subarea 10 Subarea 11
PERMITTED USE
Accessory Dwelling Units
X X X PA PA PA X X X X X
Bakeries & Catering, including wholesale operations
P P P P X X X P P P P
Banks, S&L and similar financial institutions
P P P P X X X P P P P
Barber & Beauty shops & similar personal services
SUP SUP SUP SUP X X X SUP SUP SUP SUP
Bed & Breakfast Inn
X X X X X P^ X X X X P
Broadcasting Towers & line-orsight relay devices (telephones, radio, tv)
SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP Business or Commercial Schools P P P P X X X P P
* P
* P Car Washes X X X SUP X X X SUP SUP SUP SUP Child care centers,
kindergarten & special schools
SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP Churches,
Synagogues, Temples, Mosques & religious worship facilities
SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP Civil, service,
garden, neighborhood or private clubs
SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP Clubs & Lodges P P P P X X X P X X P
Commercial Greenhouses
SUP SUP SUP P X X X P X X P
Commercial Kitchen
X X P X X X X X X X X
Commercial Recreation, Theatres, Convention Halls, Assembly Halls
P P P
* P X X X P P P P
Table 2: SPI-19 Use Table Subarea Subarea 2 Subarea 3 Subarea 4 Subarea 5 Subarea 6 Subarea 7 Subarea 8 Subarea 9 Subarea 10 Subarea 11
PERMITTED USE
Community Centers, Community Services, Recreational Centers
SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP Devices for generation of energy,
solar panels, wind generators, similar
PA PA PA PA PA PA PA PA PA PA PA
Dormitories, fraternity houses & sorority houses
SUP SUP P SUP X X X SUP X X SUP
Eating & Drinking Establishments
P P P P X X P
* P P
* P
* P Farmers' Market SAP SAP SAP SAP SAP SAP SAP SAP SAP SAP SAP Grocery Stores P P P P X X X P P
* P
* P Guest House, Servant Quarters, Lodging for caretakers/watchmen
PA PA PA PA PA PA PA PA PA PA PA
Hotels up to 30 Rooms
SUP SUP SUP P X X X P X X P
Hotels more than 30 Rooms
X X X P X X X P X X X
Institutions of higher learning, colleges & universities
SUP SUP P SUP SUP SUP SUP SUP SUP SUP SUP Laundry & dry
cleaning & Collection Stations, no more than 5,000 sf
P P P P X X X P P P P
Market Gardens X X P X PA 1 PA 1 PA 1 PA
1 X X X
Multi-family dwellings P P P P P X P P P P P Museums, Galleries, Auditoriums,
Libraries & similar Cultural Facilities
P P P P X X X P P P P
Nursing Homes & Convalescent Centers
SUP SUP SUP SUP X X X SUP SUP SUP SUP
Table 2: SPI-19 Use Table Subarea Subarea 2 Subarea 3 Subarea 4 Subarea 5 Subarea 6 Subarea 7 Subarea 8 Subarea 9 Subarea 10 Subarea 11
PERMITTED USE
Offices, Arts & Crafts galleries and studios
P P P P X X P
* P P
* P
* P Outdoor Amusement, exhibits, entertainment, meetings (>90 days)
SUP SUP SUP SUP X X SUP SUP SUP SUP SUP
Outdoor Amusement, exhibits, entertainment, meetings ("90 days)
SAP SAP SAP SAP X X X SAP X X SAP
Park for Hire structure with > 2 stories above grade for temp. vehicle storage
SUP SUP SUP SUP X X X SUP X X SUP
Parking structures & surface lots (accessory)
PA PA PA PA X X PA PA PA X PA
Parks & Playgrounds
P P P P P P P P P P P
Party houses provided that the use shall be prohibited within 150 feet of a property zoned
R-1, R-2, R-2A,
R-2B, R-3, R-3A,
R-4, R-4A, R-4B,
R-5, RG, MR or a property used for residential purposes measured from property line to property line
SAP SAP SAP SAP X X X SAP SAP SUP SAP
Personal Care Homes
SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP Plumbing, tinsmithing, cabinet
shops, service & repair establishments
P P P P X X X P P P P
Table 2: SPI-19 Use Table Subarea Subarea 2 Subarea 3 Subarea 4 Subarea 5 Subarea 6 Subarea 7 Subarea 8 Subarea 9 Subarea 10 Subarea 11
PERMITTED USE
Printing Shops P P P P X X X P P P P Private Greenhouses & Garages
PA PA PA PA PA PA PA PA PA PA PA
Private Schools P P P P P SUP SUP P P P P Professional or
Personal Service Establishments, not hiring halls
P P P P X X X P P P P
Public Schools P P P P P P P P P P P Retail Establishments (except auto sales or rental)
P P P P X X P
* P P P P
Sales & repair for home appliances, bicycles, lawn mowers, shoes, clocks
P P P P X X X P P
* P
* P Shelter SUP SUP X SUP X X X SUP X X SUP Short-term rentals, subject to the regulations in Atlanta City Code section 20-1001.
P P P P P P P P P P P
Single-Family dwellings
P P P P P P P P P P P
Supportive Housing P P P P P X P P P P P Swimming Pools,
Tennis Courts
PA PA PA PA PA PA PA PA PA PA PA
Tailoring, Custom Dressmaking, Millinery & similar
P P P P X X X P P
* P
* P Two-Family Dwellings X X P X P X X X X X X Urban Gardens P P P P P
* P
* P
* SUP SUP SUP P
Uses and Structures SAP = Special Administrative Permits SUP = Special Use Permit SEP = Special Exception Permit X = Not Permitted
* = Not to Exceed 4,000 Square Feet Table 2: SPI-19 Use Table Subarea Subarea 2 Subarea 3 Subarea 4 Subarea 5 Subarea 6 Subarea 7 Subarea 8 Subarea 9 Subarea 10 Subarea 11
PERMITTED USE
^ Permitted only in the Sunset Avenue Historic District (Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11-20; Ord. No. 2020-58(19-O-1393), § 43, 10-28-20; Ord. No. 2021-60(21-O-0682), § 39, 12-15-21; Ord. No. 2024-20(23-O-1611), § 2, 6-12-24) Sec. 16-18S.007. Development controls.
See SPI-19: Development Controls Table for Bulk Limitations, Building and Lot Coverage, Open Space Requirements, Yard Requirements, and Height Requirements.
For purposes of this chapter, and notwithstanding the provisions of Code Section 16-29.001(24), mixed-use development is defined as any development which contains as principal uses both residential and non-residential uses on the same development site, and in which both of such uses are at least 20 percent of the total floor area, excluding accessory uses.
Table 3: SPI-19 Development Control Table Development
Controls Subarea 1 Subarea 2 Subarea 3 Subarea 4 Subarea 5 Subarea 6 Subarea 7 Subarea 8 Subarea 9 Subarea 10 Subarea 11 Subarea 12 Maximum
FAR
a) Residential
2.00 2.00 3.20 3.20 1.00 0.5 1.50 1.48 0.696 0.8 2.00 2.00
b) Non - Residential
1.00 1.00 3.00 4.00 N/A None None 2.50 1 1 2.00 2.00 c)
Combined
3.00 3.00 6.20 7.20 N/A N/A N/A 3.99 1.696 1.8 4.00 4.00 Maximum
Building Coverage 85% 85% 85% 85% 70% 70% 70% 85% 85% 85% 85% 85% Open
Space Requirements
a) Nonresidential Open Space Requirements None or 5%** None or 5%** None or 5%** 10% or 20%* None None None or 5%** None or 5%** None or 5%** None or 5%** None or 5% None or 5% b) Residential Useable Open Space Requirement LUI LUI LUI LUI None None LUI LUI LUI LUI LUI LUI Minimum
Building Height 18' 18' 18' 35' 18' 18' 18' 18' 18' 18' 18' 18' Maximum
Building Height 55' 55' 55' 105' 40' 35' 40' 55' 40' 40' 55' 55' Minimum
Lot Size (sq. ft) None None None None 1,000 sf 2,500 sf 2,000 sf None None None None None Minimum
Frontage (ft) None None None None 20' Frontage width to conform to the existing, predominant block face pattern.
20' None None None None None Table 3: SPI-19 Development Control Table Development
Controls Subarea 1 Subarea 2 Subarea 3 Subarea 4 Subarea 5 Subarea 6 Subarea 7 Subarea 8 Subarea 9 Subarea 10 Subarea 11 Subarea 12 Setbacks 5' 5' 5' 5' 3' or match existing block 3' or match existing block 5' 5' 5' 5' 5' 5' a) Minimum Street Furniture Zone (width in ft)
b) Clear Zone (width in ft) 10' arterials & collectors. 6' all other streets.
10' arterials & collectors. 6' all other streets.
10' arterials & collectors. 6' all other streets.
10' arterials & collectors. 6' all other streets.
5' or match existing block 5' or match existing block 10' arterials & collectors. 6' all other streets.
10' arterials & collectors. 6' all other streets.
10' arterials & collectors. 6' all other streets.
10' arterials & collectors. 6' all other streets.
10' arterials & collectors. 6' all other streets.
10' arterials & collectors. 6' all other streets.
c) Minimal Supplemental Zone (width in ft) 5' 5' 5' 5' None None None or 3' when sidewalk level use is residential 5' 5' 5' 5' 5' d) Minimum Front Yard (ft)*** Not Required Not Required Not Required Not Required Match existing block face Match existing block face Match existing block face Not Required Not Required Not Required Not Required Not Required e) Minimum Side Yard (ft) not adjacent to street None or 5ft # None or 5ft # None or 5ft # None or 5ft # 5' 5' 5' None or 5ft # None or 5ft # None or 5ft # None or 5ft # None or 5ft# f) Minimum Side Yard (ft) adjacent to street See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone Half depth of front yard per section 16-28.007 (5)(b) Half depth of front yard per section 16-28.007 (5)(b) Half depth of front yard per section 16-28.010 See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone g) Minimum Rear Yard (ft) not adjacent to street None or 20ft^ None or 20ft^ None or 20ft^ None or 20ft^ None or 20ft^ 7' or matching existing block None or 20ft^ None or 20ft^ None or 20ft^ None or 20ft^ None or 20ft^ None or 20ft^ h) Minimum Rear Yard (ft) adjacent to street See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone See Supplemental Zone Table 3: SPI-19 Development Control Table Development
Controls Subarea 1 Subarea 2 Subarea 3 Subarea 4 Subarea 5 Subarea 6 Subarea 7 Subarea 8 Subarea 9 Subarea 10 Subarea 11 Subarea 12 Transitional Height Requirements Required Required Required Required N/A N/A Required Required Required Required Required See Supplement al
Required Zone Notes:
* Developments < or = 0.5 acre - a minimum of 10% of the net lot shall be public space. Developments > 1 acre - a minimum of 20% of the net lot area shall be public space.
** Development < 1 acre - no open space requirements. Developments > 1 acre - a minimum of 5% of the net lot area shall be public space.
LUI: See Land Use Intensity Chart #None for residential units without windows or non-residential uses. 5' for residential uses with windows.
None for residential units without windows or non-residential uses. 20' for residential uses with windows.
#*Height shall not exceed 240' even when available bonuses are applied. Transitional Height Requirements: where required see Section 16-29.062
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11-20; Ord. No. 2024-16(23-O-1610), § 2, 4-24-24) Sec. 16-18S.008. Site limitations.
1. Cul-de-sacs are prohibited. However, midblock roadways constructed to provide future connectivity between public streets shall not be considered a cul-de-sac.
2. Developments with more than 600 feet of frontage along a single street shall be divided by public or private streets into blocks having a maximum length of 600 feet, as measured from the back the of the sidewalk clear zone or required supplemental zone. Such streets shall function as public streets and shall connect two other public streets or private streets
3. New streets incentive. New public streets, or private streets which function as public streets may be counted towards public space requirements provided the following criteria are met:
a. Connects two other public streets or private streets which meet the requirements of items b, c, and d below; and
b. Meets the requirements of sections 16-18S.010 and 16-18S.011; and
c. The maximum width shall be 36 feet which shall include, two on-street parallel parking lanes, two travel lanes and sidewalk extensions at intersections and shall have granite curbs; and
d. When adjacent to a park area, new streets shall meet all above requirements along
each park edge.
e. Gates shall not be permitted across said streets
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.009. Transitional uses and yards.
1. Adjoining lot with same frontage: Where SPI-19 Subareas 1, 3, 4, 8 and 11, adjoin an R-1 through R-G, or PD-H district or SPI-19 Subareas 5, 6, 7, 9 and 10 at the side along the same street frontage, and without an intervening street, such lot within this district, or the first 100 feet on such lot if it is wider than 100 feet, shall not be used for any drive-through service window or drive-in facility, car wash, service station, mortuary or funeral home, sales lot for automobiles, repair garage, or paint and body shop even where otherwise specifically authorized.
2. Transitional height planes: Where SPI-19 Subareas 1, 3, 4, 8 and 11 adjoin an R-1 through R-G, or PD-H district or SPI-19 Subareas 5, 6, 7, 9, and 10 with or without an intervening street, height within this district shall be limited by the Transitional Height Plane requirements as defined in section 16-29.001.
3. Transitional yards:
a. Where SPI-19 Subareas 3 and 4 adjoin an R-1 through R-G, or PD-H district or SPI-19 Subareas 5, 6, 7, 9, and 10 without an intervening street, a minimum of 20
feet is required which shall not be used for the purpose of parking, paving, loading, servicing or any other activity with the exception of private alleys or drives a maximum of ten feet in width. Such
yards shall be planted as approved by the city arborist and maintained as a landscaped strip.
b. Screening: In addition to the above transitional yard requirements, permanent opaque walls six feet in height shall be provided and shall be maintained in sightly condition.
4. Zero-lot-line development. Zero-lot-line subdivision is permitted for multifamily residential uses provided a minimum of 800 square feet in lot area is provided.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.010. Sidewalks.
Sidewalks shall be located along all public and private streets and shall have the components and widths specified in the SPI-19 Development Controls Table. The following regulations shall apply to all sidewalks:
1. Sidewalks shall consist of at least two zones, a street furniture zone and a clear zone.
a. The street furniture zone shall be located immediately adjacent to the curb. Said zone shall be used for the required planting of trees and the placement of street furniture including waste receptacles, fire hydrants, traffic signs, newspaper vending
boxes, bus shelters, bicycle racks and similar elements in a manner that does not obstruct pedestrian access or motorist visibility and as approved by the Director of the Office of Zoning and Development.
b. The clear zone shall be located immediately contiguous to the street furniture zone and shall be continuous. Said zone shall be unobstructed for a minimum height of eight feet
and shall have a consistent crossslope not exceeding two percent.
2. Street trees are required along all streets and shall be planted in the street furniture zone.
a. All streets where no trees exist, new trees shall be planted in the ground
a maximum of 30 feet on center within the street furniture zone and spaced equal distance between street lights. All newly planted trees shall be a minimum of three inches in caliper measured 36 inches above ground, shall be a minimum of 12 feet in height, shall have a minimum mature height of 40 feet, and shall be limbed up to a minimum height of seven feet. Trees shall have a minimum planting area of 40 square feet. All plantings, planting replacement and planting removal shall be approved by the city arborist. The
area between required plantings shall either be planted with evergreen ground cover such as mondo grass or liriope spicata or shall be paved.
3. Decorative Pedestrian Street lights, where installed, shall be placed approximately 60 feet on center and spaced equidistant between required street trees. Where
installed, said lights shall be located within the street furniture zone. Applicant shall coordinate with the Department of
Public Works regarding the final decision of the proposed layout.
4. No awning or canopy shall encroach into the street furniture zone.
5. Trash receptacles or similar elements, where installed, shall be a type specified by the director of zoning and development in accordance with uniform design standards utilized by the director for
placement of such objects in the public right-of-way and shall be placed within the street furniture zone.
6. Entryway doors shall not open into the clear zone.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.011. Supplemental zone.
For purposes of these regulations, the area between any building, parking garage, or parking lot and the required sidewalk, when no intervening building exists, shall be defined as the supplemental zone. Supplemental zones shall meet the following requirements. Except as otherwise specified below, the square footage contained within a supplemental zone which meets all the following supplemental zone requirements may be counted towards public space requirements.
1. Supplemental zone general requirements.
a. Where sidewalk level residential units are located, the supplemental zone shall be landscaped with the exception of terraces, porches, stoops and walkways, which may occupy a maximum of two-thirds of the supplemental zone area;
b. Terraces, porches and stoops shall have a maximum finished floor height of 36 inches above finished grade, unless existing topographical considerations render this requirement unreasonable;
c. The supplemental zone shall be no more than 24 inches above the adjacent public sidewalk, unless existing topographical considerations render this requirement unreasonable; and
2. Developments of greater than one acre in area and adjacent to existing transit
stops which have no shelters shall provide a shelter within the supplemental zone
for a minimum of one such stop. The design and location of such stop shall be approved by the Director of the Office of Zoning and Development.
3. Fences and walls shall meet the following regulations:
a. For residential uses adjacent to the sidewalk, fences shall not exceed 42 inches in height when located between the primary building and the street, or between any supplemental zone and the adjacent street. For non-residential uses adjacent to the sidewalk, fences are prohibited when located between the building and the sidewalk except where specifically authorized elsewhere in this chapter for outdoor dining.
b. Retaining walls located adjacent to a sidewalk along a public street shall not exceed a height of 36 inches. The combined height of a fence, where otherwise authorized and retaining wall shall not exceed a height of 42 inches, unless existing topography prohibits retaining walls of a lesser height. Retaining
walls shall be finished poured concrete or shall be faced with stone, brick or smooth stucco. See section 16-29.001(25)(b) for definition of retaining wall.
c. No walls, except retaining walls, shall be located between the street and any building, except for screening for authorized off-street loading areas.
d. Fences and walls between the primary building and the lot line may be erected but shall not exceed six feet in height and are not permitted between the primary building and the street.
e. For outdoor dining, movable planters, movable fencing, or similar movable barriers are allowed to separate outdoor dining from the sidewalk,
provided they do not exceed a height of 36 inches, including any plant material.
f. Barbed wire, razor wire, and chain link fencing are prohibited permanent fencing materials.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.012. Relationship of building to street.
1. Delineation of building floors at the third story above sidewalk level and lower shall be articulated through windows, belt courses, cornice lines or similar architectural detailing.
2. The primary pedestrian entrance for access to all sidewalk level uses and business establishments with public or private street frontage
a. Shall face and be visible from the public street when located adjacent to such
street. When located adjacent to a street that functions as an arterial street or a collector street, said entrance shall face and be visible from such street.
b. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five
foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit.
This provision shall not apply to singlefamily and two-family residential structures.
3. A street address number shall be located directly above the primary building entrance, shall be clearly visible from the sidewalk and shall be a minimum of six inches in height.
4. Fenestration:
a. Street-fronting non-residential uses, with the exception of churches and fire stations, along streets that function as arterial streets and collector streets shall meet the following sidewalk level requirements:
i. The length of the facade without intervening fenestration or entryway shall not exceed 20 feet.
ii. Fenestration shall not utilize painted glass, reflective glass or other
similarly treated or opaque windows.
Entrances may be counted towards fenestration requirements.
iii. Fenestration shall be provided for a minimum of 65 percent of the length
of all street frontages:
1. Beginning at a point not more than three feet above the sidewalk, or
2. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three or more feet above the sidewalk;
or
3. Beginning at a point not more than sidewalk level, to a height no less than ten feet above the finished floor elevation, when the finished floor elevation is below the sidewalk.
b. Fenestration shall be provided for a minimum of 30 percent of the length of the sidewalk level frontage for residential uses on all streets and for non-residential uses, with the exception of churches and fire stations, on all streets other than streets that function as arterial streets and collector streets.
5. Buildings with residential uses at the sidewalk level, shall meet the following regulations:
a. All primary pedestrian entrances not adjacent to a public sidewalk shall be linked to the public sidewalk with a pedestrian walkway a minimum of five feet wide.
b. Such buildings shall have windows at sidewalk-level or on each street frontage which are substantially similar in size to the sidewalk level front facade windows.
6. Siding and foundation:
a. A building's 16-18 street facing facade should have a maximum of two different
cladding materials, excluding the fenestration material.
b. Single family and two-family: All exterior facades shall be brick, wood, or Hardiplank, (cementitious siding). Hardiplank siding shall be a maximum of six inches
in width.
c. Multi-family, mixed use, and nonresidential:
i. All exterior facades adjacent to a public street, public park, and/or trail shall be brick, Hardiplank (cementitious siding) stone, cast stone, architectural metal panels, or true stucco.
d. All exterior facades not adjacent to a public street shall be brick, stone, cast stone, true stucco, concrete masonry units, split-faced concrete, or split-faced block.
e. Single-family and two-family: foundations are required in Subareas 5 and 6 and shall be finished with brick, smooth stucco, or smooth finish concrete at least two feet above grade.
7. Active use provisions along arterial and collector streets. The following additional provisions shall apply:
a. For the purposes of this chapter active uses shall be serviced by plumbing, heating, and electricity and are limited to residential, retail, eating and drinking establishments, museum, gallery, office, institutional, auditorium, library, hotel lobby, or cultural facility uses, and shall not include parking, non-residential storage areas, driveway or queuing lanes parallel to the adjacent street.
b. Active uses shall be provided for a minimum depth of 20 feet, as measured from the sidewalk-level building facade.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20; Ord. No. 2026-05(26-O-1001), § 11, 2-25-26) Sec. 16-18S.013. Signage.
Sign regulations shall be the same as 16-28.010(41).
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.014. Dumpsters, loading areas and entrances, mechanical and accessory
features.
1. Off-street loading requirements shall be in accordance with the provisions of section 16-28.015 of the Atlanta Zoning Ordinance.
2. Dumpsters and loading docks shall not be located between any building and the street, public park, and/or trail and shall be located in the side or rear yard, screened from public view with opaque walls or fences a minimum of six feet in height, and paved with impervious materials.
3. Where provided, all loading spaces shall provide vertical clearance of 14 feet and shall not be located within the required sidewalk. Building mechanical and accessory features:
a. Shall not be permitted between the building and any public street and public park;
b. Shall be located to the side or rear of the principal structure and shall not be visible from the public right-of-way. Screening with plant or building materials shall be required where the equipment would
otherwise be visible from the public rightof-way.
c. When mechanical and accessory equipment is located on building roofs, they shall be incorporated into the design of the building and screened with building
materials similar to the building, such as a penthouse or parapet wall.
4. Gasoline fuel dispenser structures and associated vehicular services, such as air pumps and car washes, shall not be located between a building and the street.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.015. Driveways, curb cuts, parking and drivethrough facilities.
1. Driveways:
a. Driveways are not permitted between the sidewalk and a building, and shall be perpendicular to any adjacent street,
except for a driveway to reach the side yard or rear yard or an on-site parking facility.
b. Entrances to garages and carports that serve a single residential unit, and are not located behind the principal structure, shall face the rear yard, or a side yard which has no street frontage.
c. All contiguous ground-floor residential units shall share one common drive,
located in rear yards or side yards without street frontage, to serve garages, carports and parking areas.
d. All sidewalk paving materials shall be continued across any intervening driveway at the same prevailing grade and cross
slope as on the adjacent sidewalk clear zone.
e. No circular drives shall be located between any building and any public street with
the exception of hotels, child care centers, and senior centers.
f. Drive-through service windows and drive-in facilities shall not be located between the principal structure and the
street.
2. Curb cuts:
a. Driveway and curb cut widths shall be 24 feet for two-way entrances and 12 feet for oneway entrances, unless otherwise
authorized by the Office of Public Works.
b. For the purposes of this section, two curb cuts serving two one-way driveways shall only be counted as one curb cut.
c. Except as authorized in subsection 16-18S.015(2)(b) of the Atlanta Zoning Ordinance, no more than one curb cut shall be permitted for each development, provided that properties with more than
one street frontage may have one curb cut located on each street frontage.
d. No curb cuts shall be permitted on arterial or collector streets when access can be provided from a local street.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.016. Off-street parking requirements
1. Parking requirements: The minimum number of parking spaces required, and maximum number allowed shall be in accordance with the following SPI-19 Vine City Parking Table. Any variation to increase the maximum allowable parking requirement shall be based upon criteria including, but not limited to the following:
a. Tenant demand based upon on-site uses;
and
b. Parking efficiency and utilization for onsite uses; and
c. Parking available off-site within onequarter-mile radius.
2. All parking areas and structures shall have delineated walkways at a minimum width of four feet, connecting parking to the required sidewalks and building entrances.
3. Parking between a building and a street:
a. Off-street surface parking shall not be located between a building and the street without an intervening building, with
the exception of; religious institutions with more than one street frontage shall not be permitted to have parking located between a building and a street without
an intervening building only on the street that fronts the defined front yard. For
religious institutions with more than one street frontage, side yards and rear yards with street frontages shall be permitted to have parking located between a building and a street without an intervening building.
4. Parking structures (either principal or accessory use): In addition to requirements contained in section 16-28.028 the following regulations shall apply:
a. Active uses shall occupy a minimum depth of 20 feet of the ground floor street frontage beginning at any building facade along the public sidewalk, except at
ingress and egress points. Such commercial uses located in this area shall meet the requirements of section
16-18S.012.
b. When located immediately adjacent to any public right-of-way, private street, public park, trail, or single-family
residential district:
i. Shall have an appearance of a horizontal storied building on all levels. Said structure shall have an appearance similar to or compatible with that of the adjoining or attached structure, including fenestration patterns and materials;
ii. May not have ramping that is visible from the public right-of-way, private street, public park, trail or
single-family residential district; and iii. Above-ground parking structures shall be designed so that the only openings at street level are those to accommodate vehicle entrances and pedestrian access to the structure.
Any openings for ventilation, service, or emergency access located on the first-floor level in the building facade shall be an integral part of the
overall building design or screened from view with landscaping at least 10 feet in height.
6. Office uses, additional requirements:
a. All office developments over 10,000 square feet shall reserve and designate, if parking is provided at least five percent of the-parking spaces "Carpool Only." Such
spaces shall be located near the building's entrance or other preferable locations
within the employee parking areas as approved by the commissioner of public works; and
b. All new parking structures shall be built to accommodate vanpool access at entry
level. The minimum ceiling height for vanpools is eight feet two inches.
7. Loading requirements: Minimum off-street spaces shall be provided in accordance with 16-28.015
Table 4: SPI-19 Vine City Parking Table Parking Spaces Minimum Maximum Residential Dwellings Hotels and motels (spaces per lodging unit) None 1.0 Residential Dwellings
• Per each one bedroom unit
• Per each two or morebedroom unit None 1.25 2.25 Non-residential Uses (Spaces per 1,000 sq. ft. of floor area)
Eating and drinking establishments None 2.5 Commercial/retail (not eating and drinking establishments) None 2.5 Institutional None 2.5 Office None 2.5 Recreation/Entertainment None 1.5 All Other Users None 2.0 (Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.017. Bicycle parking.
1. Minimum bicycle parking spaces shall be provided in accordance with 16-28.014(6).
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.018. Specific regulations for subarea 5, 6, and 7.
The following additional requirements apply to all uses located within Subareas 5, 6, and 7.
Please refer to the SPI-19: Development Controls Table and section 16-18S.015 driveway curb cuts, driveways and parking structures for additional requirements
1. Delineation of building floors at the third story above sidewalk level and lower
shall be articulated through windows, belt courses, cornice lines or similar architectural detailing.
2. Massing and articulation: Building facades greater than 100 continuous feet in
horizontal length shall include variety in facade treatment, materials, textures,
colors and/or window and door patterns and provide a depth change at a minimum of two feet to provide visual interest.
3. Roofs: All detached single family residential buildings shall have a gable, pitched, or hipped roof minimum roof
pitch of 4/12. Flat roofs for detached single family residential buildings are not allowed. Multi-family and mixed-use buildings with flat roofs shall be designed with a 3-foot minimum height parapet.
4. The primary pedestrian entrance for access to all sidewalk level uses and business establishments with public or private street frontage
a. Shall face and be visible from the public street when located adjacent to such street. When located adjacent to a street that functions as an arterial street or a collector street, said entrance shall face and be visible from such street.
5. A street address number shall be located directly above the primary building
entrance, shall be clearly visible from the sidewalk and shall be a minimum of six
inches in height.
6. Fenestration:
a. Street-fronting non-residential uses, with the exception of churches and
fire stations, along streets that function as arterial streets and collector streets shall meet the following
sidewalk level requirements:
i. The length of the facade without intervening fenestration or entryway shall not exceed 20 feet.
ii. Fenestration shall not utilize painted glass, reflective glass or other similarly treated or opaque windows. Entrances may be counted towards fenestration requirements.
iii. Fenestration shall be provided for a minimum of 65 percent of the length of all street frontages:
1. Beginning at a point not more than three feet above the sidewalk, or
2. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three or
more feet above the sidewalk; or
3. Beginning at a point not more than sidewalk level, to a height no less than ten feet above the finished floor elevation, when the finished floor elevation is below the sidewalk.
b. Fenestration shall be provided for a minimum of 25 percent of the length of the street frontage for residential uses on all streets and for nonresidential uses, with the exception of churches and fire stations, on all
streets other than streets that function as arterial streets and collector streets.
7. Buildings with residential uses at the sidewalk level, or park level shall meet the following regulations:
a. All primary pedestrian entrances not adjacent to a public sidewalk shall be linked to the public sidewalk with a pedestrian walkway a minimum of five feet wide.
b. All such buildings with more than four residential units that are adjacent to the sidewalk shall have individual entrances to such units directly accessible from the sidewalk and shall open directly onto the adjacent sidewalk, park, trail, plaza, terrace or porch adjacent to the sidewalk. All pedestrian walkways providing such access shall be perpendicular to the street, unless topography prohibits, and shall be permitted to share said walkway with one adjacent unit.
c. Such buildings shall have windows at sidewalk-level or park/trail level on each street frontage which are substantially similar in size to the sidewalk level front facade windows.
8. Siding and foundation:
a. A building's main/street facing facade should have a maximum of two
different cladding materials, excluding the fenestration material.
b. Single-family and two-family: All exterior facades shall be brick, wood, or Hardiplank, (cementitious siding).
Hardiplank siding shall be a maximum of six inches in width.
c. Multi-family, mixed use, and nonresidential:
i. All exterior facades adjacent to a public street, public park, and/or trail shall be brick, Hardiplank (cementitious siding) stone, cast stone, architectural
metal panels, or true stucco.
d. All exterior facades not adjacent to a public street shall be brick, stone, cast stone, true stucco, concrete masonry units, split-faced concrete, or split-faced block.
e. Single family and Two Family:
foundations shall be finished with brick, smooth stucco, or smooth finish concrete at least two feet above grade.
9. Front porches.
a. Front porches and/or stoops on the facade of the principal structure shall be required when such treatZONING §16-18S.018 ments are established by a majority
of the single-family detached dwellings on the block face.
b. Front porches, when required, shall:
i. Be a minimum of 12-feet wide or one-third the width of the front facade, whichever is greater, and a minimum of eight feet deep; and ii. Contain roofs, a minimum of six-inch wide porch roof supports, and steps.
c. For parcels with more than one street frontage, the front porch requirements of this section shall only be required to be applied to the building facade located in the front yard of the parcel, and not the half-depth front yard, side yard, or rear yard.
(Ord. No. 2020-14(19-O-1409), § 2(Att. A), 3-11- 20)
Sec. 16-18S.019. Affordable housing bonus.
1. Developments containing residential uses shall be permitted a floor area bonus of onetimes net lot area, provided that 20 percent of the total floor area developed shall be used for affordable for sale housing units or affordable rental housing for households earning 80 percent or less of the AMI. The percentage mix of affordable studio, one bedroom, two bedroom, and three-bedroom units shall be proportionally similar to the percentage mix in the overall development for market rate units.
2. Developments that provide ten percent affordable housing to households earning between 40 percent and 60 percent of AMI shall receive a bonus FAR of one times the net lot area plus two additional floors or 20 feet above the maximum height permitted without bonuses.
3. Developments that provide greater than 11 percent but equal to or less than 20 percent of affordable housing to households that earn between 40 percent and 60 percent of AMI shall receive an additional bonus:
a. Fronting Martin Luther King Jr. Drive Corridor.
i. 1.00 FAR bonus plus one bonus floor for each three percent of units offered above the ten percent affordable threshold up to 20 percent above the threshold.
1. Thirteen percent of units between 40 percent and 60 percent of AMI equals one floor bonus or ten feet above the maximum permitted height without bonuses.
2. Sixteen percent of units between forty percent and sixty percent of AMI equal equals two floor bonus or 20 feet above the maximum permitted height without bonuses.
3. Twenty percent of units equals three floor bonus height or 30 feet above the maximum permitted height without bonuses.
b. Fronting Vine Street between Martin Luther King Jr. Drive and Rhodes Street and fronting Sunset between Martin Luther King Jr. Drive and Magnolia Street.
i. 1.00 FAR bonus plus one bonus floor for each five percent of units offered above the ten percent affordable threshold up to 20 percent above the threshold.
1. Fifteen percent of units between 40 percent and 60 percent of AMI equals one floor bonus or ten feet above the maximum permitted height without bonuses.
2. Twenty percent equals two floor bonus height or 20 feet above the maximum permitted height without bonuses
3. Developments that provide between ten percent and 20 percent of the housing affordable for households that earn between 61 and 80 percent of
AMI shall receive bonus FAR and bonus height.
4. Developments that provide ten percent of the housing affordable to households that earn between 61 and 80 percent of
AMI shall receive an additional
1.0 FAR bonus plus two additional floors above maximum permitted building height before bonuses.
c. Fronting the Martin Luther King Jr. Drive Corridor.
i. Developments that provide between 11 percent and 20 percent of affordable units for households that earn between 61 percent and 80 percent
of AMI shall receive:
1.10 FAR for each one percentage increase between 11 percent and 20 percent of households earning between 61 percent and 80 percent of AMI.
2. One additional floor for each three percent of units offered between 11 percent and 20 percent of AMI.
a. Fourteen percent equals one floor or ten feet.
b. Seventeen percent equals two floors or 20 feet.
c. Twenty percent equals three floors or 30 feet.
d. Fronting Vine Street between Martin Luther King Jr. Drive and Rhodes Street and fronting Sunset between Martin Luther King Jr. Drive and Magnolia Street.
i. 1.00 FAR bonus plus one bonus floor for each five percent of units offered above the ten percent affordable threshold up to 20 percent above the threshold.
1. Fifteen percent of units between 61 percent and 80 percent of
AMI.
a.5 FAR bonus.
b. One floor height bonus or ten feet above the maximum permitted height without bonuses.
2. Twenty percent of units between 61 percent and 80 percent of AMI.
a. 1.00 FAR bonus.
b. Two floor bonus height or 20 feet above the maximum permitted height without bonuses.
4. Ground-floor commercial bonus: Developments which provide street-fronting, sidewalk level retail establishments or eating and drinking establishments which comprise a minimum of 20 percent of the building footprint and meet all of the requirements of subsection 16-18S.012(4) shall be permitted a residential floor area bonus for every one square foot of said space built, up to three additional square feet of buildings are permitted.
5. Civic bonus: Developments which provide recreational centers; community centers and community service facilities which are available to the general public during normal city recreational center, community center, or community service hours shall be permitted a residential floor area bonus equal to the total recreational center, community center or community service facility floor area. If such community use combined is 30 percent or more of the first floor the building shall receive a bonus height of one floor or 18-foot height increase.
6. High performance building bonus: Developments which are designed to meet established high performance, sustainability, resilience, low carbon, low energy, or healthy building standards or registered for LEED Silver or better, BREAM, EarthCraft, Energy Start, HERS Rating no greater than 47 or Enterprise Green Communities shall receive a .1 FAR density bonus. If a minimum of 20 percent of the housing is affordable to households earning less than 80 percent of AMI, the development will receive a .25 FAR bonus. Developments which are designed to meet Passive House (PHIUS), WELL, FitWell, LEED Gold, LEED Platinum, Net Zero, or Carbon Zero shall receive a .5 FAR density bonus. If 20 percent of the homes in the development are affordable to households earning less than 80 percent of the AMI, the development will receive a .70 FAR bonus.
(Ord. No. 2024-16 (23-O-1610), § 1, 4-24-24)
CHAPTER 18T. SPI-20 GREENBRIAR
SPECIAL PUBLIC INTEREST DISTRICT
REGULATIONS
Sec. 16-18T.001. Scope of provisions.
The regulations set forth in this chapter, or set forth elsewhere in this part when referred to in this chapter, are the regulations for the SPI-20 Greenbriar Special Public Interest District. These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in Section 16-18T.003, except that any existing categories of historic protection designated pursuant to Chapter 20 of Part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this Chapter.
Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. Whenever the following regulations conflict with provisions of Part 16 other than historic protection regulations, the more stringent regulation shall apply.
The regulations set forth in Sections 16-18T.001 through and including Section 16-18T.025 shall apply to all properties located within the SPI-20 Greenbriar Special Public Interest District, including all subareas within the District. The remaining regulations set forth in Section 16-18T.026 through Section 16-18P.031 shall apply only to the subareas identified therein.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.002. Statement of intent.
The intent of the council in establishing SPI-20 Greenbriar Special Public Interest District as a zoning district is as follows:
1. Implement provisions of the Comprehensive Development Plan incorporating certain recommendations contained in studies of this area, including the comprehensive study known as Greenbriar Town Center Livable Centers
Initiative Plan;
2. Create an urban environment where people can live, work, meet and play;
3. Improve the aesthetics of the built environment;
4. Encourage a compatible mixture of residential, commercial, cultural and recreational uses;
5. Provide a range of housing types and prices to meet different housing needs;
6. Provide appropriately-scaled, continuous pedestrian oriented uses and activities
adjacent to sidewalks along streets with identified pedestrian needs;
7. Facilitate safe, pleasant and convenient pedestrian circulation and minimize
conflict between pedestrians and vehicles;
8. Provide for development within this area that is compatible with existing lowdensity development within surrounding residential areas;
9. Prevent encroachment of incompatible commercial uses into residential neighborhoods;
10. Ensure pedestrian-oriented building forms;
11. Encourage infill and rehabilitation development within traditionally commercial areas that include proportionately significant residential uses;
12. Provide sufficient parking in an unobtrusive manner;
13. Encourage the use of transit through the location of mixed-use development and
regional entertainment and cultural facilities around a transit-oriented town center;
14. Encourage opportunities for economic development, both residential and commercial, where there is a planned relationship between the transportation system and development;
15. Maximize opportunities for pedestrian amenities, including parks, plazas, greenways and public art;
16. Provide sufficient, safe and accessible parks, plazas and greenways for active
and passive enjoyment; and
17. Reduce parking requirements by encouraging shared parking and alternative modes of transportation.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.003. Boundaries of district and subareas established.
The boundaries of the SPI-20 Greenbriar Special Public Interest District are shown on maps in Attachment B which by this reference is incorporated into and made a part of this chapter and this part. The Greenbriar Special Public Interest District is divided into six main subareas and other designated areas as shown on said map Attachment B. The subareas are described as follows:
Subarea 1: Greenbriar Town Center Subarea 2: Greenbriar Neighborhood Center Subarea 3: Campbellton Road Mixed Use Corridor Subarea 4: Greenbriar Residential/Commercial Subarea 5: Greenbriar Medium Density
Residential Subarea 6: Greenbriar Single-Family Residential (Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.004. Application procedures.
A special administrative permit shall be required for development in this district as set forth in this section. A special administrative permit (SAP) application and seven copies each of a site plan, landscape plan and elevation drawings of each exterior façade shall be submitted and approved by the director of the bureau of planning prior to the applicant filing for a building permit. All new construction, including additions to existing buildings, expansions of existing outdoor dining, outdoor dining within required sidewalk areas, or any construction which results in increased lot coverage or a modification of the building footprint within this district, shall be subject to said site plan review and approval.
Before making application for a special administrative permit, a pre-application conference between the applicant and the Director of the bureau of planning or the director's designee is required to discuss the application and relevant requirements of these regulations. Said preapplication conference shall be held within 14 days of the request by the applicant, unless a longer period is mutually agreed upon. All applications for a special administrative permit shall be processed in accordance with the standards and procedures applicable to said SAP applications contained in chapter 25 of part 16 except as otherwise modified by this chapter 18T.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.005. Permitted principal uses and structures.
A building or premises shall be used for the following permitted uses and structures:
1. See Table SPI-20 Greenbriar - Permitted uses for permitted principal uses, permitted accessory uses and structures, and special permits.
2. Permitted principal uses:
a. A building or premises shall be used only for the principal purposes as indicated with a "P" in SPI-20 Greenbriar - Permitted uses.
b. Uses indicated with a "P(X)" shall not exceed X square feet of floor area.
c. Commercial uses in Subareas 4 and 5 are further restricted as indicated in sections 16-18T.029 and 16-18T.030.
d. Battery exchange stations shall be permitted where service stations are permitted.
3. Special permits: The following uses are permissible only by special permits of the type indicated subject to limitations and requirements set herein or elsewhere in
this part, and subject to the applicable procedures and requirements set forth in section 16-25.001 et seq.
a. Special use permits shall be required as indicated with "SUP" in Table
SPI-20 Greenbriar - Permitted uses.
b. Special administrative permits shall be required as indicated with "SAP" in Table SPI-20 Greenbriar - Permitted uses.
c. Special exceptions shall be required as indicated with "SE" in table SPI-20 Greenbriar -Permitted uses.
All commercial sales and service shall be conducted within enclosed permanent
structures and there shall be no unenclosed displays of merchandise with the exception of outdoor dining. Outdoor sales or displays are permissible only by special permit as set forth below.
SPI-20 GREENBRIAR - PERMITTED USES
P = Permitted P(X) = Permitted, up to X square feet SE = Special Exception SAP = Special Administrative Permit SUP = Special Use Permit X = Not Permitted Subarea 1: Greenbriar Town Center Subarea 2: Greenbriar Neighborhood Center Subarea 3: Campbellton Rd Mixed-Use Corridor Subarea 4: Greenbriar Residential/Commercial Subarea 5: Greenbriar Medium Density Residential Subarea 6: Greenbriar Single-Family
Uses 1 2 3 4 5 6
RESIDENTIAL
Single-family dwellings P P P P P P Two-family dwellings P P P P P X Multi-family dwellings P P P P P X Assisted living facilities X X X SUP X X Dormitories1 X X X X X
Group homes2 X X X X X X Rooming houses X X X X X X Shelter SUP SUP SUP X X X Short-term rentals, subject to the regulations in Atlanta City Code section 20-1001.
P P P P P P
Single room occupancy residences X X X X X X Supportive housing X X X X X X
TRANSPORTATION & COMMUNICATIONS
Automobile service stations including locations where gasoline, oil, grease, batteries, tires, and automobile accessories may be supplied, sold, or dispensed at retail in connection
therewith or where general automotive servicing is performed
X X X X X X
Automotive repair garages, paint tire and body repair shops, auto parts retail stores, or carwashes (handwashing or automated)
X X X X X X
Broadcasting towers greater than 70feet in height3
SUP SUP SUP SUP SUP SUP
Broadcasting towers lower than 70 feet in height3
P P P P P P
Data centers, when located on subterranean levels or the second floor above sidewalk level and higher, or
on ground floors provided that retail, office, institutional, or residential uses are provided for a minimum depth of 20 feet from any building façade along the public sidewalk, and except where any part of the property is within 2,640 feet of a high capacity transit stop, as referenced in City Code Section 16- 28.014(14).
P P P X X X
Digital industry switchboards, power generators and other relay equipment and rooms housing such equipment when located on subterranean levels or the second floor above
sidewalk level and higher, or on ground floors provided that retail, office, institutional, or residential uses are provided for a minimum depth of 20 feet from any building façade along the public sidewalk.
Data centers are excluded from this use in this district.
P P P X X X
Helicopter landing facilities SUP SUP SUP X X X MARTA structures4 P P P P P P
SPI-20 GREENBRIAR - PERMITTED USES
P = Permitted P(X) = Permitted, up to X square feet SE = Special Exception SAP = Special Administrative Permit SUP = Special Use Permit X = Not Permitted Subarea 1: Greenbriar Town Center Subarea 2: Greenbriar Neighborhood Center Subarea 3: Campbellton Rd Mixed-Use Corridor Subarea 4: Greenbriar Residential/Commercial Subarea 5: Greenbriar Medium Density Residential Subarea 6: Greenbriar Single-Family
Uses 1 2 3 4 5 6 Park-for hire decks P P P SUP X X Park-for-hire surface lots SUP SUP SUP SUP X X Truck stops X X X X X X
RETAIL GOODS AND SERVICES
Any establishment offering check cashing services pursuant to a license issued pursuant to Article 4A of Title 7 of the Official Code of Georgia or that loans money to the public except for any state or federally chartered bank, trust company, credit union, savings and loan
association, or savings bank with deposits that are federally insured
X X X X X X
Automatic teller machines P P P P P X Bakeries and catering establishments P P P P(2,000) P(2,000) X Banks6 P P P P(8,000) X X
Barber shops, beauty shops, beauty supply, manicure shops and similar personal service establishments
X X X X X X
Convenience stores meaning a small retail establishment stocked to sell primarily prepackaged food items, but may also sell alcoholic beverages, periodicals, and other household supplies to customers who purchase relatively few items per visit.
X X X X X X
Drive-through service windows X X P7 X X X Dry cleaning collection stations P P P P(2,000) P(2,000) X Dry cleaning facilities P P P X X X
Grocery stores P P P P(15,000) X X Laundromats P P P P(2,000) P(2,000) X Package store as defined in Sec. 10-1 P18 X X X X X Photocopying or blueprint shops P P P P(2,000) X X Plumbing, air conditioning service
and repair
P P P X X X X
Retail establishments P P P P(8,000) X X Sales and repair establishments8 P P P P(4,000) P(4,000) X Small discount variety stores X X X X X X Tailoring and dressmaking P P P P(4,000) P(4,000) X
OTHER COMMERCIAL
Hotels SUP SUP SUP X X X Mortuaries and funeral homes SUP SUP SUP X X X New and used car sales X X X X X X
Nursing homes and convalescent centers
SUP SUP SUP X X X
ENTERTAINMENT
Adult businesses X X X X X X Bingo parlors SUP SUP SUP X X X Bowling alleys SUP SUP SUP X X X Eating and drinking establishments11
P P P P(8,000) P(4,000) X
Museums, art galleries, libraries9 P P P P(8,000) P(4,000) X Nightclubs X X X X X X
SPI-20 GREENBRIAR - PERMITTED USES
P = Permitted P(X) = Permitted, up to X square feet SE = Special Exception SAP = Special Administrative Permit SUP = Special Use Permit X = Not Permitted Subarea 1: Greenbriar Town Center Subarea 2: Greenbriar Neighborhood Center Subarea 3: Campbellton Rd Mixed-Use Corridor Subarea 4: Greenbriar Residential/Commercial Subarea 5: Greenbriar Medium Density Residential Subarea 6: Greenbriar Single-Family
Uses 1 2 3 4 5 6 Outdoor enterprises of thirty days duration or less10
SAP SAP SAP SAP X X
Outdoor enterprises of more than thirty days duration10
SUP SUP SUP SUP X X
Party houses provided that the use shall be prohibited within 150 feet of a property zoned R-1, R-2, R-2A,
R-2B, R-3, R-3A, R-4, R-4A, R-4B,
R-5, RG, MR or a property used for residential purposes measured from property line to property line
SAP SUP SAP SAP X X
Poolrooms and amusement arcades SUP SUP SUP X X X Theaters12 P P P X X X
OFFICES
Clinic13 P P P P(8,000) X X Offices, studios P P P P(8,000) P(4,000) X Professional or service establishments14
P P P X X X
CIVIC, EDUCATIONAL & RELIGIOUS
Business or commercial schools P P P X X X Childcare centers and kindergartens P P P P SUP X Churches, synagogues, [temples], and
mosques having a lot area greater than 1 acre
SUP SUP SUP SUP SUP SUP
Churches, synagogues [temples], and mosques having a lot area less than or equal to 1 acre
SE SE SE SE SE SE
Clubs and lodges P P P X X X Colleges and universities15 SUP SUP SUP X X X Community centers16 SUP SUP SUP X X X
Private schools P P P X X X Public schools P P P P P P
INDUSTRIAL
Commercial greenhouses X X SUP X X X Light manufacturing X X X X X X Security storage centers X X SUP X X X
OTHER
Farmers' market SAP SAP SAP SAP16 SAP16 SAP16 Hospitals SUP SUP SUP X X X
Market gardens P P P P17 P 17 P 17 Mortuaries, funeral homes, cemeteries, and mausoleums
X X X X X X
Urban gardens P P P SAP SAP SAP Notes:
1 including fraternity and sorority houses 2 including family care homes and congregate care homes 3 including line-of-sight relay devices for telephonic, radio or television communications 4 defined as: structures and uses required for operation of MARTA or a public utility but not including uses involving storage, train yards, warehousing, switching, or maintenance shops 5 including power generators and other telecommunications relay equipment 6 including savings and loan associations, and other similar institutions - but not including any drive-in service window 7 See Section 16-18T.028 for further restrictions in this Subarea.
8 for home appliances, bicycles, lawn mowers, shoes, clocks, or similar household goods 9 and similar profit or non-profit cultural facilities 10 defined as outdoor amusement enterprises, exhibits, entertainment, meetings, displays or sales areas, or outdoor religious ceremonies
11 including restaurants, bars, coffee shops, delicatessens and taverns 12 including other commercial recreation establishments with primary activities conducted within fully enclosed buildings 13 including veterinary (if animals are kept within soundproof buildings), laboratories, and similar uses, excluding blood donor stations
14 but not hiring halls 15 and other institutions of higher learning 16 farmers' market limited to parcels which meet the minimum lot size requirements and are used as churches, synagogues, temples, mosques and other religious worship facilities or schools 17 Market gardens are limited to parcels which are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
18 One wine specialty shop and one brewpub as defined in Section 10-1 is permitted in Subarea 1.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No. 2005-21, §§ 1, 2, 3-25-05; Ord. No. 2005-41(06-O0381), § 42, 7-12-05; Ord. No. 2008-62(06-O-0038), §§ 3O, 6Q, 7-7-08; Ord. No. 2009-24(08-O-1251), §§ 2V, 2V(2), 6-9-09; Ord. No. 2011-39(10-O-1773), § 3AA, 9-15-11; Ord. No. 2014-53(14-O-1278), § 2(Attach. B), 12-10-14; Ord. No. 2014-22(14-O-1092), § 2-FF, 6-11-14; Ord. No. 2019-20(18-O-1679), § 13, 3-13-19; Ord. No. 2019-26(19-O-1068), § 1, 5-15-19; Ord. No. 2019-66(19-O-1504), § 17, 12-11-19;
Ord. No. 2020-58(19-O-1393), § 44, 10-28-20; Ord. No. 2021-60(21-O-0682), § 40, 12-15-21; Ord. No.
2022-20(22-O-1017), § 1, 7-14-22; Ord. No. 2024-36(24-O-1222), § 8, 9-4-24) Sec. 16-18T.006. Permitted accessory uses and structures.
Accessory uses and structures permitted within this district shall include those customarily accessory and clearly incidental to permitted principal uses and structures and specifically includes clubhouses, pools, and other recreation amenities, parking to serve authorized residential and non-residential uses within the district subject to the restrictions contained elsewhere in this chapter, and electric vehicle charging stations equipped with Level 1, Level 2, and/or DC Fast Charge EVSE.
Accessory parking structures and lots for required parking are permitted within 300 feet of primary use as measured from the nearest property line, without a special exception.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2014-53(14-O-1278), § 2(Attach. B), 12-10-14) Sec. 16-18T.007. Special permits.
The following uses are permissible only by additional special permits of the type indicated subject to limitations and requirements set forth in this chapter 18T or elsewhere in this part, and subject to the applicable procedures and requirements set forth in section 16-25.001, et seq.
1. Special administrative permits:
a. Outdoor displays of merchandise or sales areas within the supplemental zone adjacent to commercial uses.
b. Off-site parking and shared parking within 1,000 feet of a primary use as measured from the nearest
property line.
c. Retaining walls greater than two feet in height between the building façade line and the street, where existing topography does not require retaining walls of a greater height, and except where necessary to meet the provisions in section 16-25.002(3).
d. Reduction of parking requirements may be permitted by the director of the bureau of planning subject to a shared parking arrangement under the following criteria:
i. The arrangement shall avoid conflicting parking demands and provide for safe pedestrian circulation and access;
ii. All shared parking spaces shall be clearly marked; and iii. An applicant shall submit the following information as part of the application to reduce parking requirements and avoid conflicting parking demands:
a. A to-scale map indicating location of proposed parking spaces;
b. Hours of business operation of nonresidential parking users;
c. Written consent of property owners agreeing to the shared parking arrangement;
d. Copies of parking leases.
renewed leases shall be filed with the bureau of planning. Lapse of a required lease agreement shall terminate the special administrative permit for shared parking.
e. Variations in width requirements for new streets when counted towards open space requirements when any of the following are provided:
i. Addition of bike lanes;
ii. Addition of angled parking;
iii. Addition of landscaped medians and roundabouts;
iv. Elimination of onstreet parking on one side of a one-way
street.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.008. Redevelopment requirements.
Subject to the provisions in Part 16, Chapter 24, Nonconformities.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.009. Transitional uses and
yards.
1. Adjoining lot with same frontage: Where a lot in this district abuts a lot in any R-1 through R-G, MR, RLC or PD-H district at the side along the same street frontage, and without an intervening street, such lot within this district, or the first 100 feet on such lot if it is wider than 100 feet, shall not be used for any drive-through service window or drive-in facility, car wash, service station, mortuary or funeral home, sales lot for automobiles, repair garage, or paint and body shop even where otherwise specifically authorized.
2. Transitional height planes:
a. No portion of any structure shall protrude through a height limiting plane beginning the specified number of feet above the point set forth in subsection
16-18T.009(2)(b) below and extending inward over the SPI-20 district at an angle of 45 degrees. The following districts shall be considered "protected districts" for purposes of this section 16-18T.009(2):
i. R-1 through R-5;
ii. RG-1 and RG-2;
iii. MR-1, MR-2, and MR-MU; and iv. Landmark, Historic, PD, and SPI districts and district subareas having uses and densities predominantly similar to those permitted in the district classifications listed in subsections (i) through (iii) above.
b. Proximity to districts and measurement applications:
i. For parcels in an SPI-20 district that are contiguous to a protected district, the transitional height plane shall be measured beginning 35 feet above the required SPI-20 setback or transitional yard adjoining the common property line with such protected district.
ii. For parcels in an SPI-20 district that are not contiguous to but are within 150 feet of a protected district, the transitional height plane shall
be measured beginning 15 feet above the nearest lot line of the protected district, provided this transitional height plane shall not extend more than 150 linear feet (measured along the ground) from the protected district up to and into the SPI-20 district. (See diagrams at section 16-29.001(62).)
c. The purpose and intent of this provision is to provide protection for the named
protected districts from nearby looming structures regardless of the presence of an intervening public right-of-way or park or space, public or private street or alley, or any lot or parcel remnant.
d. Transitional height plane measurements shall be applied to parcels on a point-bypoint basis and not average grade.
3. Transitional yards:
a. Where any subarea of this district adjoins an R-1 through R-5, R-G, MR, RLC or
PD-H district, or Subareas 5 or 6 within this district without an intervening street, a minimum of 20 feet is required which