Atlanta · Ordenanza de zonificación
Atlanta Zoning Ordinance
Este documento se muestra completo, como un solo texto: su fuente no lo divide en secciones.
Sobre este texto
- As published by Municode, current through 2026-10-21
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
- Read by OCR from a scanned page: a character, a name, or a number may be misread.
Este texto se leyó por OCR de una página escaneada: una letra, un nombre o un número pueden estar mal leídos.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Parte 9 de 24. Este texto es largo, así que su página lo muestra en partes, en el orden de la fuente. Un enlace a uno de sus párrafos lleva a la parte que lo contiene.
shall not be used for the purpose of parking, paving, loading, servicing or any other activity with the exception of private alleys or drives up to ten feet in width. Such yards shall be planted as
approved by the city arborist and maintained as a landscaped strip.
b. Screening: In addition to the above transitional yard requirements, permanent opaque walls six feet in height shall be provided and shall be maintained in sightly condition.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2019-09(18-O-1581), § 10.16, 1-31-19) Sec. 16-18T.010. Development controls.
See Table SPI-20 Greenbriar - Development controls and site limitations for bulk limitations, maximum building coverage, public space requirements, minimum open space requirements, and maximum height.
For purposes of this chapter, and notwithstanding the provisions of Code section 16-29.001(24), mixed-use development is defined as any development which contains as principal uses both residential and non-residential uses on the same development site, and in which both of such uses are at least 20 percent of the total floor area, excluding accessory uses.
1. Bulk limitations:
a. Maximum permitted floor areas without bonuses:
i. For nonresidential uses, the ratio of floor area to lot area shall not exceed the amount indicated under "Maximum Nonresidential FAR" in Table SPI-20 Greenbriar - Development controls and site limitations for each subarea (See section 16-18T.010(2)).
ii. For residential uses, the ratio of floor area to net lot area shall not exceed the amount indicated under "Maximum Residential FAR" in Table SPI-20 Greenbriar - Development controls and site limitations for each subarea.
iii. For developments that combine residential and non-residential uses, the ratio of floor area to net lot area shall not exceed the sum of the amounts indicated under "Maximum Residential FAR" and "Maximum Nonresidential FAR" in Table SPI-20 Greenbriar - Development controls and site limitations for each subarea, but not greater than the maximum floor areas permitted for each (See section 16-29.001(24).
b. Maximum permitted floor area with bonuses: Under no circumstances shall the ratio of floor area to gross lot area of any development with bonuses exceed the amount indicated under "Maximum Combined FAR With Bonuses" indicated in Table SPI-20 Greenbriar - Development controls and site limitations for each subarea.
2. Residential uses may use net lot area or gross lot area when calculating maximum permitted residential floor area, provided that usable open space requirements (UOSR) are calculated based on the same lot area.
Table SPI-20 Greenbriar - Development Controls and Site Limitations Subarea 1: Greenbriar Town Center
Subarea 2: Greenbriar Neighborhood Center Subarea 3: Campbellton Rd Mixed-Use Corridor Subarea 4: Greenbriar Residential/Commercial Subarea 5: Greenbriar Medium Density
Residential Subarea 6: Greenbriar Single-Family 1 2 3 4 5 6 Nonresidential FAR (base) or Maximum
Percentage of Development
2.5 1.5 1.0 20% 5% None Residential FAR (base) 0.696 0.696 0.696 2.0 0.696 0.5 Combined Maximum FAR without bonuses 3.196 2.196 1.696 2.0 0.696 0.5 Additional Open Space Bonus YES YES YES YES NO NO Ground Floor Commercial Bonus YES YES YES YES NO NO Civic Space Bonus YES YES YES YES NO NO
New Streets Incentive YES YES YES YES YES YES On-street Parking Incentive YES YES YES YES YES NO Combined Maximum FAR with bonuses 3.696 2.696 2.0 2.696 0.696 0.5 Maximum Building Coverage (percent of net lot area)
85% 85% 85% 85% 85% 50% Residential Usable Open Space Requirement
(UOSR)
LUI LUI LUI LUI LUI LUI
Non-residential Public Space Requirement, as a % or net lot area
10% 10% 10% 10% None None Minimum Lot Size None None None 2,000 sf/None* 2,000 sf/None* 3,000 sf Minimum Street Frontage None None None 40'/25'** 40'/25'** 40' Minimum Façade Height 24' 24' 24' None None None Maximum Height 80
feet 52 feet 52 feet 80 feet 52 feet 35 feet *Minimum lot size is none for townhouse development, 2,000 square feet otherwise.
**Minimum street frontage is 25' for townhouse development, 40' otherwise.
3. Minimum open space requirements: When either the residential or non-residential component of the development is a minor
use of less than 20 percent of the total floor area minimum open space requirements do not apply to such minor use.
a. For residential uses, including all residential components of mixeduse developments: Open space requirements as indicated on Table
I, "Land Use Intensity Ratios" shall be required for useable open space (UOSR) only.
b. For non-residential uses, including all non-residential components of mixed-use developments: Public space requirements shall be as indicated in Table SPI-20 Greenbriar
- Development controls and site limitations. (See Section 16-28.012 for definitions and measurements.
Required yards and requirements for sidewalk and supplemental zone widths that are constructed on private property may be counted towards this requirement. Such public space may include planted areas, fountains, community gardens, parks plazas, hardscape elements related to sidewalks and plazas, and similar features which are located on private property.)
c. For mixed-uses: The sum of minimum open space requirements specified in subsections a. and b.
above for non-residential and residential shall be met.
4. Residential balconies: Balconies for residential units, which are enclosed on not more than three sides, may be counted towards UOSR for a maximum depth of
six feet.
5. Additional open space bonus: If indicated for a subarea in Table SPI-20 Greenbriar
- Development controls and site limitations, developments in that subarea shall be permitted a residential bonus of two
square feet of residential floor area for each one square foot of open space
provided above the minimum required herein. Said bonus shall be permitted provided that open space:
a. Shall provide active or passive recreational amenities;
b. Shall be no greater than 24 inches above or below the adjacent public sidewalk for a minimum distance of 15 feet from the beginning of the adjacent sidewalk;
c. Shall be visible and accessible from any point along 90 percent of any adjacent sidewalk; and
d. Shall permit and encourage pedestrians to walk on a minimum of 80 percent of the surface of the parcel excluding fountains, pedestrian furniture, public art and similar elements.
6. Ground-floor commercial bonus: If indicated for a subarea in Table SPI-20 Greenbriar - Development controls and site limitations, developments that provide street-fronting, sidewalk level retail
establishments or eating and drinking establishments that comprise a minimum of 20 percent of the building foot print and meet all of the requirements of section 16-18T.015(1) shall be permitted a residential floor area bonus of three
additional square feet for every one square foot of said space built.
7. Civic space bonus: If indicated for a subarea in Table SPI-20 Greenbriar -
Development controls and site limitations, developments which provide recreational centers, community centers
and community service facilities which are available to the general public during normal city recreational center, community center or community service hours shall be permitted a residential floor
area bonus of one square foot for every one square foot of said space built.
8. New streets incentive: New public streets, or private streets which function as public streets may be counted towards UOSR
and public space requirements provided the following criteria are met:
a. The new streets connect two other public streets or private streets;
and
b. The new streets meets the requirements of Section 16-18T.012; and
c. The maximum width of said streets shall be 38 feet; and
d. The new streets shall include two on-street parallel parking lanes, two travel lanes and sidewalk extensions at intersections; and
e. When adjacent to a park area, new streets shall meet all above requirements along each park edge.
f. Gates shall not be permitted across said streets.
9. On-street parking incentive: New onstreet parking may be counted towards UOSR or public space requirements
provided the following criteria are met:
a. No on-street parking currently exists in the public right-of-way adjacent
to the project area for which credit is sought; and
b. The new on-street parking is located where there is no existing street lane; and
c. Sidewalk extensions are provided at street intersections where appropriate; and
d. All other sidewalk requirements of this Chapter are met.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.011. Site limitations.
1. Minimum building façade heights: Buildings shall have a minimum façade height along each façade adjacent to any sidewalk or
supplemental zone as shown in Table SPI-20 Greenbriar - Development controls and site limitations.
2. Maximum building heights: In addition to the requirements of transitional height planes specified in section 16-18T.009(2), buildings shall have a maximum height as shown in Table
SPI-20 Greenbriar - Development controls and site limitations.
3. New development or redevelopment proposing to contain an entire block face greater than 600 feet in length shall be traversed by streets which create block faces no more than 400 feet in length, except when topographical conditions prevent the introduction of new streets as required, or to allow new streets to coincide with an existing street grid. For the purposes of this chapter, a block face shall be measured from the back of sidewalk clear zones or required supplemental zones. Such streets shall function as public streets and shall connect two other public streets or private streets that meet the requirements of section 16-18T.010(8).
4. Requirement for continuation of existing street network: Properties adjacent to the rightof-way of existing public streets which dead-end or cul-de-sac shall provide a street connection to the existing right-of-way and shall meet the requirements of section 16-18T.010(8) and section 16-18T.012, unless existing site topography does not permit such a connection to be made as determined by the commissioner of the department of transportation, or his/her designee.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2020-33(20-O-1381), § 36, 6-23-20) Sec. 16-18T.012. Sidewalks.
Public sidewalks shall be located along all public streets and all private streets that function as public streets and shall have minimum widths as specified herein. Sidewalks shall consist of two zones:
a street furniture and tree planting zone, and a clear zone.
Table SPI-20 Greenbriar - Development Controls and Site Limitations Subarea 1: Greenbriar Town Center
Subarea 2: Greenbriar Neighborhood Center Subarea 3: Campbellton Rd Mixed-Use Corridor Subarea 4: Greenbriar Residential/Commercial Subarea 5: Greenbriar Medium Density
Residential Subarea 6: Greenbriar Single-family 1 2 3 4 5 6 Minimum Street Furniture and Tree Planting Zone Width
5' 5' 5' 5' 5' 5' Minimum Clear Zone Width 10' 10' 10' 10' 6' 6' Minimum Supplemental Zone Width 5' or None* 5' or None* 5' or None* 9' or 5'** 9' or 5'** None Minimum Side Yard - not adjacent to street 20' or Noneˆ
20' or Noneˆ 20' or Noneˆ 15' or Noneˆ 15'/5'or Noneˆˆ 5' Minimum Side Yard - adjacent to street see supplemental zone
see supplemental zone see supplemental zone see supplemental zone see supplemental zone 10' Minimum Rear Yard 20' or Noneˆ 20' or Noneˆ 20' or Noneˆ 20' 15' 15' Minimum Front Yard Setback see supplemental zone
see supplemental zone see supplemental zone see supplemental zone see supplemental zone 20' *Minimum supplemental zone width is 5' on streets that function as arterial and collector streets, none otherwise.
**Minimum supplemental zone width is 9' on streets that function as arterial and collector streets, 5' otherwise.
ˆNonresidential uses: None. Residential use: Setback may be reduced to zero when no residential windows are adjacent to such yard.
ˆˆNonresidential uses: None. Multi-family residential use: 15' setback may be reduced to zero when no residential windows are adjacent to such yard. Single-family residential uses: 5'.
The following regulations shall apply to all public sidewalks:
1. Street furniture and tree planting zone requirements: The street furniture and
tree planting zone shall have a minimum width as specified in SPI-20 Greenbriar - Sidewalk and setback requirements. Said
zone shall be located immediately adjacent to the curb and shall be continuous. Said zone shall meet the tree planting requirements of section 16-18T.012(3). In addition to the required planting of trees, this zone may also be used for the placement
of street furniture including utility poles, waste receptacles, fire hydrants, traffic signs, newspaper vending boxes, bus
shelters, bicycle racks and similar elements in a manner that does not obstruct pedestrian access or motorist visibility and as approved by the director of the
bureau of planning.
2. Clear zone requirements: The clear zone shall be a minimum width as specified in SPI-20 Greenbriar - Sidewalk and setback requirements. Said zone shall be located immediately contiguous to the street
furniture and tree planting zone and shall be continuous. Said zone shall be hardscape, and shall be unobstructed for a minimum height of eight feet except as authorized in section 16-18T.014(7).
3. Street tree planting requirements: Street trees are required and shall be planted in the ground a maximum of 50 feet on
center within the street furniture and tree planting zone and spaced equal distance between streetlights. All newly planted trees shall be a minimum of two
and one-half inches in caliper measured six inches above ground, shall be a minimum of 12 feet in height, shall have a minimum mature height of 40 feet, and
shall be limbed up to a minimum height of seven feet. Trees shall have a minimum planting area of 40 square feet. All plantings, planting replacement and planting removal shall be approved by the city
arborist. The area between required plantings shall either be planted with evergreen ground cover such as mondo grass or
liriope spicata or shall be paved as approved by the director of planning.
4. Tree grates: Tree grates are not required where all sidewalk width requirements
are met. Where tree grates are required or otherwise installed, they shall be a minimum of five feet by eight feet, shall be a type specified by the director of
planning in accordance with uniform design standards utilized by the director for placement of such objects in the public right-of-way, and shall be placed within the street furniture and tree planting
zone. Where tree grates are not required or otherwise installed, tree planting areas shall be permitted to be planted with
evergreen ground cover such as mondo grass or liriope spicata.
5. Paving: All paving within the street furniture and tree planting zone shall be a type specified by the director of planning in accordance with uniform design standards utilized by the director for
placement of such objects in the public right-of-way.
6. Nothing shall be erected, placed, planted or allowed to grow in such a manner as to impede visibility within visibility triangles at street intersections between the heights of two and one-half feet and eight feet
above grade. See section 16-28.008(9), Visibility at intersections.
7. No awning or canopy shall encroach beyond the clear zone. Metal awnings are prohibited.
8. Where property within this district abuts an R, R-G, MR, PD-H, or LW district
without an intervening street, the sidewalk area within twenty (20) feet of such districts shall taper as necessary to provide a smooth transition to the existing R, R-G, MR, PD-H, or LW districts sidewalk. In the event that the abutting R, R-G, MR, PD-H or LW district has no
existing sidewalk, the sidewalk shall taper to a width of six feet.
9. Decorative pedestrian lights, where installed, shall be placed a maximum of 50 feet on center and spaced equal distance between required trees along all streets.
Where installed, said lights shall be located within either the street furniture and tree planting zone or the
supplemental zone. All said lights shall be Atlanta Type "C" as approved by the
planning bureau.
10. Every commercially reasonable effort shall be made to place utilities underground or to the rear of structures to allow for
unobstructed use of sidewalks.
11. Trash receptacles or similar elements, where installed, shall be a type specified by the Director of Planning in accordance with uniform design standards utilized
by the Director for placement of such objects in the public right-of-way and shall be placed within the street furniture and tree planting zone.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), § 2, 7-14-22) Sec. 16-18T.013. Supplemental zone.
For purposes of these regulations, the area between any building, parking garage, or parking lot and the required sidewalk, when no intervening building exists, shall be defined as the supplemental zone. Supplemental zones shall meet the following requirements. Except as otherwise specified below, the square footage contained within a supplemental zone which meets all the following supplemental zone requirements may be counted towards UOSR or public space requirements.
1. Supplemental zone general requirements:
a. When sidewalk level residential units are provided, supplemental zone
shall be landscaped with the exception of terraces, porches, stoops and walkways, which may occupy a
maximum of two-thirds of the supplemental zone area;
b. Terraces, porches and stoops shall have a maximum finished floor height of 24 inches above finishedgrade, unless existing topographical considerations render this requirement unreasonable, subject
to the provisions in section 16-25.002(3);
c. The supplemental zone shall be no more than 24 inches above the adjacent public sidewalk for a minimum linear distance of 15 feet from the nearest edge of the adjacent public sidewalk, unless existing topographical considerations render this requirement unreasonable; and
d. Any authorized walls surrounding landscaped and grassed areas shall not exceed a maximum height of 24 inches, except retaining walls, which shall not exceed a maximum height of 36 inches unless existing topography requires a retaining wall of greater height.
e. Fencing permitted only when:
i. The supplemental zone is located between sidewalk level residential units and the adjacent street; or ii. Said fencing is used to separate authorized outdoor dining from the required sidewalk.
2. Supplemental zone widths: Along front and side façades shall be a minimum
width as specified in SPI-20 Greenbriar - Sidewalk and setback requirements.
3. Supplemental zones containing a depth of 15 feet or less shall meet the following additional requirements:
a. No balcony shall encroach more than ten feet into the supplemental zone area.
b. Shall not be counted towards UOSR or public space requirements unless visible and accessible to the general public from the adjacent public sidewalk, with the exception of areas adjacent to sidewalk level residential units.
4. Supplemental zones containing a depth greater than 15 feet shall be counted
towards UOSR or public space requirements only when the following additional requirements are met:
a. Shall permit and encourage pedestrians to walk on a minimum of eighty (80) percent of the surface of the supplemental zone excluding fountains, pedestrian furniture, public art and similar elements.
b. When adjacent non-residential ground floor uses are provided, shall be visible and accessible from any point along 90 percent of any adjacent sidewalk.
c. When adjacent non-residential ground floor uses are provided, all sides of buildings fronting said zone meet the requirements of section 16-18T.015(1).
d. When adjacent residential ground floor uses are provided, shall provide a pedestrian walkway from said space to the adjacent public sidewalk.
Said pedestrian walkway shall be perpendicular to the street and shall connect directly to the public sidewalk and shall be uncovered and open to the sky along its entire length.
5. Developments of greater than one acre in area and adjacent to existing transit
stops which have no shelters shall provide a shelter within the supplemental zone
for a minimum of one such stop. The design and location of such stop shall be approved by the director of the bureau of planning.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.014. Relationship of building to street.
1. For purposes of this chapter, sidewalk-level shall be defined as any floor of a building with a finished-floor elevation less than or equal to five feet above the adjacent sidewalk or less than or equal to five feet below the adjacent sidewalk.
2. Building floors shall be delineated at third story above sidewalk level and lower and shall be executed through windows, belt courses, cornice lines or similar architectural detailing.
3. The primary pedestrian entrance for pedestrians to access all sidewalk level uses and business establishments with street frontage:
a. Shall face and be visible from the street.
When located adjacent to a Storefront Street, said entrance shall face and be visible from such street.
b. Shall be directly accessible and visible from the sidewalk.
c. Shall remain unlocked during business hours for non-residential uses.
d. Shall be connected with the sidewalk by a pedestrian pathway that is
perpendicular to the sidewalk and is a minimum of four feet in width.
e. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five
foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit.
This provision shall not apply to singlefamily and two-family residential structures.
4. A street address number shall be located directly above the primary building entrance, shall be clearly visible from the sidewalk and shall be a minimum of six inches in height.
5. Buildings with residential uses at the sidewalk level shall meet the following regulations:
a. All primary pedestrian entrances not adjacent to a public sidewalk shall be linked to the public sidewalk with a pedestrian walkway a minimum of five feet wide for commercial, mixed-use, and multi-family residential development
(excluding townhouse development), and three feet wide for townhouse, singlefamily, and two-family development. Said pedestrian walkway shall be perpendicular to the street and shall be permitted to
share said walkway with one adjacent unit.
b. Buildings shall have windows at sidewalk level on each street frontage façade that are substantially similar in size to the sidewalk level front façade windows.
6. Along all streets, parking, storage or digital industry switchboards, power generators and other relay equipment and rooms housing such equipment shall be permitted, with the exception that such uses shall not occupy a minimum depth of 20 feet of the ground floor street frontage beginning at any building façade along the public sidewalk. Said buildings shall meet the following additional requirements:
a. Shall meet the requirements of section 16-18T.015(1) except at ingress and egress points into the structure and when
topographical conditions prevent such treatment; or
b. Shall meet the requirements of section 16-18T.014(5) except at ingress and egress points into the structure and when
topographical conditions prevent such treatment.
7. Sidewalk arcades: Buildings with nonresidential uses at the sidewalk level may have sidewalk arcades, which shall meet the following regulations:
a. Shall provide an at grade sidewalk surface.
b. Arcade supports shall be a maximum width of five feet.
c. Shall provide a minimum of 25 feet of clear unobstructed space between arcade
supports.
d. A building with a sidewalk arcade shall meet the requirements of section
16-18T.015.
e. Shall provide a minimum clear zone width of 15 feet and when located on streets
which function as arterial streets or Storefront streets, shall provide a minimum supplemental zone width of five feet.
8. Fences and walls shall meet the following regulations:
a. For residential uses adjacent to the sidewalk, fences shall not exceed 42 inches in height when located between the
primary building and the street or between any supplemental zone and the adjacent
street. For non-residential uses adjacent to the sidewalk, fences are prohibited
when located between the building and the sidewalk except where specifically authorized elsewhere in this Chapter for outdoor dining.
b. Retaining walls located adjacent to a sidewalk along a public street shall not exceed a height of two feet and the
combined height of a fence where otherwise authorized and retaining wall shall not exceed a height of five feet, unless existing topography prohibits retaining walls of a lesser height. Retaining walls shall be finished poured concrete or shall be faced with stone, brick or
smooth stucco. See also section 16-29.001(25)(b).
c. No walls, except retaining walls, shall be located between the street and any building, with the exception of screening for authorized off-street loading areas.
d. Fences and walls located between the primary building and the lot line and not exceeding six feet in height may be
erected, but shall not be permitted between the primary building and the street.
e. Where wood fences are constructed the finished side shall be toward all property lines that front the public right of way or property zoned R-1 through R-5, MR,
PD-H or used for residential purposes.
f. Wood fencing other than cedar or redwood must be stained or painted.
g. Fencing shall have a horizontal top and bottom trim. Bright or fluorescent colors are prohibited.
h. Chain link fencing shall be black or dark green vinyl coated.
9. No barbed wire, razor wire, chain link fence or similar elements shall be visible from any public plaza, ground level or sidewalk level outdoor dining area or public right-of-way.
10. Vending machines, paper stands, and other similar devices shall be located interior to all buildings.
11. On non-residential structures shingled slanted roof lines are prohibited. Metal roofs are permitted. Exposed gutters are prohibited for use with flat roofs. All flat roofs shall have a parapet and cornice and shall be continuous on all building elevations.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), §§ 3, 4, 7-14-22; Ord. No.
2026-05(26-O-1001), § 12, 2-25-26) Sec. 16-18T.015. Specific regulations for storefront streets.
Properties which front streets indicated in Exhibit B as Storefront Streets shall meet the following regulations:
1. Street-fronting buildings including parking decks shall meet the following sidewalk level requirements:
a. The length of façade without intervening fenestration or entryway shall not exceed 20 feet.
b. For buildings with ground floor commercial uses, fenestration shall be provided for a minimum of 65 percent
of the length of the frontage. For buildings with ground floor residential uses, fenestration shall be provided for a minimum of 51 percent of the length of the frontage excluding gables, windows, doors, and related trim.
i. Beginning at a point not more than three feet above the sidewalk, to a height no less than ten feet above the sidewalk or, ii. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three or more feet above the sidewalk or iii. Beginning at a point not more than sidewalk level, to a height no less than ten (10) feet above the finished floor elevation when the finished floor elevation is below the sidewalk.
c. Fenestration shall not utilize painted glass, reflective glass or other
similarly treated or opaque windows.
Entrances may be counted towards fenestration requirements.
d. For parking decks, commercial uses shall occupy a minimum depth of 20 feet of the ground floor street frontage beginning at any building façade along the public sidewalk, except at
ingress and egress points. Such commercial uses located in this area shall meet the requirements of section 16-18T.015.
2. Minimum building façade height: Twentyfour feet along each façade visible from the public right-of-way.
3. Horizontal change of materials. A horizontal change of materials from one material to another shall include a cast stone cap or masonry sill. The cap sill
shall project from the face of the building.
4. Building entrances. The primary pedestrian entrance facing the street and sidewalk shall be articulated and difZONING § 16-18T.015 ferentiated from other components of the façade with two or more of the following elements: Transom windows; awnings or
canopies.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), §§ 5, 6, 7-14-22) Sec. 16-18T.016. Signage.
Refer to section 16-28A, Sign Ordinance.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.017. Loading areas, loading
dock entrances and building mechanical and accessory features.
1. Dumpsters and loading areas:
a. Shall be paved with impervious materials and shall be screened so as not to be visible from any public plaza, ground
level or sidewalk level outdoor dining area, public sidewalk or public right-of way.
b. When serving residential uses, shall be enclosed with opaque walls six (6) feet in height.
c. When serving non-residential uses and located within three hundred (300) feet
of single-family residential uses, shall be located immediately adjacent to the side or rear of the principal structure or shall be in the location of least sound and
visual impact to nearby single-family residential uses.
d. Dumpsters shall be screened with brick opaque walls and a self-closing opaque
gates along one side which matches the brick color. Gate material shall be wood, metal or vinyl. Screening shall be 12
inches above the dumpster at a maximum height of seven feet.
2. Loading dock entrances for non-residential uses shall be screened so that loading docks and related activity are not visible from the public right-of-way.
3. Building mechanical and accessory features:
a. Shall be located to the side or rear of the principal structure and shall be in the
location of least visibility from the public right-of-way. Screening with plant or fence materials shall be required if the equipment is otherwise visible from the public right-of-way.
b. When located on rooftops shall be incorporated in the design of the building and screened with building materials
similar to the building.
c. Shall not be permitted between the building and any public street.
d. Building mechanical and accessory features not located on rooftops shall provide landscaping. Shrubbery shall consist of a continuous hedge of evergreen shrubbery and shall be a minimum height
of three feet at the time of planting and reach a minimum height of six feet at
maturity.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), § 8, 7-14-22) Sec. 16-18T.018. Off-street loading requirements.
See Table of Loading Requirements, Section 16-28.015 Off-street Loading Requirements.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.019. Curb cuts and parking
structures.
1. All sidewalk paving materials shall be continued across any intervening driveway at the same prevailing grade and cross slope as on the adjacent sidewalk clear zone.
2. For mixed-use, commercial, and multifamily residential development (excluding townhouses), driveways shall have a band of textured concrete adjacent to the street that is in-line with and equal in width to the street furniture zone and shall have a textured band of concrete adjacent to the sidewalk which is in-line with the supplemental zone and a minimum width of five feet from the sidewalk.
3. Driveway and curb cut widths shall be a maximum of 24 feet for two-way entrances and 12 feet for one-way entrances, unless otherwise permitted by the commissioner of transportation.
4. No circular drives shall be located between any building and any public street with the exception of hotels, childcare facilities, kindergartens, and special schools.
5. Curb cuts and driveways shall not be permitted on any street that functions as an arterial street or collector street when access may be provided from a side or rear street located immediately adjacent to a contiguous property, with the exception of hotel patron drop-off drives.
6. Unless authorized by section 16-18T.019(4), driveways, except for a driveway to reach the side yard or rear yard or an on-site parking facility, are not permitted between the sidewalk and a building, and shall be perpendicular to any adjacent street.
7. No more than one curb cut shall be permitted for each development, provided that properties with more than one street frontage may have one curb cut located on each street frontage.
8. Entrances to garages and carports that serve a single residential unit shall face the rear yard or a side yard that has no street frontage, or shall have a front yard setback of at least 50 percent of the property depth.
9. All contiguous ground-floor residential units shall share one common drive, located in rear yards or side yards without street frontage, to serve garages, carports and parking areas.
10. Parking deck façades shall conceal automobiles from visibility from any public rightof-way or private drive or street that are open to the general public, and shall have the appearance of a horizontal storied building.
11. Notwithstanding the provisions of section 16-28.006(10), a common or joint driveway may be authorized by the director of the bureau of planning when adjacent lots have direct vehicular access to a street, and a driveway from a private street which functions as a public street may be authorized by the director of the bureau of planning, based on traffic considerations, when a perpetual easement agreement is agreed upon by all affected property owners and a copy of such agreement is provided to the bureau of planning.
12. All developments, including parking decks, shall have sidewalks a minimum width of four feet connecting ground level parking to the public sidewalks and to all building entrances.
See section 16-18T.021, Minimum landscaping for parking lots, barrier requirements.
13. No drop-off lanes shall be permitted along public streets.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2020-33(20-O-1381), § 37, 6-23-20) Sec. 16-18T.020. Lighting, security, and maintenance requirements.
1. All lighting including all parking decks and lots and lit canopies shall reduce light spillage onto residentially used properties by providing cutoff luminaries that have a maximum 90-degree illumination.
2. All lighting that up-lights trees, buildings or other elements, shall be located a minimum height of eight feet above the sidewalk, driveway or pedestrian area when not located within completely landscaped areas.
3. All surface parking lots and structures, whether a nonconforming principal use or accessory use, and whether commercial or noncommercial, shall have the following minimum requirements:
a. Lighting shall be provided throughout all parking facilities to equal a minimum of two footcandles of light. A footcandle of light is a uniformly distributed flux of one lumen on a surface of one square foot in area. Where applicable, public street lighting may be utilized to either partially or totally fulfill the lighting requirements; however, where such street lighting is removed, it shall be the responsibility of the parking facility to independently provide these required
levels of illumination.
b. Parking facilities shall be maintained in a clean, safe and sanitary condition. Parking spaces and driving lanes shall be clearly defined and maintained as such.
Parking lots shall not be operated when any damage impairs the drivability of the parking lot. See Section 16-28.014 for additional requirements.
c. Parking facilities operating before the effective date of this section shall have 24 months to comply herewith.
4. Burglar bars, street gates, and steel roll down doors or shutters are prohibited on the exterior of a structure when visible from any public or private street. Interior security burglar bars, steel gates and roll down doors shall allow 80 percent visibility into the tenant space and shall be fully retractable during business operational hours.
5. Vacant buildings or storefronts shall not have burglar bars, street gates, and steel roll down doors or shutters visible from a public or private street 30 days from the passage of this Ordinance.
6. Lights outlining, or detailing buildings or windows are prohibited.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), § 9, 7-14-22) Sec. 16-18T.021. Minimum landscaping for surface parking lots, barrier requirements.
The requirements of City of Atlanta Code of Ordinances, Chapter 158 Vegetation, Article II Tree Protection, Section 30 Parking Lot Requirements shall apply to this district except as modified as follows:
1. Said parking lot requirements shall apply to all lots regardless of size;
2. All parking bays shall be terminated with a landscaped strip a minimum width of five feet and equal to the length of the parking bay.
3. All required landscaped areas shall be planted with evergreen groundcover or
shrubs with a maximum mature height of 30 inches.
4. All required landscaped buffer areas and strips, regardless of length, shall have a minimum of one tree with a minimum
caliper of two and one-half inches.
5. Parking lot landscaping.
A. Applicability. Parking lot landscaping is required on all on-site surface parking lots created after the effective date of this chapter. Multiple platted lots contained on a single
site plan and any separate parking areas connected with drive aisles are considered a single parking area.
B. Perimeter screening. All surface parking areas as well as drive aisles and other related vehicular use areas
must be screened from view from the adjacent street using one of the options below. A required landscape strip must be located at the outer perimeter of the parking area and must be provided along the entire parking area, excluding breaks for pedestrians, bicycles, and driveways.
For screening options that include shrubs, those must be 30 inches tall at the time of planting and 70 percent of them must be evergreen.
1. Landscape strip with shrubs.
A minimum ten-foot-wide landscape strip planted with shrubs. Shrubs must be provided to fully screen paved areas and parking lots from the right-of-way within three years of planting.
2. Landscape strip with screening wall. A 2.5-foot-high screening wall located within a minimum four-foot planting
strip. Screening walls must be closed and be constructed of high-quality materials including one or a combination of the following: decorative blocks;
brick; stone; cast-stone; stucco over standard concrete masonry blocks; glass block; or other material approved by the director of the office of zoning and development.
3. Landscape strip with berm. An earth berm a minimum of 2.5 feet higher than the finished elevation of the parking area, planted with five shrubs for every 35 linear feet of street frontage, excluding driveway openings. The berm must contain a rounded crown suitable for planting, and a stabilized side slope of no
greater than 3:1.
4. Landscape strip with grade change. A six-foot landscaped strip with a minimum threefoot grade drop from the street to the parking area, planted
with five shrubs for every 35 linear feet of street frontage, excluding driveway openings.
C. Interior islands.
1. A landscaped interior island must be provided every eight parking spaces. Interior islands must be distributed evenly throughout the parking area.
Interior islands may be consolidated or intervals may be expanded in order to preserve existing trees.
2. An interior island abutting a single row of parking spaces must be a minimum of nine feet in width and 200 square feet in area. Each island must include one shade tree.
3. An interior island abutting a double row of parking spaces must be a minimum of nine feet in width and 400 square feet in area. Each island must include two shade trees.
D. Median islands.
1. A landscaped median island must be provided between every six single parking rows.
Intervals may be expanded to preserve existing trees on the lot.
2. A landscaped median island must be at least six feet wide.
3. At least three shrubs must be planted in the median island for every 80 feet in length.
E. Island plantings.
1. All required shade trees species must be approved by the arborist division.
2. All required shade trees must have a minimum caliper of three inches and be at least ten feet tall at time of planting.
3. Islands must be installed below the level of the parking lot surface and designed to allow for runoff capture.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), § 10, 7-14-22) Sec. 16-18T.022. Off-street parking requirements.
In addition to the provisions of section 16-28.008(7), which shall apply and are
incorporated herein, the following parking requirements shall apply to all uses approved by special permits. (See also sections 16-28.013 and 16-28.014):
1. Off-street surface parking shall not be located between a building and the street without an intervening building.
2. Parking facilities shall be accessory to a permitted principal use only, provided
that parking spaces serving another principal permitted use may use such facility for shared parking during nonnormal business hours by compliance with subsection (7) below.
3. For office uses minimum requirements unless otherwise stated:
a) All developments shall reserve and designate at least five percent of the employee parking spaces "Carpool Only." Carpool spaces shall be used only by carpool vehicles in which at least two of the persons are employees or tenants of the building. Such spaces shall be located near the building's employee
entrance or other preferable locations within the employee parking areas as approved by the Director of
the Bureau of Traffic and Transportation.
b) All new parking structures shall be built to accommodate vanpool access.
The minimum ceiling height for vanpools is eight feet two inches.
4. For residential uses: See Table I, "Land Use Intensity Ratios", for minimum "parking requirements under appropriate FAR for the development.
5. For non-residential uses minimum requirements unless otherwise stated:
a. Banks, savings and loan institutions, and the like: One space for each 200 square feet of floor area.
b. Business colleges, trade schools, conservatories, dancing schools, and the like: One space for each 200 square feet of floor area.
c. Child care centers, day care centers, prekindergartens, play and other
special schools or day care centers for young children: One space per 600 square feet of floor area. In addition to providing off-street parking, such establishments shall provide safe and convenient facilities for loading and unloading children, as approved by the director, bureau of traffic and transportation.
d. Clubs, lodges, and commercial recreational establishments: One (1) space for each two hundred (200) square feet of floor area.
e. Dormitories: No parking requirements.
f. Eating and drinking establishments:
i. Within Subarea 1: One parking space for each 300 square feet of floor area. Where an
eating and drinking establishment derives more than 60 percent of its gross income from
the sale of malt beverages, wine and/or distilled spirits, it shall be required to have one space for each 225 square feet of floor area. Floor area shall include, in addition to those areas defined in section 16-29.001(13)(b), areas within the existing building footprint where walls have been removed and a permanent roof remains.
ii. Within Subareas 2-6: One parking space for each 100 square feet of floor area. Where an
eating and drinking establishment derives more than 60 percent of its gross income from
the sale of malt beverages, wine and/or distilled spirits, it shall be required to have one space for each 100 square feet of floor area. Floor area shall include, in addition to those areas defined in section 16-29.001(13)(b), areas within the existing building footprint where walls have been removed and a permanent roof remains.
g. Eating and drinking establishments with accessory outdoor dining that is not covered by a permanent structure and which exceeds 25 percent of total gross floor area of the building or business shall have the following requirements: One space for each 600 square feet of the total accessory outdoor dining floor area including the 25 percent nonexempt floor space. Where an eating and drinking establishment derives
more than 60 percent of its gross income from the sale of malt beverages, wine and/or distilled spirits, it shall be required to have one space
for each 450 square feet of floor area.
h. Fraternities, sororities: One space for two beds plus one space for each 200 square feet of floor area designated or occupied other than for sleeping purposes.
i. Hotels and motels: One space per rental unit plus one-half space per employee; one space per 100 square feet of restaurant/lounge gross leasable area; one space per 300 square feet of other convention facilities
(GLA).
j. Nursing homes, convalescent homes, and similar care facilities: One space for four beds.
k. Office uses: No minimum. A maximum of two and one-half spaces for each 1,000 square feet of floor area. Parking during off-peak hours (after 6:00 p.m.) may be shared for other uses.
l. Photocopying shops: One space for each 200 square feet of floor area.
m. Schools, colleges, churches, recreation or community centers and other
places of assembly: One space for each four fixed seats (with 18 inches if bench length counted as one seat or one space for each 35 square feet of enclosed floor area for the accommodation of movable seats in the largest assembly room, whichever
is greater, plus the following:
i. Public or private elementary or middle school: Two spaces for each classroom.
ii. High school: Four spaces for each classroom.
iii. Colleges and universities: Eight spaces for each classroom.
n. For all other non-residential uses located in Subareas 1 and 2: One parking space for each 600 square feet of floor area shall be provided on the site.
o. For all other non-residential uses located in Subareas 3, 4, and 5: One parking space for each 300 square feet of floor area shall be provided on the site.
p. Shelter: One parking space for each on duty staff member, whether paid or unpaid. In addition to staff parking, a space of sufficient size is required for each van, bus or other
vehicle used by the facility and one additional parking space shall be provided for each 2,000 square feet of the facility.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2005-41(06-O-0381), § 43, 7-12-05; Ord. No. 2008- 62(06-O-0038), § 6P(1)-A, 7-7-08; Ord. No. 2009- 24(08-O-1251), § 2V(3), 6-9-09)
Sec. 16-18T.023. Minimum bicycle parking requirements.
See section 16-28.014(6), Bicycle parking requirements.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2019-09(18-O-1581), § 12, 1-31-19) Sec. 16-18T.024. Pedestrian bridges and tunnels.
Pedestrian bridges and tunnels are prohibited when located above or below public streets, private streets which function as public streets connecting two other public streets, or other public rights-of-way.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.025. Zero-lot-line development.
Zero-lot-line subdivision is permitted for residential uses in Subareas 1, 2, 3, 4, and 5, provided a minimum of 1,000 square feet in lot area is provided. The additional requirements of section 16-28.007 shall also apply.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.026. Specific regulations for Subarea 1—Greenbriar
Town Center.
Building façade materials shall consist of the following:
a. Single and two-family: All exterior façades shall be brick, wood, or hardiplank,
(cementious siding). Hardiplank siding shall be a maximum of six inches in width.
b. Multi-family and non-residential:
i. All exterior facades adjacent to and/or visible from a public street shall be predominately at least 51 percent face brick (thin brick prohibited) per vertical wall plane.
Natural stone, split-faced concrete masonry units or integrally colored split-faced concrete masonry units, cast stone trim or three-part stucco (true stucco) may comprise the remaining 49 percent of each building façade.
ii. All exterior facades not adjacent to and/or visible from a public street
shall include the above list with the addition of synthetic stone and synthetic stucco.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), §§ 11, 12, 7-14-22) Sec. 16-18T.027. Specific regulations for Subarea 2—Greenbriar
Neighborhood Center.
Building façade materials shall consist of the following:
a. Single and two-family: All exterior façades shall be brick, wood, or hardiplank,
(cementious siding). Hardiplank siding shall be a maximum of six inches in width.
b. Multi-family and non-residential:
i. All exterior facades adjacent to and/or visible from a public street shall be predominately at least 51 percent face brick (thin brick prohibited) per vertical wall plane.
Natural stone, split-faced concrete masonry units or integrally colored split-faced concrete masonry units, cast stone trim or three-part stucco (true stucco) may comprise the remaining 49 percent of each building façade.
ii. All exterior facades not adjacent to and/or visible from a public street
shall include the above list with the addition of synthetic stone and synthetic stucco.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), §§ 13, 14, 7-14-22) Sec. 16-18T.028. Specific regulations for Subarea 3—Campbellton
Road Mixed-Use Corridor.
1. Drive-through service windows and drive-in facilities shall not be located between the principal structure and the street.
2. Building façade materials shall consist of the following:
a. Single and two-family: All exterior façades shall be brick, wood, or hardiplank,
(cementious siding). Hardiplank siding shall be a maximum of six inches in width.
b. Multi-family and non-residential:
i. All exterior facades adjacent to and/or visible from a public street shall be predominately at least 51 percent face brick (thin brick prohibited) per vertical wall plane.
Natural stone, split-faced concrete masonry units or integrally colored split-faced concrete masonry units, cast stone trim or three-part stucco (true stucco) may comprise the remaining 49 percent of each building façade.
ii. All exterior facades not adjacent to and/or visible from a public street
shall include the above list with the addition of synthetic stone and synthetic stucco.
(Ord. No. 2022-20(22-O-1017), §§ 15, 16, 7-14- 22)
Sec. 16-18T.029. Specific regulations for Subarea 4—Greenbriar
Residential/Commercial.
1. All non-residential permitted uses listed in Table Greenbriar SPI - Permitted Uses shall be restricted in floor area to a maximum of 20 percent of the total development, shall be located within a building that contains street frontage and shall be located on the street-level floor only.
No occupancy permit for such uses shall be issued until a minimum of 50 percent of the total dwelling units are occupied.
2. Building façade materials shall consist of the following:
a. Single and two-family: All exterior façades shall be brick, wood, or hardiplank,
(cementious siding). Hardiplank siding shall be a maximum of six inches in width.
b. Multi-family and non-residential:
i. All exterior facades adjacent to and/or visible from a public street shall be predominately at least 51 percent face brick (thin brick prohibited) per vertical wall plane.
Natural stone, split-faced concrete masonry units or integrally colored split-faced concrete masonry units, cast stone trim or three-part stucco (true stucco) may comprise the remaining 49 percent of each building façade.
ii. All exterior facades not adjacent to and/or visible from a public street
shall include the above list with the addition of synthetic stone and synthetic stucco.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04; Ord. No.
2022-20(22-O-1017), §§ 17, 18, 7-14-22) Sec. 16-18T.030. Specific regulations for Subarea 5—Greenbriar
Medium Density Residential.
All non-residential permitted uses listed in Table Greenbriar SPI - Permitted uses shall be restricted in floor area to a maximum of five percent of the total development, shall be located within a building that contains street frontage and shall be located on the street-level floor only.
No occupancy permit for such uses shall be issued until a minimum of 50 percent of the total dwelling units are occupied.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04) Sec. 16-18T.031. Specific regulations for Subarea 6—Greenbriar
Single-family.
Reserved.
(Ord. No. 2004-20, § 1(Att. A), 5-11-04)
CHAPTER 18U. SPI-21 HISTORIC WEST
END/ADAIR PARK SPECIAL PUBLIC
INTEREST DISTRICT REGULATIONS
Sec. 16-18U.001. Scope of provisions.
The regulations set forth in this chapter, or set forth elsewhere in this part when referred to in this chapter, are the regulations for the SPI-21 Historic West End/Adair Park Special Public Interest District. These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in section 16-18U.003, except that any existing categories of historic protection designated pursuant to chapter 20 of part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this chapter. Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. Whenever the following regulations conflict with provisions of Part 16 other than historic protection regulations, the more stringent regulation shall apply.
The regulations set forth in sections 16-18U.001 through and including section 16-18U.027 shall apply to all properties located within the SPI-21 Historic West End/Adair Park Special Public Interest District, including all subareas within the district. The remaining regulations set forth in section 16-18U.028 through section 16-18U.037 shall apply only to the subareas identified therein.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.002. Statement of intent.
The intent of the council in establishing SPI-21 Historic West End/Adair Park Special Public Interest District as a zoning district is as follows:
1. Implement provisions of the comprehensive development plan incorporating certain recommendations contained in studies of this area, including the comprehensive study known as Historic West End Historic District Livable Centers Initiative (LCI) Plan;
2. Create an urban environment in the commercial area of the West End where people can live, work, meet and play;
3. Encourage the development and redevelopment of the underutilized industrial properties along Murphy Avenue in Adair Park in a commerciallyviable manner that also ensures that future redevelopment provides net positive benefits to the physical environment of the Adair Park community and encourages the growth of a healthy, pedestrianoriented, transit-supportive neighborhood;
4. Improve the aesthetics of the built environment;
5. Encourage a compatible mixture of residential, commercial, cultural and recreational uses;
6. Provide a range of housing types and prices to meet different housing needs;
7. Provide appropriately-scaled, continuous pedestrian oriented uses and activities
adjacent to sidewalks along streets with identified pedestrian needs;
8. Facilitate safe, pleasant and convenient pedestrian circulation and minimize
conflict between pedestrians and vehicles;
9. Provide for development within this area that is compatible with existing low-and moderate-density development within surrounding residential areas;
10. Prevent encroachment of incompatible commercial uses into residential neighborhoods;
11. Ensure pedestrian-oriented building forms;
12. Encourage infill and rehabilitation development within traditionally commercial areas that include proportionately significant residential uses;
13. Provide sufficient parking in an unobtrusive manner;
14. Encourage the use of transit through the location of mixed-use development and
regional entertainment and cultural facilities around a transit-oriented center;
15. Encourage opportunities for economic development, both residential and commercial, where there is a planned relationship between the transportation system and development;
16. Maximize opportunities for pedestrian amenities, including parks, plazas, greenways and public art;
17. Provide sufficient, safe and accessible parks, plazas and greenways for active
and passive enjoyment;
18. Reduce parking requirements by encouraging shared parking and alternative modes of transportation;
19. Encourage development that reflects the village's original scale;
20. Recognize that certain subareas are more attractive to development than others at different times in the development lifecycle, and to not impose onerous requirements on subareas that might prohibit redevelopment; and
21. Address needs for accessibility, safety, and economic development of the Adair
Park neighborhood and commercial/ transitional districts that are in close proximity to the West End MARTA Rail
station and Murphy Avenue.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.003. Boundaries of district and subareas established.
The boundaries of the SPI-21 Historic West End/Adair Park Special Public Interest District are shown on maps in Attachment B which by this reference is incorporated into and made a part of this chapter and this part. The Historic West End/Adair Park Special Public Interest District is divided into ten main subareas and other designated areas as shown on said map Attachment B. The subareas and other designated areas are described as follows:
Subarea 1: Village Center Subarea 2: Commercial Core Subarea 3: RDA Corridor Subarea 4: Neighborhood Commercial Subarea 5: Village Center Residential Subarea 6: Medium Density Residential Subarea 7: Smaller Lot Single-family Subarea 8: Institutional/AUC Subarea 9: Adair Park Live/Work Subarea 10: Candler District Reduced Parking Zone:
All lots within 2,640 feet of the MARTA rail station, measured along a public or private sidewalk, walkway, or street from the transit station lot line, edge of stop platform, or edge of other boarding area, whichever is greatest, to the closest point of the lot. When any
portion of a lot is within the applicable distance, the entire lot shall be
considered within the zone.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2019-09(18-O-1581), § 7.L, 1-31-19) Sec. 16-18U.004. Application procedures.
A special administrative permit shall be required for development in this district as set forth in this section. A special administrative permit (SAP) application and seven copies each of a site plan, landscape plan and elevation drawings of each exterior façade shall be submitted and approved by the director of the bureau of planning prior to the applicant filing for a building permit. All new construction, including additions to existing buildings, expansions of existing outdoor dining, outdoor dining within required sidewalk areas, or any construction which results in increased lot coverage or a modification of the building footprint within this district, shall be subject to said site plan review and approval.
Before making application for a special administrative permit, a pre-application conference between the applicant and the director of the bureau of planning or the director's designee is required to discuss the application and relevant requirements of these regulations. Said preZONING § 16-18U.004 application conference shall be held within 14 days of the date of the request by the applicant, unless a longer period is mutually agreed upon.
All applications for a special administrative permit shall be processed in accordance with the standards and procedures applicable to said SAP applications contained in Chapter 25 of Part 16 except as otherwise modified by this Chapter 18U.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.005. Exemption from special
application permit.
Exemption from the special application permit process will be considered for applications requesting general repairs or renovations, based on the following conditions:
In all subareas:
1. There are no exterior additions to existing buildings;
2. There are no expansions of existing outdoor dining or outdoor dining within required sidewalk areas;
3. There is no construction which results in increased lot coverage or a modification of any building footprint; and
In Subareas 1 through 8:
4. There are no alterations to any exterior building façades visible from the public right-of-way that reduce the number or
amount of window openings or doors, alter façade materials, or decrease the height of the façade.
In addition, the director of the bureau of planning may exempt certain classes of
applications for building permits from detailed review requirements as set forth above upon written findings that generally within SPI districts, the actions proposed are of such a character or of
such a scale as to make detailed reviews and approval by the planning director
unnecessary. Where applications for building permits are determined by reference to such findings to be thus exempted, the permit shall be issued if otherwise lawful.
5. Battery exchange stations shall be permitted where service stations are permitted.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2014-53(14-O-1278), § 2(Attach. B), 12-10-14) Sec. 16-18U.006. Variations.
In connection with the issuance of special administrative permits as is provided herein, the director of the bureau of planning is authorized to receive and decide requests for variations either as is provided at section 16-18.007 within this part or, alternatively, pursuant to the following standards:
(1) There are extraordinary and exceptional conditions pertaining to the particular
piece of property in question because of its size, shape, topography, subsurface
conditions, overhead structures or the existence of sufficient trees in the public right-of-way within ten feet of the property line;
(2) Such conditions are peculiar to the particular piece of property involved; and
(3) Relief, if granted, would not cause substantial detriment to the public good or impair the purposes and intent of the Zoning Ordinance of the City of Atlanta.
The director of the bureau of planning is also authorized to receive and decide
requests for a reduction of the required on-site parking for properties located in the reduced parking zone, to a maximum
reduction of 100 percent of the regular onsite parking requirements given in this section. Parking reductions may be based upon consideration of such factors as adequacy of the existing pedestrian
infrastructure, age of the structure, urban design features of the structure, local
pedestrian accessibility and connectivity, and proposed use for the site.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.007. Reserved.
Sec. 16-18U.008. Permitted principal uses and structures.
A building or premises shall be used for the following permitted uses and structures:
1. See Table SPI-21 Historic West End/ Adair Park—Permitted Uses for permitted principal uses, permitted accessory uses and structures, and special permits.
2. Permitted principal uses:
a. A building or premises shall be used only for the principal purposes as indicated with a "P" in Table SPl-21 Historic West End/Adair Park— Permitted Uses.
b. Uses indicated with a "P(X)" shall not exceed X square feet of floor area. This restriction shall apply to individual uses only. It shall not by itself restrict the overall floor area of buildings or the number of buildings allowed on a single lot.
c. Commercial uses in Subareas 3, 5 and 6 are further restricted as indicated in sections 16-18U.030, 16-18U.032 and 16-18O.029.
3. Special permits: The following are permissible only by special permits of the type indicated in Table SPI-21 Historic West
End/Adair Park - Permitted Uses subject to limitations and requirements set herein or elsewhere in this part, and subject to the applicable procedures and requirements set forth in section 16-25.001 et seq.
a. "SUP" indicates that a special use permit shall be required.
b. "SAP" indicates that a special administrative permit shall be required.
c. "SE" indicates that a special exception shall be required.
4. Merchants may display merchandise outside during regular business hours providing that the display is adjacent to the place of business, sales are conducted directly by the place of business, and the primary business is conducted in an
enclosed space. Merchandise may not be left outside of the enclosed place of business outside of regular business hours unless it is in a secured area adjacent to the place of business.
SPI-21 HISTORIC WEST END/ADAIR PARK—PERMITTED USES P = Permitted
P(S) = Permitted, up to S square feet22 SE = Special Exception SAP = Special Administrative Permit SUP = Special Use Permit X = Not Permitted
SUBAREAS
1: Village Center 6: Medium Density Residential 2: Commercial Core 7: Smaller Lot Single-family 3: RDA Commercial Corridor 8: Institutional/AUC 4: Neighborhood Commercial 9: Adair Park Live/Work 5: Village Center Residential 10: Candler District 1 2 311 4 51
6 2 7 83 9 10
RESIDENTIAL
Single-Family Dwellings
P P P P P P P P P P
Two-Family Dwellings
P P P P P P X P P P
1 2 311 4 51 7 83 9 10 Multi-Family Dwellings
P P P P P P X P P P
Dormitories4 SUP SUP X SUP X X X P SUP P Group Homes5 X X X X X X X X X X
Rooming Houses X X X X X X X X X SUP Shelter SUP SUP SUP X X X X X X X Short-term rentals, subject to the regulations in Atlanta City Code section 20-1001.
P P P P P P P P P P
Single Room Occupancy Residences
X X X X X X X X X SUP
Supportive housing
P P P P P P X P P P
TRANSPORTATION COMMUNICATIONS
Automobile service stations, provided that no service station may be located within 1,500 feet of another service station.
P P X P X X X X P P
Broadcasting towers greater than 70 feet in height6
SUP SUP SUP SUP SUP SUP SUP SUP SUP SUP
Broadcasting towers lower than 70 feet in height6
SAP SAP SAP SAP SAP SAP SAP SAP SAP SAP
Data centers, except where any part of the property is within 2,640 feet of a highcapacity transit stop, as referenced in City Code Section 16-28.014(14).
P P P(8,000) P X X X X P P
Helicopter landing facilities
SUP SUP X SUP X X X SUP SUP SUP
MARTA
structures7
P P P P P P P P P P
Park-for-hire decks
P P SUP P X X X X P P
Park-for-hire surface lots
SUP SUP SUP SUP X X X X SUP SUP
1 2 311 4 51 7 83 9 10 Telecommunications switchboards.8 Data centers are excluded from this use in this district.
P P P P X X X X P P
Truck stops X X X X X X X X X X
RETAIL GOODS AND SERVICES
Automatic teller machines
P P P P P P X P P P
Bakeries and catering
P P P P P(4,000) P(2,000) X P P P
Banks9 P P P P X X X P P P Barber shops, Beauty shops, Nail shops
P P P P P(4,000) P(2,000) X P P P
Drive-through services23
P P X X X X X X P P
Dry cleaning collection stations
P P P P P(4,000) P(2,000) X P P P
Dry cleaning facilities
P P X P X X X X P P
Grocery stores P P P P X X X P P P Laundromats P P P P P(4,000) P(2,000) X P P P Pawn shops X X X X X X X X X X
Photocopying or blueprint shops
P P P P X X X P P P
Plumbing, air cond. service and repair
P P X P X X X X P P
Retail establishments
P P P P X X X P P P
Sales and repair establishments12
P P P P P(4,000) P(4,000) X P P P
Small discount variety stores, provided that no small discount variety store may be located within 5,280 feet of another small discount variety store, and that such establishment shall not exceed 10,000 sq. ft. if not within 200 feet of the rightof-way of an arterial or collector street.
P P P P X X X P P P
Tailoring and dressmaking
P P P P P(4,000) P(4,000) X P P P
Vault-storage facility
P P P P X X X X P P
1 2 311 4 51 7 83 9 10
OTHER COMMERCIAL
Hotels SUP SUP SUP SUP X X X P13 P P Mortuaries and funeral homes
SUP SUP X SUP X X X X SUP SUP
New and used car sales
X X X X X X X X X P(35,000)
Nursing homes, convalescent centers
P P X P X X X P P P
ENTERTAINMENT
Adult businesses
X X X X X X X X X X
Bingo parlors SUP SUP X SUP X X X X SUP SUP Bowling alleys SUP SUP SUP SUP X X X SUP SUP P Museums, art
galleries, libraries14
P P P P SUP
(8,000)
SUP
(8,000)
X P P P
Outdoor enterprises having a duration of 90 days or less15
SAP SAP SAP SAP X X X X SAP SAP
Outdoor enterprises having a duration of more than 90 days15
SUP SUP SUP SUP X X X X SUP SUP
Party houses provided that the use shall be prohibited within 150 feet of a property zoned R-1, R-2,
R-2A, R-2B, R-3,
R-3A, R-4, R-4A,
R-4B, R-5, RG,
MR or a property used for residential purposes measured from property line to property line
SAP SAP SAP SUP X X X SAP SAP SAP
Poolrooms and amusement arcades
SUP SUP SUP SUP X X X X SUP SUP
Restaurants, bars16
P P(8,000) P(8,000) P(8,000) P(8,000) P(4,000) X P(8,000) P(8,000) P Theaters17 P P P P X X X P P P
OFFICES
Clinics18 SUP SUP SUP SUP X SUP X SUP SUP P Offices, studios P P P P P(8,000) P(8,000) X P P P Professional or
service establishments19
P P P P X X X P P P
CIVIC, EDUCATIONAL & RELIGIOUS
Auditoriums X X X X X X X P X P 1 2 311 4 51 7 83 9 10 Business or commercial schools
P P X P X X X P P P
Cemeteries and Mausoleums
X X X X X X X SUP X X
Childcare centers and kindergartens
P P P P SUP SUP X P P P
Churches and synagogues
P P P P SUP SUP X P P P
Clubs and lodges
P P P P X X X P P P
Colleges and universities20
P P X P X X X P P P
Community centers21
SUP SUP X SUP X SUP X P SUP P
Private schools P P X P X X X P P P Public schools P P X P P P P P P P
INDUSTRIAL
Commercial greenhouses
X X X X X X X X X X
Light manufacturing24
X X X X X X X X P P
Heavy manufacturing
X X X X X X X X X X
OTHER
Farmers' market SAP SAP SAP SAP SAP25 SAP25 SAP25 SAP SAP SAP Hospitals SUP SUP X SUP SUP X X SUP SUP P Market gardens P P P P P P26 P
26 P P P
Urban gardens P P P P P SAP SAP P P P Notes:
1. See additional restrictions on commercial uses for this subarea in section 16-18U.032.
2. See additional restrictions on commercial uses for this subarea in section 16-18U.029.
3. See additional restrictions on commercial and entertainment uses for this subarea in section 16-18U.035.
4. Including fraternity and sorority houses. All dormitories, fraternity and sorority houses must have a current official affiliation with an accredited college or university.
5. Including family care homes and congregate care homes
6. And line-of-sight relay devices for telephonic, radio or television communications greater than 70 feet in height
7. Defined as: Structures and uses required for operation of MARTA or a public utility but not including uses involving storage, train yards, warehousing, switching, or maintenance shops
8. Including power generators and other telecommunications relay equipment
9. Including savings and loan associations, and other similar institutions, but not drive-through services unless specifically permitted. See table entry under "Drive-Through Services".
[10. Reserved.]
11. See sections 16-18U.030 for further restrictions in this subarea.
12. For home appliances, bicycles, lawn mowers, shoes, clocks, or similar household goods
13. Containing no more than 100 rooms and not exceeding 75 feet in height
14. And similar profit or non-profit cultural facilities
15. Defined as outdoor amusement enterprises, exhibits, entertainment, meetings, displays or sales areas, or outdoor religious ceremonies
16. Including coffee shops, delicatessens, and taverns, but not drive-through services unless specifically permitted. See table entry under 'Drive-Through Services".
17. Including other commercial recreation establishments with primary activities conducted within fully enclosed buildings
18. Including medical and scientific research, clinical testing, generation of hazardous waste, veterinary (if animals are kept within soundproof buildings), laboratories, and similar uses, excluding blood donor stations
19. But not hiring halls
20. And other institutions of higher learning
21. Including community service facilities, when not owned by a government agency
22. This restriction applies to individual uses only. It does not by itself restrict the size of buildings or the number of buildings on a single lot.
23. See sections 16-18U.011, and 16-18U.021 for further restrictions on location of drive-through services.
24. Including wholesale goods, warehousing, and storage.
25. Farmers' market limited to parcels which meet the minimum lot size requirements and are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
26. Market gardens are limited to parcels which are used as churches, synagogues, temples, mosques and other religious worship facilities or schools.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No. 2009-24(08-O-1251), §§ 2W, 2W(2), 6-9-09; Ord. No.
2009-47(09-O-0844), § 1, 8-25-09; Ord. No. 2009-61(09-O-1076), § 2(2), 10-13-09; Ord. No. 2010-57(10- O-1341), § 1, 10-12-10; Ord. No. 2011-39(10-O-1773), § 3AB, 9-15-11; Ord. No. 2014-22(14-O-1092), § 2-GG, 6-11-14; Ord. No. 2017-41(17-O-1010), § 1, 7-14-17; Ord. No. 2019-20(18-O-1679), § 14, 3-13-19; Ord. No. 2019-66(19-O-1504), § 18, 12-11-19; Ord. No. 2020-23(20-O-1229), § 1, 4-29-20; Ord.
No. 2020-58(19-O-1393), § 45, 10-28-20; Ord. No. 2021-60(21-O-0682), § 41, 12-15-21; Ord. No.
2024-36(24-O-1222), § 9, 9-4-24) Sec. 16-18U.009. Permitted accessory uses and structures.
Accessory uses and structures permitted within this district shall include those customarily accessory and clearly incidental to permitted principal uses and structures and specifically includes clubhouses, pools, and other recreation amenities, parking to serve authorized residential and non-residential uses within the district subject to the restrictions contained elsewhere in this chapter, and electric vehicle charging stations equipped with Level 1, Level 2, and/or DC Fast Charge EVSE.
Accessory parking structures and lots for required parking are permitted within 300 feet of primary use as measured from the nearest property line, without a special exception.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2014-53(14-O-1278), § 2(Attach. B), 12-10-14) Sec. 16-18U.010. Redevelopment requirements.
Nonconforming properties are subject to these regulations to the extent indicated in Part 16, Chapter 24, Nonconformities. Nonconforming properties are required to come into complete compliance with these regulations upon redevelopment or upon loss of nonconforming status, subject to the provisions in Part 16, Chapter 24, Nonconformities.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.011. Transitional uses and
yards.
1. Adjoining lot with same frontage: Where a lot in this district abuts a lot in any R-1 through R-G, MR, RLC or PD-H district, or subareas 6, or 7 of this district, at the side along the same street frontage, and without an intervening street, such lot within this district, or the first 100 feet on such lot if it is wider than 100 feet, shall not be used for any drive-through service window or drive-in facility, car wash, service station, mortuary or funeral home, sales lot for automobiles, repair garage, or paint and body shop even where otherwise specifically authorized.
2. Transitional height planes.
a. No portion of any structure shall protrude through a height limiting plane beginning the specified number of feet above the point set forth in subsection
16-18U.011(2)(b) below and extending inward over the SPI-21 district at an angle of 45 degrees. The following districts shall be considered "protected districts" for purposes of this section 16-18U.011(2):
i. R-1 through R-5;
ii. RG-1 and RG-2;
iii. MR-1, MR-2, and MR-MU; and iv. Landmark, Historic, PD, and SPI districts and district subareas having uses and densities predominantly similar to those permitted in the district classifications listed in subsections (i) through (iii) above.
b. Proximity to districts and measurement applications:
i. For parcels in an SPI-21 district that are contiguous to a protected district, the transitional height plane shall be measured beginning 35 feet above the required SPI-21 setback or transitional yard adjoining the common property line with such protected district.
ii. For parcels in an SPI-21 district that are not contiguous to but are within 150 feet of a protected district, the transitional height plane shall
be measured beginning 15 feet above the nearest lot line of the protected district, provided this transitional height plane shall not extend more than 150 linear feet (measured along the ground) from the protected district up to and into the SPI-21 district. (See diagrams at section 16-29.001(62).)
c. The purpose and intent of this provision is to provide protection for the named
protected districts from nearby looming structures regardless of the presence of an intervening public right-of-way or park or space, public or private street or alley, or any lot or parcel remnant.
d. Transitional height plane measurements shall be applied to parcels on a point-bypoint basis and not average grade.
3. Transitional yards:
a. Where any subarea of this district adjoins an R-1 through R-5, R-G, MR, RLC or
PD-H district, or Subareas 6 or 7 within this district without an intervening street, a minimum of 20 feet is required which
shall not be used for the purpose of parking, paving, loading, servicing or any other activity with the exception of private alleys or drives up to ten feet in width. Such yards shall be planted as
approved by the city arborist and maintained as a landscaped strip.
b. Screening: In addition to the above transitional yard requirements, permanent opaque walls six feet in height shall be provided and shall be maintained in sightly condition.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2019-09(18-O-1581), § 10.17, 1-31-19) Sec. 16-18U.012. Development controls.
See Table SPI-21 Historic West End/Adair Park - Development Controls and Site Limitations for bulk limitations, maximum building coverage, public space requirements, minimum open space requirements, and maximum height.
For purposes of this chapter, and notwithstanding the provisions of Code Section 16-29.001(24), mixed-use development is defined as any development which contains as principal uses both residential and non-residential uses on the same development site, and in which both of such uses are at least 20 percent of the total floor area, excluding accessory uses.
TABLE SPI-21 HISTORIC WEST END/ADAIR PARK—DEVELOPMENT CONTROLS AND SITE
LIMITATIONS
SUBAREAS
1: Village Center 2: Commercial Core 3: RDA Corridor 4: Neighborhood Commercial 5: Village Center Residential 6: Medium Density Residential 7: Smaller Lot Single-family 8: Institutional/AUC 9: Adair Park Live/Work 10: Candler District 1 2 3 4 5 6 7 8 9 10 Nonresidential FAR (base) or Maximum Percentage of Development
2.5 2.5 1.5 1.0 20% 5% None 3.0 2.5 5.0 Residential FAR (base)
2.0 1.0 0.696 0.696 2.3 0.696 0.5 3.2 0.696 3.2 Combined FAR
without bonuses
3.5 3.5 2.196 1.696 2.3 0.696 0.5 3.2 3.196 8.2 Additional
Open Space Bonus
YES YES YES YES YES NO NO NO YES YES
Ground Floor Commercial Bonus
YES YES YES YES YES NO NO NO YES YES
Combined Maximum FAR with bonuses
4.0 4.0 2.696 2.696 3.2 0.696 0.5 3.2 3.696 8.2 Maximum
Building Coverage (percent of net lot area) 85% 85% 85% 85% 85% 85% 50% 85% 85% 85% Residential Usable Open Space Requirement (UOSR)
LUI LUI LUI LUI LUI LUI LUI LUI LUI LUI
Nonresidential Public Space Requirement, as a % of net lot area 10% 10% 10% 10% 10% None None 10% 5% None New Street
Incentive
YES YES NO YES YES YES NO YES YES YES
On-street Parking Incentive
YES YES YES YES YES YES NO YES YES YES
1 2 3 4 5 6 7 8 9 10 Minimum Lot Size None None None None 5,000 sq. ft.
2,000 sq. ft 5,000 sq. ft None None None Minimum Street Frontage None None None None 40' 40' 40' None None None Minimum
Façade Height 24 feet 24feet 24 feet 24 feet None None None None None None Maximum
Height 225* 72 feet 46 feet 46 feet 72 feet 46 feet 35 feet 72 feet 72 feet 225 feet
*Buildings and portions of buildings within 150' of Ralph David Abernathy Boulevard, shall have a maximum height of 72'.
1. Bulk Limitations:
a. Maximum permitted floor areas without bonuses:
i. For nonresidential uses, the ratio of floor area to net lot area shall not exceed the amount indicated under "Maximum Nonresidential FAR" in Table SPI-21 Historic West End/Adair Park - Development Controls and Site Limitations for each subarea.
ii. For residential uses, the ratio of floor area to lot area shall not exceed the amount indicated under "Maximum Residential FAR" in Table SPI-21 Historic West End/Adair Park - Development Controls and Site Limitations for each Subarea (See section 16-18U.012(2)).
iii. For developments that combine residential and non-residential uses, the ratio of floor area to net lot area shall not exceed the sum of the amounts indicated under "Maximum Residential FAR" and "Maximum Nonresidential FAR" in Table SPI-21 Historic West End/Adair Park - Development Controls and Site Limitations for each subarea, but not greater than the maximum floor
areas permitted for each (See section 16-29.001(24)).
b. Maximum permitted floor area with bonuses: Under no circumstances shall the ratio of floor area to gross lot area of any development with bonuses exceed the amount indicated under "Maximum Combined FAR With Bonuses" indicated in Table SPI-21 Historic West End/Adair Park
- Development Controls and Site Limitations for each subarea.
2. Residential uses may use Net Lot Area or Gross Lot Area when calculating
maximum permitted residential floor area, provided that Usable Open Space Requirements (UOSR) are calculated based on the same lot area.
3. Minimum open space requirements: When either the residential or non-residential component of the development is a minor
use of less than 20 percent of the total floor area minimum open space requirements do not apply to such minor use.
a. For residential uses, including all residential components of mixed use developments: Open space requirements as indicated on Table I, "Land Use Intensity Ratios" shall be
required for Useable Open Space (UOSR) only.
b. For non-residential uses, including all non-residential components of mixed-use developments: Public Space requirements shall be as indicated in Table SPI-21 Historic West End/Adair Park — Development Controls and Site Limitations.
(See section 16-28.012 for definitions and measurements. Required yards and requirements for sidewalk
and supplemental zone widths that are constructed on private property may be counted towards this requirement. Such public space may include planted areas, fountains, community
gardens, parks plazas, hardscape elements related to sidewalks and plazas, and similar features which are located on private property.)
c. For mixed-uses: The sum of minimum open space requirements specified in subsections a. and b.
above for non-residential and residential shall be met.
4. Residential balconies: Balconies for residential units, which are enclosed on not more than three sides, may be counted towards UOSR for a maximum depth of
six feet.
5. Additional open space bonus: If indicated for a subarea in Table SPI-21 Historic
West End/Adair Park - Development Controls and Site Limitations, developments in that subarea shall be permitted a residential bonus of two square feet of residential floor area for each one square foot of open space provided above the
minimum required herein. Said bonus shall be permitted provided that open space:
a. Shall provide active or passive recreational amenities;
b. Shall be no greater than 24 inches above or below the adjacent public sidewalk for a minimum distance of 15 feet from the beginning of the adjacent sidewalk;
c. Shall be visible and accessible from any point along 90 percent of any adjacent sidewalk; and
d. Shall permit and encourage pedestrians to walk on a minimum of 80 percent of the surface of the parcel excluding fountains, pedestrian furniture, public art and similar elements.
6. Ground-floor commercial bonus: If indicated for a subarea in Table SPI-21 Historic West End/Adair Park — Development Controls and Site Limitations, developments that provide street-fronting, sidewalk level retail establishments or eating and drinking establishments
that comprise a minimum of 20 percent of the building foot print and meet all of the requirements of section 16-18U.017(1) shall be permitted a residential floor
area bonus of three additional square feet for every one square foot of said space built.
7. New streets incentive: New public streets, or private streets which function as public streets may be counted towards UOSR
and public space requirements provided the following criteria are met:
a. The new streets connect two other public streets or private streets;
and
b. The new streets meets the requirements of section 16-18U.014; and
c. The maximum width of said streets shall be 38 feet; and
d. The new streets shall include two on-street parallel parking lanes, two travel lanes and sidewalk extensions at intersections; and
e. When adjacent to a park area, new streets shall meet all above requirements along each park edge.
f. Gates shall not be permitted across said streets.
8. On-street parking incentive: New onstreet parking may be counted towards UOSR or public space requirements
provided the following criteria are met:
a. No on-street parking currently exists in the public right-of-way adjacent
to the project area for which credit is sought; and
b. The new on-street parking is located where there is no existing street lane; and
c. Sidewalk extensions are provided at street intersections where appropriate; and
d. All other sidewalk requirements of this chapter are met.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2019-54(19-O-1380), § 1, 10-16-19; Ord. No. 2026- 07(26-O-1008), § 1, 3-11-26)
Sec. 16-18U.013. Site limitations.
1. Minimum building façade heights: Buildings shall have a minimum façade height along each façade adjacent (within 30 feet) to any sidewalk or supplemental zone as shown in Table SPI-21 Historic West End/Adair Park - Development Controls and Site Limitations.
2. Maximum building heights: In addition to the requirements of transitional height planes specified in section 16-18U.011(2), buildings shall have a maximum height as shown in Table
SPI-21 Historic West End/Adair Park - Development Controls and Site Limitations.
3. As indicated in Table SPI-21 Historic West End/Adair Park — Maximum Block Lengths,
new development proposing to contain an entire block face greater than 800 feet in length shall be traversed by streets that create block faces no more than the indicated Maximum Block Length, except when topographical conditions prevent the introduction of new streets as required, or to allow new streets to coincide with an existing street grid. For the purposes of this chapter, a block face shall be measured from the back of sidewalk clear zones or required supplemental zones. Such streets shall function as public streets and shall connect two other public streets or private streets that meet the requirements of section 16-18U.012(8).
4. Requirement for continuation of existing street network: Properties adjacent to the rightof-way of existing public streets which dead-end or cul-de-sac shall provide a street connection to that existing right-of-way and shall meet the requirements of section 16-18U.012(8) and section 16-18O.014, unless existing site topography does not permit such a connection to be made as determined by the commissioner of the department of transportation, or his/her designee.
TABLE SPI-21 HISTORIC WEST END/ADAIR PARK—MAXIMUM BLOCK LENGTHS
SUBAREAS
1: Village Center 2: Commercial Core 3: RDA Corridor 4: Neighborhood Commercial 5: Village Center Residential 6: Medium Density Residential 7:Smaller Lot Single-family 8: Institutional/AUC 9: Adair Park Live/Work 10: Candler District 1 2 3 4 5 6 7 8 9 10 Maximum Block Length, in feet 600 600 600 600 600 600 600 None 600 None (Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No. 2020-33(20-O-1381), § 38, 6-23-20) Sec. 16-18U.014. Sidewalks and setbacks.
Public sidewalks shall be located along all public streets and shall have minimum widths as specified herein. Sidewalks shall consist of two (2) zones: a street furniture and tree planting zone, and a clear zone.
SPI-21 HISTORIC WEST END/ADAIR PARK, SUBAREAS 1—9
SIDEWALK AND SETBACK REQUIREMENTS
SUBAREAS
1: Village Center 2: Commercial Core 3: RDA Corridor 4: Neighborhood Commercial 5: Village Center Residential 6: Medium Density Residential 7: Smaller Lot Single Family 8: Institutional/AUC 9: Adair Park Live/Work
ALL MEASUREMENTS ARE IN FEET
123456789 Minimum Tree Planting and Street Furniture Zone Width 5 5 5 5 5 5 5 5 5 or None* Minimum Clear Zone Width 10 10 10 10 10 6 6 10 10 Minimum Supplemental Zone Width 5 or None* 5 or None* 5 or None* 5 or None* 9 or 5** 9 or 5** See Front Yard 5 or None* 5 or None* Minimum Side Yard not adjacent to street 20 or None† 20 or None† 20 or None† 20 or None† 15 or None† 15 or None† 5 15 or None† 20 or None† Minimum Side Yard adjacent to street see supplemental zone see supplemental zone see supplemental zone see supplemental zone see supplemental zone see supplemental zone 10 see supplemental zone see supplemental zone Minimum Rear Yard 20 or None† 20 or None† 20 or None† 20 or None† 20 15 15 25 20 or None† Minimum Front Yard see supplemental zone see supplemental zone see supplemental zone see supplemental zone see supplemental zone see supplemental zone 20 see supplemental zone see supplemental zone *Minimum width is five feet on streets that function as arterial and collector streets, none otherwise.
**Minimum supplemental zone width is nine feet on streets that function as arterial and collector streets, five feet otherwise.
†Nonresidential uses: None. Residential use: Setback may be reduced to zero when no residential windows are adjacent to such yard.
SPI-21 HISTORIC WEST END/ADAIR PARK, SUBAREA 10—SIDEWALK AND SETBACK REQUIREMENTS
ALL MEASUREMENTS ARE IN FEET
RDA BLVD
METROPOLITAN
PKWY SHELTON AVE. MURPHY AVE.
Minimum Tree Planting and Street Furniture Zone Width None, except 5' for a distance of 40' from the corner of Murphy Avenue, measured from the outer edge of the curb.
None. None, except 5' for a distance of 200' from the corner of Murphy Avenue None, except 5' for a distance of 40' from the corner of Ralph David Abernathy Blvd, and 5' for a distance of 200' from the corner of Shelton Ave.
Minimum Clear Zone Width 8' except 10' for a distance of 40' from the corner of Murphy Avenue, measured from the outer edge of the curb.
7', except 8' for 200' in front of main entrance where not prevented by existing building or grass berm 7', except 10' for a distance of 200' from the corner of Murphy Avenue None, except 10' for a distance of 40' from the corner of Ralph David Abernathy Blvd, and 10' for a distance of 200' from the corner of Shelton Ave.
Minimum Supplemental Zone Width None None None None Minimum Side Yard Non-residential: None Residential: 15, or none for zero-lot-line development Minimum Rear Yard Non-residential: None
Residential: 20 The following regulations shall apply to all public sidewalks:
1. Street furniture and tree planting zone requirements: The street furniture and tree planting zone shall have a minimum width as specified in SPI-21 Historic West End/Adair Park - Sidewalk and Setback Requirements. Said zone shall be located immediately adjacent to the curb and shall be continuous. Said zone shall meet the tree planting requirements of section 16-18U.014(3). In addition to the required planting of trees, this zone may also be used for the placement of street furniture including utility poles, waste receptacles, fire hydrants, traffic signs, newspaper vending boxes, bus shelters, bicycle racks and similar elements in a manner that does not obstruct pedestrian access or motorist visibility and as approved by the director of the bureau of planning.
2. Clear zone requirements: The clear zone shall be a minimum width as specified in SPI-21 Historic West End/Adair Park —- Sidewalk and Setback Requirements. Said zone shall be located immediately contiguous to the street furniture and tree planting zone and shall be continuous. Said zone shall be hardscape, and shall be unobstructed for a minimum height of eight feet except as authorized in section 16-18U.016(7).
3. Street tree planting requirements: Street trees are required and shall be planted in the ground a maximum of 50 feet on center within the street furniture and tree planting zone and spaced equal distance between street lights. All newly planted trees shall be a minimum of three inches in caliper measured 36 inches above ground, shall be a minimum of 12 feet in height, shall have a minimummature height of 40 feet, and shall be limbed up to a minimum height of seven feet.
Trees shall have a minimum planting area of 40 square feet. All plantings, planting replacement and planting removal shall be approved by the city arborist. The area between required plantings shall either be planted with evergreen ground cover such as mondo grass or liriope spicata or shall be paved as approved by the director of planning.
4. Tree grates: Tree grates are not required where all sidewalk width requirements are met. Where tree grates are required or otherwise installed, they shall be a minimum of five feet by eight feet, shall be a type specified by the director of planning in accordance with uniform design standards utilized by the director for placement of such objects in the public right-of-way, and shall be placed within the street furniture and tree planting zone. Where tree grates are not required or otherwise installed, tree planting areas shall be permitted to be planted with evergreen ground cover such as mondo grass or liriope spicata.
5. Paving: In Subareas 1 through 8, all paving within the street furniture and tree planting zone shall be a type specified by the director of planning in accordance with uniform design standards utilized by the director for placement of such objects in the public right-of-way.
6. Nothing shall be erected, placed, planted or allowed to grow in such a manner as to impede visibility within visibility triangles at street intersections between the heights of 21 /2 feet and
eight feet above grade. See section 16-28.008(9), Visibility at Intersections.
7. No awning or canopy shall encroach beyond the clear zone.
8. Where property within this district abuts an R, R-G, MR, PD-H, or LW district without an intervening street, the sidewalk area within 20 feet of such districts shall taper as necessary to provide a smooth transition to the existing R, R-G, MR, PD-H, or LW districts sidewalk. In the event that the abutting R, R-G, MR, PD-H or LW district has no existing sidewalk, the sidewalk shall taper to a width of six feet.
9. Decorative pedestrian lights, where installed, shall be placed a maximum of 50 feet on center and spaced equal distance between required trees along all streets. Where installed, said lights shall be located within either the street furniture and tree planting zone or the supplemental zone. All said lights shall be Atlanta Type "C" as approved by the planning bureau.
10. Every commercially reasonable effort shall be made to place utilities underground or to the rear of structures to allow for unobstructed use of sidewalks.
11. Trash receptacles or similar elements, where installed, shall be a type specified by the director of planning in accordance with uniform design standards utilized by the director for placement of such objects in the public right-of-way and shall be placed within the street furniture and tree planting zone.
12. Entryways doors shall not open into the clear zone.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.015. Supplemental zone.
For purposes of these regulations, the area between any building, parking garage, or parking lot and the required sidewalk, when no intervening building exists, shall be defined as the supplemental zone. Supplemental zones shall meet the following requirements. Except as otherwise specified below, the square footage contained within a supplemental zone which meets all the following supplemental zone requirements may be counted towards UOSR or public space requirements.
1. Supplemental zone general requirements:
a. When sidewalk level residential units are provided, supplemental zone shall
be landscaped with the exception of terraces, porches, stoops and walkways, which may occupy a maximum of 2
/3 of the supplemental zone area;
b. Terraces, porches and stoops shall have a maximum finished floor height of 24 inches above finished-grade, unless existing topographical considerations render this requirement unreasonable, subject to the provisions in section 16-25.002(3);
c. The supplemental zone shall be no more than 24 inches above the adjacent public sidewalk for a minimum linear distance of 15 feet from the
nearest edge of the adjacent public sidewalk, unless existing topographical considerations render this requirement unreasonable; and
d. Any authorized walls surrounding landscaped and grassed areas shall not exceed a maximum height of 24 inches, except retaining walls, which shall not exceed a maximum height of 36 inches unless existing topography requires a retaining wall of greater height.
e. Fencing permitted only when:
i. The supplemental zone is located between sidewalk level residential units and the adjacent street; or ii. Said fencing is used to separate
authorized outdoor dining from the required sidewalk.
2. Supplemental zone widths: Along front and side facades shall be a minimum
width as specified in SPI-21 Historic West End/Adair Park - Sidewalk and Setback
Requirements.
3. Supplemental zones containing a depth of 15 feet or less shall meet the following additional requirements:
a. No balcony shall encroach more than ten feet into the supplemental zone area.
b. Shall not be counted towards UOSR or public space requirements unless visible and accessible to the general public from the adjacent public sidewalk, with the exception of areas adjacent to sidewalk level residential units.
4. Supplemental zones containing a depth greater than 15 feet shall be counted
towards UOSR or public space requirements only when the following additional requirements are met:
a. Shall permit and encourage pedestrians to walk on a minimum of 80 percent of the surface of the supplemental zone excluding fountains, pedestrian furniture, public art and similar elements.
b. When adjacent non-residential ground floor uses are provided, shall be visible and accessible from any point along 90 percent of any adjacent sidewalk.
c. When adjacent non-residential ground floor uses are provided, all sides of buildings fronting said zone meet the requirements of section 16- 18U.017(1).
d. When adjacent residential ground floor uses are provided, shall provide a pedestrian walkway from said space to the adjacent public sidewalk. Said pedestrian walkway shall be perpendicular to the street and shall connect directly to the public sidewalk and shall be uncovered and open to
the sky along its entire length.
5. Developments of greater than one acre in area and adjacent to existing transit stops which have no shelters shall provide a
shelter within the supplemental zone for a minimum of one such stop. The design
and location of such stop shall be approved by the director of the bureau of planning.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.016. Relationship of building to street.
1. For purposes of this chapter, sidewalk-level shall be defined as any floor of a building located within 30 feet of a sidewalk with a finished-floor elevation less than or equal to five feet above the adjacent sidewalk or less than or equal to five feet below the adjacent sidewalk. "Adjacent" shall be defined ad "within 30 feet."
2. Building floors shall be delineated at third story above sidewalk level and lower and shall be executed through windows, belt courses, cornice lines or similar architectural detailing.
3. The primary pedestrian entrance for pedestrians to access all sidewalk level uses and business establishments with street frontage:
a. Shall face and be visible from the street.
When located adjacent to a storefront street, said entrance shall face and be visible from such street.
b. Shall be directly accessible and visible from the sidewalk.
c. In Subareas 1 through 8, shall remain unlocked during business hours for nonresidential uses. In Subareas 9 and 10, shall either remain unlocked during business hours for non-residential uses, or may allow entry upon request as part of
an entry security system, provided that all other public entrances utilize a similar entry system.
d. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five
foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit.
This provision shall not apply to singlefamily and two-family residential structures.
4. A street address number shall be located directly above the primary building entrance, shall be clearly visible from the sidewalk and shall be a minimum of six inches in height.
5. Buildings with residential uses at the sidewalk level shall meet the following regulations:
a. All primary pedestrian entrances adjacent to a public sidewalk but within shall be linked to the public sidewalk with a
pedestrian walkway a minimum of five feet wide. Said pedestrian walkway shall be perpendicular to the street and shall be permitted to share said walkway with
one adjacent unit.
b. All such buildings with more than four residential units that are adjacent to the sidewalk shall have individual entrances to such units directly accessible from the sidewalk and shall open directly onto the adjacent sidewalk, park, plaza, terrace
or porch adjacent to the sidewalk. All pedestrian walkways providing such access shall be perpendicular to the street and shall be permitted to share said
walkway with no more than one adjacent unit.
c. Such buildings shall have windows at sidewalk level on each street frontage façade that are substantially similar in size to the sidewalk level front façade
windows.
6. Along all streets, parking, storage or digital industry switchboards, power generators and other relay equipment and rooms housing such equipment shall be permitted, with the exception that such uses shall not occupy a minimum depth of 20 feet of the ground floor street frontage beginning at any building façade along the public sidewalk. Said buildings shall meet the following additional requirements:
a. Shall meet the requirements of section 16-18U.017(1) except at ingress and egress points into the structure and when
topographical conditions prevent such treatment; or
b. Shall meet the requirements of section 16-18U.016(5) except at ingress and egress points into the structure and when
topographical conditions prevent such treatment.
7. Sidewalk arcades: Buildings with nonresidential uses at the sidewalk level may have sidewalk arcades, which shall meet the following regulations:
a. Shall provide an at grade sidewalk surface.
b. Arcade supports shall be a maximum width of five feet.
c. Shall provide a minimum of 25 feet of clear unobstructed space between arcade
supports.
d. A building with a sidewalk arcade shall meet the requirements of section
16-18U.017.
e. Shall provide a minimum clear zone width of 15 feet and when located on streets
which function as arterial streets or Storefront streets, shall provide a minimum supplemental zone width of five feet.
8. Fences and walls shall meet the following regulations:
a. For residential uses adjacent to the sidewalk, fences in Subareas 1 through 8 shall not exceed 42 inches in height when located between the primary building
and the street or between any supplemental zone and the adjacent street.
For non-residential uses adjacent to the sidewalk, fences are prohibited when
located between the building and the sidewalk except where specifically authorized elsewhere in this chapter for outdoor dining.
b. In Subareas 1 through 8, retaining walls located adjacent to a sidewalk along a
public street shall not exceed a height of two feet and the combined height of a
fence where otherwise authorized and retaining wall shall not exceed a height of five feet, unless existing topography prohibits retaining walls of a lesser height.
Retaining walls shall be finished poured concrete or shall be faced with stone,
brick or smooth stucco. See also section 16-29.001(25)(b).
c. No walls, except retaining walls, shall be located between the street and any building, with the exception of screening for authorized off-street loading areas.
9. In Subareas 1 through 8, no barbed wire, razor wire, chain link fence or similar elements shall be visible from any public plaza, ground level or sidewalk level outdoor dining area or public right-of-way.
10. Gasoline fuel dispenser structures and associated vehicular services such as air pumps and car washes shall not be located between a building and the street.
11. In Subareas 1 through 8, building façade materials shall consist of the following:
a. Single and two-family: All exterior façades shall be brick, wood, or hardiplank,
(cementious siding). Hardiplank siding shall be a maximum of six inches in width.
b. Multi-family and non-residential:
i. All exterior façades adjacent to a public street shall be brick, stone, cast stone, or true stucco.
ii. All exterior façades not adjacent to a public street shall be brick, stone,
cast stone, true stucco, concrete masonry units, split-faced concrete, or split-faced block.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2026-05(26-O-1001), § 13, 2-25-26) Sec. 16-18U.017. Specific regulations for storefront streets.
Properties which front streets indicated in Exhibit B as Storefront Streets shall meet the following regulations:
1. Street-fronting buildings including parking decks shall meet the following sidewalk level requirements:
a. The length of façade without intervening fenestration or entryway shall not exceed 20 feet.
b. For buildings with ground floor commercial uses, fenestration shall be provided for a minimum of 65 percent
of the length of the frontage. For buildings with ground floor residential usage, fenestration shall be provided for a minimum of 30 percent of the length of the frontage. Frontage area shall be determined as follows:
i. Beginning at a point not more than three feet above the sidewalk, to a height no less than ten feet above the sidewalk or, ii. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three or more feet above the sidewalk or iii. Beginning at a point not more than sidewalk level, to a height no less than ten feet above the finished floor elevation when the finished floor elevation is below the sidewalk.
c. Fenestration shall not utilize painted glass, reflective glass or other
similarly treated or opaque windows.
Entrances may be counted towards fenestration requirements.
d. For parking decks, commercial uses shall occupy a minimum depth of 20 feet of the ground floor street frontage beginning at any building façade along the public sidewalk, except at
ingress and egress points. Such commercial uses located in this area shall meet the requirements of section 16-18U.017.
2. Minimum building façade height: 24 feet along each façade visible from the public right-of-way.
3. Security gates and screens installed on any façade visible from the public rightof-way shall be constructed of an openwork design, shall be fully retractable, and
shall be fully retracted during business hours.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.018. Signage.
Signs shall be allowed as in 16-28A. Sign Ordinance and as specifically allowed within each sub-area as provided for herein.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2019-35(19-O-1056), § 1, 6-26-19) Sec. 16-18U.019. Loading areas, loading dock entrances and building mechanical and accessory features.
1. Loading areas: Loading areas shall be paved with impervious materials and in Subareas 1—8, they shall be screened so as not to be visible from any public plaza, ground level or sidewalk level outdoor dining area, public sidewalk or public right-of way. Loading areas serving residential uses in Subareas 1—8 shall be enclosed with opaque walls six feet in height.
2. Dumpsters: Dumpster areas shall be paved with impervious materials and shall be screened so as not to be visible from any public plaza, ground level or sidewalk level outdoor dining area, public sidewalk or public right-of way. In addition, dumpsters serving residential uses shall be enclosed with opaque walls six feet in height.
3. In Subareas 1—8, Loading dock entrances for non-residential uses shall be screened so that loading docks and related activity are not visible from the public right-of-way.
4. Building mechanical and accessory features:
a. When located at ground level, shall be located to the side or rear of the principal structure and shall be in the location of least visibility from the public right-ofway. Screening with plant or fence materials shall be required if the equipment is otherwise visible from the public rightof-way.
b. When located on rooftops shall be incorporated in the design of the building and screened with building materials
similar to the building.
c. Shall not be permitted between the building and any public street.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.020. Off-street loading
requirements.
See Table of Loading Requirements, Section 16-28.015 Off-street Loading Requirements.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.021. Curb cuts, driveways,
drive-through lanes, and parking structures.
1. All sidewalk paving materials shall be continued across any intervening driveway at the same prevailing grade and cross slope as on the adjacent sidewalk clear zone.
2. Driveways shall have a band of textured concrete adjacent to the street that is in-line with and equal in width to the street furniture zone and shall have a textured band of concrete adjacent to the sidewalk which is in-line with the supplemental zone and a minimum width of five feet from the sidewalk.
3. In Subareas 1—8, driveway and curb cut widths shall be 24 feet for two-way entrances and 12 feet for one-way entrances, unless otherwise permitted by the commissioner of the department of transportation.
4. No circular drives shall be located between any building and any public street with the exception of hotels.
5. Drive-through service lanes, when permitted, shall not be located between any building and the sidewalk.
6. Curb cuts and driveways shall not be permitted on any street that functions as an arterial street or collector street when access may be provided from a side or rear street located immediately adjacent to a contiguous property, with the exception of hotel patron drop-off drives.
7. In Subareas 1—9, unless authorized by section 16-18U.021(4), driveways, except for a driveway to reach the side yard or rear yard or an on-site parking facility, are not permitted between the sidewalk and a building, and shall be perpendicular to any adjacent street.
8. No more than one curb cut shall be permitted for each development, provided that properties with more than one street frontage may have one curb cut located on each street frontage.
9. Entrances to garages and carports that serve a single residential unit shall face the rear yard, or a side yard that has no street frontage.
10. In Subareas 1—9, all contiguous groundfloor residential units shall share one common drive, located in rear yards or side yards without street frontage, to serve garages, carports and parking areas.
11. In addition to section 16-28.028, parking deck façades shall have the appearance of a horizontal storied building.
12. Notwithstanding the provisions of Section 16-28.006(10), a common or joint driveway may be authorized by the director of the bureau of planning when adjacent lots have direct vehicular access to a street, and a driveway from a private street which functions as a public street may be authorized by the director of the bureau of planning, based on traffic considerations, when a perpetual easement agreement is agreed upon by all affected property owners and a copy of such agreement is provided to the bureau of planning.
13. All developments, including parking decks, shall have sidewalks a minimum width of four feet connecting ground level parking to the public sidewalks and to all building entrances.
See Section 16-18U.023, Minimum Landscaping for Parking Lots, Barrier Requirements.
14. No drop-off lanes shall be permitted along public streets.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2008-67(08-O-0196), § 12, 7-21-08; Ord. No. 2020- 33(20-O-1381), § 39, 6-23-20)
Sec. 16-18U.022. Lighting, security, and maintenance requirements.
1. All lighting including all parking decks and lots and lit canopies shall reduce light spillage onto residentially used properties by providing cutoff luminaries that have a maximum 90 degree illumination.
2. All lighting that up-lights trees, buildings or other elements, shall be located a minimum height of eight feet above the sidewalk, driveway or pedestrian area when not located within completely landscaped areas.
3. All surface parking lots and structures, whether a nonconforming principal use or accessory use, and whether commercial or noncommercial, shall have the following minimum requirements:
a. Lighting shall be provided throughout all parking facilities to equal a minimum of two (2.0) foot candles of light. A footcandle of light is a uniformly distributed flux of one lumen on a surface of one
square foot in area. Where applicable, public street lighting may be utilized to either partially or totally fulfill the lighting requirements; however, where such street lighting is removed, it shall be the responsibility of the parking facility to independently provide these required
levels of illumination.
b. Parking facilities shall be maintained in a clean, safe and sanitary condition. Parking spaces and driving lanes shall be clearly defined and maintained as such.
Parking lots shall not be operated when any damage impairs the drivability of the parking lot. See section 16-28.014 for additional requirements.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.023. Minimum landscaping for surface parking lots, barrier requirements.
The requirements of City of Atlanta Code of Ordinances, Chapter 158 Vegetation, Article II, Tree Protection, Section 30, Parking Lot Requirements shall apply to this district except as modified as follows:
1. Said parking lot requirements shall apply to all lots regardless of size;
2. All parking bays shall be terminated with a landscaped strip a minimum width of five feet and equal to the length of the parking bay.
3. All required landscaped areas shall be planted with evergreen groundcover or
shrubs with a maximum mature height of 30 inches; and
4. All required landscaped buffer areas and strips of any length shall have a minimum of one tree with a minimum caliper of 2.5 inches.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.024. Off-street parking requirements.
In addition to the provisions of section 16-28.008(7), which shall apply and are
incorporated herein, the following parking requirements shall apply to all uses approved by special permits. (See also sections 16-28.013 and 16-28.014):
1. Off-street surface parking shall not be located between a building and the street without an intervening building, with
the following exceptions:
a. Parcels in Subarea 9 that have frontages on both Murphy Avenue and Allen Street shall be allowed to
locate parking between a building and Murphy Avenue if such parking cannot be accommodated elsewhere on the site.
b. In Subarea 10, this restriction shall apply to buildings that are located
within 30 feet of the sidewalk.
2. Parking facilities shall be accessory to a permitted principal use only, provided
that parking spaces serving another principal permitted use may use such facility for shared parking during nonnormal business hours by compliance with the following:
i. The arrangement shall avoid conflicting parking demands and provide for safe pedestrian circulation and
access;
ii. All shared parking spaces shall be clearly marked; and iii. An applicant shall submit the following information as part of the application to reduce parking
requirements and avoid conflicting parking demands:
a) A to-scale map indicating location of proposed parking spaces;
b) Hours of business operation of nonresidential parking users;
c) Written consent of property owners agreeing to the shared parking arrangement;
d) Copies of parking leases.
Renewed leases shall be filed with the bureau of planning.
Lapse of a required lease agreement shall terminate the special administrative permit
for shared parking.
3. For all uses located in the reduced parking zone: The director of the bureau of planning is authorized to receive and
decide requests for a reduction of the required on-site parking, to a maximum reduction of 100 percent of the regular onsite parking requirements given in this section, based upon consideration of such factors as adequacy of the existing pedestrian infrastructure, age of the
structure, urban design features of the structure, local pedestrian accessibility and connectivity, and proposed use for
the site.
4. For office uses minimum requirements unless otherwise stated:
a) All developments shall reserve and designate at least five percent of the employee parking spaces Carpool Only. Carpool spaces shall be used only by carpool vehicles in which at least two of the persons are employees or tenants of the building. Such spaces shall be located near the building's employee
entrance or other preferable locations within the employee parking areas as approved by the director of
the bureau of traffic and transportation.
b) All new parking structures shall be built to accommodate vanpool access.
The minimum ceiling height for vanpools is eight feet two inches.
5. For residential uses: See Table l, Land Use Intensity Ratios, for minimum parking requirements under appropriate FAR for the development.
6. For non-residential uses minimum requirements unless otherwise stated:
a. Banks, savings and loan institutions, and the like: One space for each 200 square feet of floor area.
b. Business colleges, trade schools, conservatories, dancing schools, and the like: One space for each 200 square feet of floor area.
c. Child care centers, day care centers, prekindergartens, play and other
special schools or day care centers for young children: One space per 600 square feet of floor area. In addition to providing off-street parking, such establishments shall provide safe and convenient facilities for loading and unloading children, as approved by the director, bureau of traffic and transportation.
d. Clubs, lodges, and commercial recreational establishments: One space for each 200 square feet of floor area.
e. Dormitories: No parking requirements.
f. Eating and drinking establishments, including accessory outdoor dining covered with a permanent structure:
i. Within Subareas 1, 2, and 3:
One parking space for each 200 square feet of floor area.
ii. Within Subareas 4-10: One parking space for each 100 square feet of floor area.
g. Fraternities, sororities: One space for two beds plus one space for each 200 square feet of floor area designated or occupied other than for sleeping purposes,
h. Hotels and motels: One space per rental unit plus 1/2 space per employee; one space per 100 square feet of restaurant/lounge gross leasable area (GLA); one space per 300 square feet of other convention facilities (GLA).
i. Nursing homes, convalescent homes, and similar care facilities: One space for four beds.
j. Office uses: No minimum. A maximum of 2.50 spaces for each 1,000 square feet of floor area. Parking during off-peak hours (after 6:00 p.m.) may be shared for other uses.
k. Photocopying shops: One space for each 200 square feet of floor area.
l. Schools, colleges, churches, recreation or community centers and other places of assembly. One space for each four fixed seats (with 18 inches if bench length counted as one seat or one space for each 35 square feet of enclosed floor area for the accommodation of movable seats in the largest assembly room, whichever is greater, plus the following:
i. Public or private elementary or middle school: Two spaces for each classroom.
ii. High school: Four spaces for each classroom.
iii. Colleges and universities: Eight spaces for each classroom.
m. For all other non-residential uses:
One parking space for each 600 square feet of floor area shall be provided on the site.
n. Shelter: One parking space for each on duty staff member, whether paid or unpaid. In addition to staff parking, a space of sufficient size is required for each van, bus or other
vehicle used by the facility and one additional parking space shall be provided for each 2,000 square feet of the facility.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2009-24(08-O-1251), § 2W(3), 6-9-09) Sec. 16-18U.025. Minimum bicycle parking requirements.
See section 16-28.014(6), Bicycle parking requirements.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2019-09(18-O-1581), § 12, 1-31-19) Sec. 16-18U.026. Pedestrian bridges and tunnels.
With the exception of pedestrian bridges that connect Subarea 10 to the West End MARTA Rail Station, pedestrian bridges and tunnels are prohibited when located above or below public streets, private streets which function as public streets connecting two other public streets, or other public rights-of-way.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.027. Zero-lot-line development.
Except in Subarea 7, zero-lot-line subdivision is permitted for residential uses provided a minimum of 1,000 square feet in lot area is provided. The additional requirements of section 16-28.007 shall also apply.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.028. Specific regulations for Subarea 1—Village Center
(Reserved).
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.029. Specific regulations for Subarea 2—Commercial
core (Reserved).
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.030. Specific regulations for Subarea 3—RDA corridor.
1. Except where it is marked otherwise in Table SPI-21 Historic West End/Adair Park Permitted Uses, no single use in this subarea shall occupy more than 15,000 square feet of floor space. This restriction shall apply to individual uses only, and shall not by itself restrict the number of uses permissible on a single lot, nor restrict the overall floor area allowed on a single lot.
2. For ground floor commercial uses, when the finished floor elevation is located at the sidewalk, solid bulkhead walls shall be placed under all windows to a height of between 15 and 25 inches above the sidewalk.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.031. Specific regulations for Subarea 4—Neighborhood
commercial (Reserved).
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.032. Specific regulations for Subarea 5—Village center
residential.
1. All non-residential permitted uses listed in Table SPI-21 Historic West End/Adair Park - Permitted Uses shall be restricted in floor area to a maximum of 20 percent of the total development, shall be located within a building that contains street frontage and shall be located on the street-level floor only. No occupancy permit for such uses shall be issued until a minimum of 50 percent of the total dwelling units are occupied.
2. Upon site redevelopment, Evans Street shall be extended to reconnect to Oglethorpe Street, and said street shall function as a public street.
3. Upon site redevelopment, Victoria Place shall be extended to Lee Street, and the extension shall function as a public street.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.033. Specific regulations for Subarea 6—Medium
density residential.
All non-residential permitted uses listed in Table SPI-21 Historic West End/Adair Park - Permitted Uses shall be restricted in floor area to a maximum of five percent of the total development, shall be located within a building that contains street frontage and shall be located on the street-level floor only. No occupancy permit for such uses shall be issued until a minimum of 50 percent of the total dwelling units are occupied.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.034. Specific regulations for Subarea 7—Smaller lot
single-family (Reserved).
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.035. Specific regulations for Subarea 8—Institutional/
AUC.
Uses in the following categories, as shown in Table SPl-21 Historic West End/Adair Park - Permitted Uses shall only be permitted along designated Storefront Streets: Retail Goods and Services, Entertainment.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05) Sec. 16-18U.036. Specific regulations for Subarea 9—Adair Park live/
work.
Large screen video display (LSVD), as defined in section 16-28A.004, shall be permitted within Subarea 9-Adair Park live/work so long as the sign meets the following requirements:
a. No LSVD sign shall cause glare or impair the vision of the driver of any motor
vehicle or to otherwise interfere with the safe operation of a motor vehicle;
b. All LSVD signs within the district shall be within 300 feet of the right-of-way of Interstate 20 and shall be within 1,000
feet of any road with an access ramp to Interstate 20.
c. No LSVD sign shall be located on a lot less than 1.5 acres in size;
d. No LSVD sign shall be located within 10 feet of any property line;
e. No LSVD sign larger than 300 square feet shall be constructed within 1,000 feet of an existing LSVD sign larger than 300 square feet as measured in a straight line from the nearest edge of the existing LSVD sign;
f. Any LSVD sign with faces converging into a V shape shall enclose the ends of the faces;
g. No LSVD sign shall be located within 1,000 feet of any property zoned R-l, R-2,
R-2A, R-2B, R-3, R-3A, R-4, R-4A, R-4B,
R-5, R-G, R-LC as measured in a straight line from the boundaries of any properties zoned under these zoning classifications to the nearest edge of the sign;
h. The sign face of the LSVD sign shall not be greater than 175 feet above existing
grade;
i. No LSVD signs shall have more than two video display faces;
j. No LSVD sign shall exceed 2,000 square feet in video display facing per side;
k. No LSVD sign shall be located within 1,000 feet of the boundaries of a City of Atlanta park in existence as of June 17, 2019 pursuant to the attached list of
parks in Attachment A of this Ordinance, as measured in a straight line from the
nearest boundary of a City of Atlanta park to the nearest edge of the sign;
l. All LSVD signs shall come equipped with a light sensing device that automatically adjusts the brightness in direct correlation with ambient light conditions;
m. The brightness of light emitted from the LSVD sign shall not exceed 0.3-foot
candles over ambient light levels measured at a distance of 350 feet;
n. All permits for LSVD signs shall be issued pursuant to the provisions of 16-28A.013 in lieu of the requirements under 16-18U.004;
o. The content displayed on the LSVD sign shall be limited to advertising related to businesses lawfully operating on the
property where the sign is located; and
p. Should any provision of this section conflict with the regulations of Chapter 28A of the City of Atlanta Zoning
Ordinance (Sign Ordinance), these regulations shall control.
(Ord. No. 2005-51, § 1(Att. A), 8-22-05; Ord. No.
2019-35(19-O-1056), § 2, 6-26-19) Sec. 16-18U.037. Specific regulations for Subarea 10—Candler
District (Reserved).
(Ord. No. 2005-51, § 1(Att. A), 8-22-05)
CHAPTER 18V. SPI-22 MEMORIAL
DRIVE/OAKLAND CEMETERY SPECIAL
PUBLIC INTEREST DISTRICT
REGULATIONS
Sec. 16-18V.001. Scope of provisions.
The regulations set forth in this chapter, or set forth elsewhere in this part when referred to in this chapter, are the regulations in the SPI-22 Memorial Drive/Oakland Cemetery District. These regulations shall supplant existing districts or portions of existing districts as shown on the attached map referenced in Section 16-18V.003, except that all existing categories of historic protection designated pursuant to Chapter 20 of Part 16 shall continue in full force and effect and said existing historic protection regulations shall be overlaid upon, and shall be imposed in addition to, the regulations set forth in this Chapter.
Whenever the following regulations are at variance with said existing historic protection regulations, the historic protection regulations shall apply. Whenever the following regulations conflict with provisions of Part 16 other than historic protection regulations and Sections 16-18V.007, 16-18V.014 and 16-18V.019, the more stringent regulations shall apply.
The regulations set forth in Section 16-18V.001 through and including Section 16-18V.021 shall apply to all properties located within the SPI-22 Memorial Drive/Oakland Cemetery Special Public Interest District, including all subareas within the District. The remaining regulations set forth in Section 16-18V.022 through Section 16-18V.026 shall apply only to the subareas identified therein.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.002. Statement of intent.
The intent of the council in establishing SPI-22 as a zoning district is as follows:
1. Implement provisions of the Comprehensive Development Plan incorporating certain recommendations contained in studies of this area, including the comprehensive study known as the Memorial Drive/MLK Jr. Drive Area
Revitalization Study as adopted by the City of Atlanta;
2. Encourage a compatible mixture of residential, commercial, entertainment, cultural and recreational uses;
3. Encourage the development of mixed-use pedestrian oriented building forms and
uses within the area;
4. Promote the revitalization of pedestrianoriented shopping and entertainment streets through sidewalk-level oriented
buildings and uses;
5. Encourage the development of medium and high intensity housing that provides a range of housing opportunities for
citizens within the district;
6. Create a diversified 24-hour urban environment where people can live, work, shop, meet and play;
7. Preserve existing historic single-family neighborhoods from uses and building
forms which are incompatible with their scale, character and needs by providing a location for needed neighborhood commercial and retail uses;
8. Preserve historic buildings and sites within the district by facilitating adaptive re-use and rehabilitation;
9. Enhance and protect Oakland Cemetery as a historic and cultural resource;
10. Encourage infill development within traditional commercial areas that include proportionately significant residential
uses;
11. Promote public safety through the provision of pedestrian-oriented street-level uses, sufficient sidewalk widths, adequate visibility and primary pedestrian access from buildings to sidewalks to create a
sense of activity and liveliness along their faç
12. Facilitate safe, pleasant, and convenient sidewalk level pedestrian circulation and bike usage that minimizes conflict with
vehicles;
13. Maximize opportunities for sufficient, safe and accessible pedestrian amenities
including parks, plazas, greenways and public art for active and passive enjoyment;
14. Improve the aesthetics of street and built environments;
15. Enhance the efficient utilization of parking facilities by encouraging shared parking and alternative modes of transportation;
16. Provide accessible and sufficient parking in an unobtrusive manner;
17. Encourage the use of MARTA and other public transit facilities;
18. Encourage opportunities for economic development, both residential and commercial, where there is a planned relationship between the transportation system and development;
19. Provide connections between the Capitol Gateway, Grant Park, Cabbagetown and
Reynoldstown communities and between those communities and adjacent areas including, Downtown and the State Capitol area, DeKalb Avenue, the Old 4th Ward neighborhood, and Zoo Atlanta areas.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V-003. Boundaries of district
established.
The boundaries of the SPI-22 Memorial Drive/ Oakland Cemetery Special Public Interest District are shown on map Attachment B which by this reference is incorporated into and made a part of this chapter and this part. The Memorial Drive/ Oakland Cemetery Special Public Interest District is divided into five subareas as shown on said map Attachment B and are described as follows:
Subarea 1—MLK Lofts (including the King Memorial Transit Station Area) Subarea 2—Capitol-Oakland Corridor Subarea 3—Capitol Gateway Subarea 4—Grant Park North Subarea 5—Memorial Green (Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.004. Application procedures.
A Special Administrative Permit (SAP) application and a specified number of copies each of a site plan, landscape plan and elevation drawings of each exterior façade shall be submitted, as applicable, and approved by the Director of the Bureau of Planning prior to an applicant filing for a building permit. All exterior demolition, new construction (including additions to existing buildings), expansions of existing outdoor dining, outdoor dining within required sidewalk areas, or any construction which results in increased lot coverage, modification of the building footprint, or modification of building façades that alters the configuration of openings, shall be subject to said site plan and building elevation approval.
Before making an application for a special administrative permit, a pre-application conference between the applicant and the Director of the Bureau of Planning or the Director's designee is required to discuss the application and relevant requirements of these regulations. Said preapplication conference shall be held within 14 days of the date of the request by the applicant, unless a longer period is mutually agreed upon.
All applications for a SAP shall be processed in accordance with the standards and procedures applicable to said SAP applications contained in Chapter 25 of Part 16 except as otherwise modified by this Chapter 18.
Where regulations may require the approval of a SAP for other purposes so specified, processing by the Director of the Bureau of Planning shall, without additional application, include consideration of other special administrative permits. Where such regulations require special exception or special use permit action, the special administrative permit for building permit purposes shall not be issued until the necessary approval has been obtained for special exception or special use permit.
The Director of the Bureau of Planning may exempt certain classes of applications for special administrative permits from detailed review requirements as set forth upon written findings that generally within these districts, the actions proposed are of such a character or of such a scale as to make detailed reviews and approval by the Planning Director unnecessary. Where applications for special administrative permits are determined by reference to such findings to be thus exempted, the permit shall be issued if otherwise lawful.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06; Ord. No.
2018-11(18-O-1023), § 9.D, 5-16-18) Sec. 16-18V.005. Use regulations.
1. See SPI-22 Memorial Drive/Oakland Cemetery: Use Table for permitted principal uses and special permits. Any principal use not specifically listed in the table below is prohibited.
2. Permitted Principal Uses:
a. A building or premises shall be used only for the principal purposes as indicated
with a P in SPI-22 Memorial Drive/ Oakland Cemetery: Use Table.
b. For the purposes of this Chapter, uses at sidewalk-level in what would otherwise
be classified as an independent primary parking structure or lot shall not constitute principal uses and shall not be permitted.
c. No use or manner of operation shall be permitted which is obnoxious or offensive by reason of odor, smoke, noise, glare,
fumes, gas, vibration, unusual danger of fire or explosion, emission of particulate matter, or interference with radio or
television communication, or is otherwise incompatible with the character of the
district and its relation to adjoining districts.
d. Outdoor sales or displays are permissible only by special permit as set forth below.
3. Permitted Accessory Uses and Structures:
Accessory uses and structures permitted within this district shall include those customarily accessory and clearly incidental to permitted principal uses and structures and specifically includes clubhouses, pools, other recreation amenities, parking to serve authorized residential and nonresidential uses within the district, subject to the restrictions contained elsewhere in this chapter, and electric vehicle charging stations equipped with Level 1, Level 2, and/or DC Fast Charge EVSE.
4. Special Permits: The following uses are permissible only by special permits of the type indicated subject to limitations and requirements set herein or elsewhere in this part, and subject to the applicable procedures and requirements set forth in Part 16, Chapter 25. SPECIAL
PERMITS.
a. Special use permits shall be required as indicated with "SUP" in the SPI-22 Memorial Drive/Oakland Cemetery: Use Table.
b. Special administrative permits shall be required as indicated with "SAP" in the
SPI-22 Memorial Drive/Oakland Cemetery: Use Table.
c. Special exceptions: None.
SPI-22 MEMORIAL DRIVE/OAKLAND CEMETERY: USE TABLE
SUBAREAS
P = Permitted SAP = Special Administrative Permit SUP = Special Use Permit X = Not Permitted
MLK LOFTS
1
CAPITOLOAKLAND
CORRIDOR
2
CAPITOL
GATEWAY
3
GRANT PARK
NORTH
4
MEMORIAL
GREEN
5 Commercial/Retail Bakeries and catering establishments P P P P - Eating and drinking establishments limited to 10,000 sq. ft. (Drive-through facilities are not permitted)
P P P P -
Grocery stores limited to 35,000 sq. ft. P X P P - Laundry and dry cleaning establishments;
laundry and dry cleaning establishments where equipment is operated by customers
P P P P -
Photocoping, printing or blueprinting shops P P P P - Professional or personal service establishments including barber shops, beauty shops, manicure shops and similar, but not hiring halls
P P P P -
Retail establishments (not including auto sales or rental) with the following size limitations:
•Subarea 1: a maximum size of 20,000 sq.
ft.
•Subareas 2, 3, and 4: a maximum size of 20,000 sq. ft. when entirely within 200 feet of the right-of-way of arterial or collector streets, and 10,000 sq. ft. in other areas.
P P P P -
SPI-22 MEMORIAL DRIVE/OAKLAND CEMETERY: USE TABLE
SUBAREAS
P = Permitted SAP = Special Administrative Permit SUP = Special Use Permit X = Not Permitted
MLK LOFTS
1
CAPITOLOAKLAND
CORRIDOR
2
CAPITOL
GATEWAY
3
GRANT PARK
NORTH
4
MEMORIAL
GREEN
5 Sales and repair of office equipment or installations; home appliances, plumbing, air conditioners, lawnmowers, bicycles, clocks and watches, shoes, leather goods and
similar household goods within enclosed buildings.
P P P P -
Sales and leasing agencies for new and used bicycles and mopeds.
(Automobile sales and leasing agencies are not permitted)
P P P P -
Small discount variety stores, provided that no small discount variety store may be
located within 5,280 feet of another small discount variety store.
P P P P -
Tailoring, custom dressmaking, millinery and similar establishments P X P P -
Education/Child Care Business or commercial schools P X P P - Child care centers, kindergartens and
special schools P X P P - Public schools and private schools having similar academic curricula and institutions of higher learning, including colleges and universities
P P P P -
Institutional Banks, savings and loan associations, and similar financial institutions, subject to Section 16-18V.015(7)
P P P P -
Churches, synagogues, temples, and other religious worship facilities SUP SUP SUP SUP - Community service facilities and similar establishments P P P P -
Museums, art galleries, libraries, and similar cultural facilities P P P P - Manufacturing Manufacturing, wholesaling, repairing, assembly, processing, preparation, packaging or treatments of articles, foods, components, products, clothing, machines and appliances and the like uses, where character of operations, emissions and byproducts do not create adverse effects beyond the boundaries of the property. The use of heavy drop hammers, punch presses or other machinery; or processing methods creating excessive noise or vibration is prohibited.
In Subarea 1: an SUP is required if greater than 15,000 sq. ft.
P/SUP X X SUP -
Medical/Health
SPI-22 MEMORIAL DRIVE/OAKLAND CEMETERY: USE TABLE
SUBAREAS
P = Permitted SAP = Special Administrative Permit SUP = Special Use Permit X = Not Permitted
MLK LOFTS
1
CAPITOLOAKLAND
CORRIDOR
2
CAPITOL
GATEWAY
3
GRANT PARK
NORTH
4
MEMORIAL
GREEN
5 Clinics (including veterinary), laboratories, and similar uses, but not blood donor stations except at hospitals. Veterinary clinics shall be located within soundproof buildings when located within 300 feet of any
residential use.
P X P P -
Hospitals SUP X SUP SUP - Nursing homes, personal care homes, assisted living facilities, and rehabilitation centers.
SUP X SUP SUP -
Office Offices P X P P - Recreation/Entertainment Civic, service, garden, neighborhood or private club or lodges P P P P - Commercial recreation establishments, including bowling alleys, theatres, convention halls, places of assembly, and similar uses with primary activities conducted
within fully enclosed buildings
P P P P -
Outdoor amusement enterprises, exhibits, entertainments, meetings, displays or sales areas, or outdoor areas for religious ceremonies Less than 90 days duration SAP SAP SAP SAP - 90 days or more duration SUP SUP SUP SUP - Party houses provided that the use shall be prohibited within 150 feet of a property zoned R-1, R-2, R-2A, R-2B, R-3, R-3A, R-4, R-4A, R-4B, R-5, RG, MR or a property used for residential purposes measured from
property line to property line
SAP SAP SAP SAP SAP
Sports arenas and complexes SUP X SUP x - Residential Dwellings/Lodgings
Dormitories, fraternities and sororities associated with an institution of higher learning
P X P P -
Hotels and motels SUP SUP SUP SUP - Multi-family dwellings P x P P - Shelter SUP SUP SUP SUP Short-term rentals, subject to the regulations in Atlanta City Code section 20-1001. P P P P P Single-family and two-family dwellings
•In Subarea 4: only permitted as a principal use when adjacent to Woodward Avenue or
McDonald Street or Kelly Street and not adjacent to Memorial Drive.
x x x X/P - Single room occupancy residences SUP x SUP SUP - Supportive housing P X P P -
Transportation/Parking Helicopter landing facilities or pickup or delivery stations SUP X SUP SUP -
SPI-22 MEMORIAL DRIVE/OAKLAND CEMETERY: USE TABLE
SUBAREAS
P = Permitted SAP = Special Administrative Permit SUP = Special Use Permit X = Not Permitted
MLK LOFTS
1
CAPITOLOAKLAND
CORRIDOR
2
CAPITOL
GATEWAY
3
GRANT PARK
NORTH
4
MEMORIAL
GREEN
5 Structures and uses required for the operation of MARTA or a public utility but not including uses involving storage, train yards, warehousing, switching or maintenance shop as the primary purpose.
P P P P -
Utilities Broadcasting towers, line-ofsight relay devices for telephonic, radio or television communications subject to Transitional Height
Planes (Section 16-18V.009) Less than 70 feet in height, and an alternative design mounting structures as contemplated by Sec.
16-25.002 (3)(h)(iv)(i)
SAP SAP SAP SAP -
Greater than 70 feet in height, except alternative design mounting structures as contemplated by Sec.
16-25.002 (3)(h)(iv)(i)
SUP SUP SUP SUP -
Data centers, except where any part of the property is within 2,640 feet of a highcapacity transit stop, as referenced in City Code Section 16-28.014(14).
SUP X SUP SUP -
Digital industry switchboards, relay equipment, and associated power generators as principal uses. Data centers are excluded from this use in this
district.
SUP X SUP SUP -
Other Drive-in and drive-through facilities, subject to Section 16-18V.015(7) P P P P -
Farmers' market SAP SAP SAP SAP SAP Market gardens P P P P - Urban gardens P P P P - (Ord. No. 2006-96, § 1(Att. A), 12-6-06; Ord. No. 2009-24(08-O-1251), §§ 2X, 2X(2), 6-9-09; Ord. No.
2011-39(10-O-1773), § 3AC, 9-15-11; Ord. No. 2014-53(14-O-1278), § 2(Attach. B), 12-10-14; Ord. No.
2014-22(14-O-1092), § 2-HH, 6-11-14; Ord. No. 2019-66(19-O-1504), § 19, 12-11-19; Ord. No.
2020-23(20-O-1229), § 2, 4-29-20; Ord. No. 2020-58(19-O-1393), § 46, 10-28-20; Ord. No. 2021-60(21- O-0682), § 42, 12-15-21; Ord. No. 2024-36(24-O-1222), § 10, 9-4-24) Sec. 16-18V.006. Redevelopment requirements.
The provisions in Part 16, Chapter 24, Nonconformities shall apply, with the exception of those structures located in Subarea 1—MLK Lofts that were built prior to the year 1955 and that are damaged or demolished by any means may be repaired or rebuilt to their previous building footprint and use if not more than 30 months after the effective date of damage or demolition. Any structure located in Subarea 1 falling under this exception shall be exempt from all applicable requirements of this district except for Section 16-18V.009, Sidewalks.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.007. Transitional uses, height and yards.
1. Adjoining Lot with Same Frontage: Where a lot in this district abuts a lot in any R-1 through R-5, R-G, MR, RLC, or PD-H district at the side along the same street frontage, and without an intervening street or railroad rightof-way, such lot within this district or the first 100 feet on such lot if it is wider than 100 feet, shall not be used for any drive-through service window or drive-in facility even where otherwise specifically authorized.
2. Transitional height limit: Maximum height where any subarea of this district adjoins residential districts R-1 through R-5, RG-1, RG-2, MR-1, MR-2, RLC, or PD-H without an intervening street or railroad right-of-way shall be provided as follows: (See Diagram 1a)
a. Any portion of a building or structure which is less than 40 feet from the buildable area adjacent to said residential districts shall be a maximum of 35 feet in height;
b. Any portion of a building or structure which is 40 feet or greater from the buildable area adjacent to said residential districts shall be the maximum height as indicated on the SPI-22 Memorial Drive/
Oakland Cemetery: Development Controls Table.
3. Transitional yards: Any mixed-use or multifamily development, with the exception of attached single family dwellings with no unit above or below, and where any subarea of this district adjoins an R-1 through R-5, RG-1, RG-2, MR-1, MR-2, RLC, or PD-H without an intervening street or railroad right-of-way shall provide permanent opaque walls six feet in height and maintained in sightly condition and shall provide either:
a. A minimum of ten feet which shall not be used for the purpose of parking, paving, loading, servicing or any other activity with the exception of private alleys or
drives. Where not used for the purpose of private alleys or drives such yards shall be planted as approved by the city arborist and maintained as a landscaped strip;
b. Where an existing and publicly recorded alley shall be used to serve accessory
parking or loading areas: the required wall shall be located between the building and the alley provided that it does not
obstruct visibility at ingress and egress points into said parking or loading areas.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.008. Development controls.
See SPI-22 Memorial Drive/Oakland Cemetery: Development Controls Table for bulk limitations, building coverage, open space requirements, yard requirements, height requirements and minimum lot requirements subject to subsections 1. through 6. below.
1. For purposes of this Chapter, and notwithstanding the provisions of subsection 16- 29.001(24), mixed-use development is defined as any development which contains as principal uses both residential and
non-residential uses on the same development site, and in which both of such uses are at least 20 percent of the total floor area, excluding accessory uses. When either the total non-residential or residential floor area of a development is less than 20 percent of the total floor area, minimum Residential Useable Open Space
Requirements (UOSR) or Public Space Requirements (PSR) shall not apply to said floor area.
2. Residential uses, including portions of mixed-use developments, may utilize net
area of a regular lot (NLA) or gross area of a regular lot (GLA) when calculating maximum permitted residential floor area, provided UOSR is calculated using the
corresponding lot area. Non-residential uses shall utilize NLA.
3. Transit station area density bonus: Developments located within the King Memorial Transit Station Area shall be permitted a floor area ratio bonus as indicated on the SPI-22 Memorial Drive/Oakland
Cemetery: Development Controls Table.
4. Subarea 4—Grant Park North Residential Concurrency Requirement:
a. For new developments: No certificate of occupancy shall be issued for any non-residential uses until such time as the certificate of occupancy has been issued for an equal or greater amount of residential use which shall be located directly above said nonresidential uses within the same building.
b. Where additions to primary structures or the construction of new buildings exceed 2,000 square feet: No certificate of occupancy shall be issued for any non-residential uses until such time as the certificate of
occupancy has been issued for an equal or greater amount of residential use on the same site.
c. Where additions to primary structures or the construction of new buildings is to be 2,000 square feet or less:
The residential concurrency requirements above shall not apply.
5. There are no total open space requirements (TOSR). The following areas shall be counted towards USOR or PSR:
a. The entire covered or uncovered horizontal area of residential balconies which are enclosed on three sides
may count towards UOSR.
b. The uncovered horizontal area of rooftop stormwater treatment gardens may count towards UOSR or PSR.
c. The required sidewalk and supplemental zone may count toward UOSR or PSR when in conformance with
the standards and requirements of Section 16-18V.009 and 16-18V.010 according to the following criteria:
i. When the net lot is utilized only the portion of the public sidewalk within the net lot may be counted towards UOSR or
PSR.
ii. When the gross lot is utilized portions of the public sidewalk located within the right-of-way may be counted toward UOSR or PSR.
d. The total area of new on-street parking may count towards UOSR or PSR provided the following criteria
are met:
i. No on-street parking currently exists in the public right-ofway adjacent to the project area for which credit is sought;
ii. The new on-street parking is located where there is no existing street travel lane;
iii. Curb extensions are provided at street intersections where applicable; and iv. All other sidewalk requirements of this Chapter are met.
6. Zero-lot-line subdivision is permitted for residential uses provided the minimum lot size established in the
SPI-22 Memorial Drive/Oakland Cemetery: Development Controls Table is provided. The additional requirements of section 16-28.007 shall also apply.
SPI-22 MEMORIAL DRIVE/OAKLAND CEMETERY: DEVELOPMENT CONTROLS TABLE
SUBAREAS
MLK LOFTS
1
CAPITOLOAKLAND
CORRIDOR
2
CAPITOL
GATEWAY
3
GRANT PARK
NORTH
4
MEMORIAL
GREEN
5
BULK LIMITATIONS
Non-residential Maximum FAR1 2.0 2.0 1.0 1.02 - Residential Maximum FAR1 4.0 None 2.5 2.52 - Maximum Achievable Combined Base FAR1 6.0 2.0 3.0 3.02 - Bonus Residential Maximum FAR1 within
designated King Memorial Transit Station Area (as identified in Map Attachment B)
2.0 - - - - Maximum Achievable Combined Bonus FAR1 8.0 - - - -
BUILDING COVERAGE
Maximum Building Coverage, as percent of
NLA 85% 85% 85% 85% -
MINIMUM OPEN SPACE REQUIREMENTS3
Non-Residential Public Space Requirement
(PSR)4 10% 10% 10% 10% -
SPI-22 MEMORIAL DRIVE/OAKLAND CEMETERY: DEVELOPMENT CONTROLS TABLE
SUBAREAS
MLK LOFTS
1
CAPITOLOAKLAND
CORRIDOR
2
CAPITOL
GATEWAY
3
GRANT PARK
NORTH
4
MEMORIAL
GREEN
5 Residential Usable Open Space Requirements (UOSR)4 shall be equal to the lesser of
15% floor area or 80% lot area 15% floor area or 80% lot area 15% floor area or 80% lot area 15% floor area or 80% lot area 15% floor area or 80% lot area Minimum Yard Requirements (not adjacent to street)5 Side & Minimum Side & Rear Yard with no
windows placed on the portion of a facade adjacent to such yard6
None None None None - Minimum Side & Rear Yard with windows placed on the portion of a facade adjacent to such yard6, 7
3 ft. or more 3 ft. or more 3 ft. or more 3 ft. or more - Minimum Transitional Yard6 10 ft. 10 ft. 10 ft. 10 ft. - Height Requirements
Minimum Building Facade Height adjacent to Memorial Drive8 n/a 35 ft. 35 ft. 35 ft. - Minimum Building Facade Height adjacent to all other streets (not Memorial Drive) 28 ft. 28 ft. 24 ft. 24 ft. - Maximum Building Height (subject to transitional height limits) 200 ft. or 76
ft.9 64 ft. 66 ft. or 225 ft.10 66 ft. or 58 ft. or 50 ft. or 35 ft.11 -
MINIMUM LOT REQUIREMENTS
Minimum Street Frontage nonresidential uses None None None 50 ft - residential uses 20 ft. 20 ft. 20 ft. 50 ft. - Minimum Lot Size nonresidential uses None None None 7,500 sq. ft. - residential uses 1,000 sq. ft. 1,000 sq. ft. 1,000 sq. ft. 7,500 sq. ft. -
1. FAR shall be multiplied by NLA or GLA to determine maximum permitted floor area, subject to Section 16-18V.008(2) above.
2. See Section 16-18V.008(4).
3. For mixed-use developments, except as authorized in Section 16-18V.008(1), both residential and non-residential requirements shall be met separately.
4. See Section 16-28.012 for definition and measurements.
5. Sidewalk and supplemental zone requirements shall be the minimum setback requirements for yards adjacent to streets.
6. Subject to transitional yard requirements per Section 16-18V.007(3).
7. Subject to Building Code requirements. See Diagram 1b.
8. Subject to transitional height limit per Section 16-18V.007(2). See also Section 16-18V.011. See Diagram 1a. Note: Locations for Maximum Building Height are to be measured at ground-level from the property line adjacent to said street(s).
9. MLK Lofts Subarea #1 Maximum Heights:
a) 200 feet in height when located greater than 200 feet adjacent to either Martin Luther King Jr. Drive or Oakland Avenue.
b) All other areas: 76 feet in height.
10. Capitol Gateway Subarea #3 Maximum Heights:
a) 225 feet in height when located greater than 50 feet adjacent to Memorial Drive and west of Fraser Street.
b) All other areas: 66 feet in height.
11. Grant Park North Subarea #4 Maximum Heights:
a) 66 feet in height when located equal to or less than 200 feet adjacent to Memorial Drive and east of Cherokee Avenue.
b) 66 feet in height when located equal to or less than 200 feet measured adjacent to Memorial Drive and equal to or greater than 150 feet west of Harden Street.
c) 58 feet in height when located equal to or less than 200 feet adjacent to Memorial Drive at all other areas.
d) 50 feet in height when located greater than 200 feet measured at ground-level from the property line adjacent to Memorial Drive and adjacent to either Hill Street or Cherokee Avenue or Boulevard.
e) All other areas: 35 feet in height.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) _________________________________________________________________________________________________ Sec. 16-18V.009. Sidewalks.
Public sidewalks shall be located along all streets and shall have the widths identified in the SPI-22 Memorial Drive/Oakland Cemetery: Sidewalk and Supplemental Zone Table.
1. Street furniture and tree planting zone: is the portion of a sidewalk located between the sidewalk clear zone and the curb that is reserved for the placement of street
trees and street furniture including utility poles, waste receptacles, fire hydrants, traffic signs, traffic control boxes, newspaper vending boxes, transit shelters, bicycle racks, benches and similar elements in a manner that does not obstruct pedestrian access or motorist visibility. See Diagram 2. The street furniture and tree planting zone shall have the width requirements specified in the SPI-22 Memorial Drive/Oakland Cemetery: Sidewalk and
Supplemental Zone Table.
2. Sidewalk clear zone: is the portion of the sidewalk that is continuous hardscape
(subject to subsection 16-18V.025(1), and unobstructed by any permanent objects
for a minimum height of eight feet reserved for pedestrian circulation and passage, except as authorized in subsection 16-18V.009(3) and subsection 16-
18V.009(4). See Diagram 2. No fixed elements, including traffic control boxes and other utility structures shall be placed above ground in the clear zone. The clear zone shall have a consistent cross-slope not exceeding two percent. The sidewalk
clear zone shall have the width requirements specified in the SPI-22 Memorial Drive /Oakland Cemetery: Sidewalk and
Supplemental Zone Table except where property within these districts abuts an R, R-G, MR, PD-H, or LW district without an intervening street or railroad right-ofway, the sidewalk area within 20 feet of such districts shall taper as necessary to provide a smooth transition to the existing R, R-G, MR, PD-H, LW or Oakland Cemetery Landmark district sidewalk. In
the event that the abutting R, R-G, MR, PD-H, LW or Oakland Cemetery Land- mark district has no existing sidewalk, the sidewalk shall taper to a width of six feet.
3. Outdoor dining within required sidewalk:
a. Buildings existing prior to the adoption of this ordinance with adjacent sidewalks that do not meet the requirements of this Chapter, may have outdoor dining that encroaches into
the existing sidewalk provided the following criteria are met:
i. Shall have a minimum of six feet of unobstructed sidewalk area adjacent to the curb when located adjacent to local streets;
ii. Shall have a minimum of eight feet of unobstructed sidewalk area adjacent to the curb when located adjacent to arterial or collector streets.
b. New developments located adjacent to local streets may have outdoor dining that encroaches into the sidewalk clear zone when a minimum of six feet of unobstructed clear zone is
provided.
c. Outdoor dining may be separated from the sidewalk only with movable planters, fencing or similar nonfixed barriers provided they do not exceed a height of 36 inches including any plant material.
d. At such time as the outdoor dining use is discontinued, sidewalks shall comply with all requirements of this Chapter.
e. No permanent structure or ornamentation shall be located within the encroachment area and no element
shall be attached to the sidewalk in any way.
4. Encroachment of steps, stoops and landscaping: Along local streets only, new developments with sidewalk-level residential units may have steps, stoops and landscaping encroach into the sidewalk
clear zone when a minimum of six feet of unobstructed clear zone is provided and
said area is not located within the public right-of-way.
5. Street trees: Are required as indicated in SPI-22 Memorial Drive/Oakland Cemetery:
Sidewalk and Supplemental Zone Table.
Street trees shall be planted a maximum of 30 feet on center within the street furniture and tree planting zone and spaced equal distance apart. All newly planted
trees shall have a minimum of three inches in caliper measured 36 inches above
ground, a minimum of 12 feet in height, a minimum mature height of 40 feet, and
limbed up to a minimum height of seven feet. Trees shall have a minimum planting area of 40 square feet. Tree-planting areas shall be planted with evergreen
ground cover such as mondo grass or liriope spicata, except where tree grates are installed. All plantings, planting replacement and planting removal shall be approved by the City Arborist. The area
between required plantings shall either be planted with evergreen ground cover such as mondo grass or liriope spicata or shall be paved as approved by the Director of Planning.
6. Tree grates: Are not required. Where tree grates are installed they shall be a minimum size of four feet by eight feet, shall be a type specified by the Director of
Planning in accordance with uniform design standards utilized by the Director for placement of such objects in the public
right-of-way, and shall be placed within the street furniture and tree planting
zone.
7. Paving materials: All paving within the street furniture and tree planting zone
shall be a type specified by the Director of Planning in accordance with uniform design standards utilized by the Director for placement of such objects in the public
right-of-way.
8. Decorative pedestrian lights: where installed, shall be placed a maximum of 60 feet on center and spaced equidistant between street trees within the street furniture and tree planting zone. See Diagram
4. All said lights shall be Atlanta Type "C" or other as approved by the Director of the Bureau of Planning.
9. Trash receptacles or similar elements: where installed, shall be a type specified by the Director of the Bureau of Planning in
accordance with uniform design standards utilized by the Director for placement of such objects in the public rightof-way and shall be placed within the street furniture and tree planting zone.
10. Visibility at intersections: Nothing shall be erected, placed, planted or allowed to grow in such a manner as to impede
visibility within visibility triangles at street intersections, as measured from the curb, between the heights of two and one-half
feet and eight feet above grade. See subsection 16-28.008(9), visibility at intersections.
11. Overhead utilities: Upon redevelopment of a parcel reasonable efforts shall be
made to place utilities underground or to the rear of structures to allow for unobstructed use of sidewalks.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.010. Supplemental zone.
For purposes of this chapter the Supplemental Zone is defined as the area between any building, including parking deck or any surface parking lot and the back of the required sidewalk, when no intervening building exists. See Diagram 2. Except as otherwise specified below, the square footage contained within a supplemental zone which meets all of the following supplemental zone requirements may be counted towards UOSR or public space requirements (PSR) as indicated in Section 16-18V.008 and Section 16-28.012.
1. The supplemental zone shall have the width requirements specified in the Memorial Drive/Oakland Cemetery: Sidewalk and Supplemental Zone Table.
2. Supplemental zone general requirements:
a. When sidewalk-level residential units are provided, the supplemental zone
shall be landscaped with the exception of terraces, porches, stoops and walkways, which may occupy a maximum of two-thirds of the supplemental zone area.
b. Terraces, porches and stoops shall have a maximum finished floor height of 24 inches above finished-grade, unless existing topographical considerations render this requirement unreasonable, subject to the provisions in subsection 16-25.002(3).
c. The supplemental zone shall be no more than 24 inches above the adjacent public sidewalk for a minimum linear distance of 15 feet from the
nearest edge of the adjacent public sidewalk, unless existing topographical considerations render this requirement unreasonable.
d. Any authorized walls surrounding landscaped and grassed areas shall not exceed a maximum height of 24 inches, except retaining walls, which shall not exceed a maximum height of 36 inches unless existing topographic considerations render this requirement unreasonable.
e. Outdoor dining may be located in the supplemental zone and may be separated from the sidewalk only with movable planters, fencing, or similar barriers provided they do not exceed a height of 36 inches including any plant material.
f. Balconies may be located within the supplemental zone provided they do not encroach more than five feet into a supplemental zone.
g. Retail display windows or cases may project into the required supplemental zone but not cover more than two-thirds of its horizontal area and
have a minimum depth of three feet.
h. Patio decks shall not be permitted within the supplemental zone.
SPI-22 MEMORIAL DRIVE/OAKLAND CEMETERY:
SIDEWALK AND SUPPLEMENTAL ZONE TABLE
Street Furniture and Tree Planting Zone Minimum Width Sidewalk Clear Zone Minimum Width Supplemental Zone Street Trees In Street Furniture and Tree Planting Zone Minimum Width Maximum Width Memorial Drive 5 feet 10 feet 5 feet 25 feet Required Martin Luther King Jr.
Drive (west of Grant St.) 5 feet 10 feet 5 feet 25 feet Required Martin Luther King Jr.
Drive (east of Grant St.) 5 feet 10 feet 15 feet 25 feet Required Biggers Street 5 feet 10 feet None or 5
feet* 20 feet Required Capitol Avenue 5 feet 10 feet 5 feet 25 feet Required Hill Street (south of Martin Luther King Jr. Dr.) 5 feet 10 feet None or 5 feet* 15 feet Required
Hill Street (north of Martin Luther King Jr. Dr.) 4 feet 6 feet None 20 feet Required Grant Street - east side
(north of Martin Luther King Jr. Dr.)
5 feet 10 feet 5 feet 15 feet Required Grant Street - west side (north of Martin Luther King Jr. Dr.)
2 feet 6 feet None 20 feet Required George Street None 6 feet None 20 feet None Cherokee Street 5 feet 10 feet None or 5 feet* 20 feet Required
Boulevard 5 feet 10 feet None or 5 feet* 20 feet Required All other Streets 5 feet 6 feet None or 5 feet* 20 feet Required
* 5 feet minimum required adjacent to sidewalk-level residential use; otherwise no supplemental zone requirement.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.011. Relationship of building to street.
1. The regulations in this section shall apply to all buildings and structures, including parking structures, adjacent to a required sidewalk or provided supplemental zone having a habitable space with a finished floor not more than five feet above or below the adjacent sidewalk. Such floor or floors shall be considered the sidewalk-level.
See Diagrams 3 and 4.
2. Active uses: shall be required within buildings at sidewalk-level along Memorial Drive, Martin Luther King Jr. Drive, Capitol Avenue, Hill Street (south of Martin Luther King, Jr. Drive), Cherokee Avenue, and Boulevard, and along portions of local streets directly adjacent to Oakland Cemetery or a public park, except at ingress and egress points into parking structures or loading areas. For the purposes of this chapter active uses shall be serviced by plumbing, heating, and electricity and are limited to residential, retail, eating and drinking establishments, museum, gallery, office, institutional, auditorium, library, hotel lobby, or cultural facility uses, and shall not include parking, non-residential storage areas, driveway or queuing lanes parallel to the adjacent street.
Minimum active use depths from the street-facing building facade shall be provided as follows:
a. Single-family, two-family or multi-family residential buildings with no residential units located above or below a unit: Minimum depth of ten feet.
b. All other uses (as specified above): Minimum depth of 20 feet. See Diagram 3.
c. When two or more floors meeting the definition of sidewalk-level exist within the same building, this requirement shall only apply to the frontage of each floor located within five vertical feet above or below the grade of the adjacent sidewalk.
See Diagram 4.
3. Minimum building facade height and floor delineation: The street-facing building facade shall rise vertically at the back of the required sidewalk or provided supplemental zone for the minimum building facade height as indicated on the SPI-22 Memorial Drive/Oakland Cemetery Development Controls Table. Building floors shall be delineated above sidewalk-level through windows, belt courses, cornice lines or similar architectural detailing.
4. Minimum sidewalk-level floor to ceiling height: shall be 12 feet for non-residential uses.
See Diagram 3.
5. Minimum building frontage:
a. Building facades shall be built to the back of and predominantly parallel to the required supplemental zone (as applicable) or sidewalk clear zone adjacent to Memorial Drive, Martin Luther King Jr. Drive, Capitol Avenue, Hill Street (south of Martin Luther King Jr. Drive), Cherokee Avenue, and Boulevard, for a minimum of 80 percent of the length of said supplemental or sidewalk clear zone. This shall not be construed as meaning that the building
facade may not be articulated for doors, storefront windows, columns, or similar
architectural features which may be recessed from the back of the required sidewalk a maximum depth of 18 inches from the facade to allow for articulation.
b. Doors may be recessed from the back of the building facade as follows:
i. Lobby doors and associated entries may be recessed a maximum depth of ten feet.
ii. Vehicular doors may be recessed a maximum depth of 20 feet.
iii. Other doors may be recessed a maximum depth of five feet.
6. Pedestrian entrances to all sidewalk-level uses with public or private street frontage:
a. Shall be architecturally articulated, face, be visible from, and be directly accessible from the sidewalk adjacent to such street.
b. When located along Memorial Drive, Martin Luther King Jr. Drive, Hill Street (south of Martin Luther King Jr. Drive), Cherokee Avenue, or Boulevard, shall face, be visible from, and be directly accessible from the sidewalk along one such street, with the exception of single-family and
two-family dwellings and multi-family buildings with no unit located above or below another residential unit.
c. The use of fire-escape, entrance-only and exit-only doors as primary entrances is
explicitly prohibited.
d. Having non-residential uses:
i. Shall remain unlocked during business hours.
ii. Shall be at-grade with the closest portion of the adjacent required sidewalk.
e. Having residential uses:
i. Shall be linked to the required sidewalk with a pedestrian walkway a minimum of four feet wide.
ii. All such buildings, except assisted living facilities, with more than four residential units that are adjacent to the required sidewalk shall have individual entrances to such units directly accessible from the adjacent sidewalk and shall open directly onto the adjacent sidewalk, park, plaza or terrace adjacent to the sidewalk unless existing topographic considerations render this requirement unreasonable. All pedestrian walkways providing such access shall
be perpendicular to the street, unless existing topographic considerations render this requirement unreasonable, and shall be permitted to share said walkway with one adjacent unit.
iii. Said buildings shall have porches or stoops or wheelchair access at each
sidewalk-level pedestrian entrance.
iv. All residential uses not located at sidewalk-level shall have pedestrian access to the sidewalk via a common lobby fronting and accessible from said sidewalk.
f. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five
foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit.
This provision shall not apply to singlefamily and two-family residential structures.
7. Fenestration requirements: Buildings shall provide either a storefront façade treatment or a residential façade treatment along all streetfronting sidewalk-levels which shall apply to all uses including parking decks, except churches and fire stations and have the following requirements:
a. Windows and door glass shall utilize clear glass or tinted glass. Tinted glass shall have a transmittance factor of 50
percent or greater and shall have a visible light reflectance factor of ten or less.
Painted glass, reflective glass or other similarly treated or opaque windows are
not permitted.
b. Fenestration, including entryways, shall be provided for a minimum horizontal
linear percentage for each façade specified below in subsection 16-18V.011(7)(c) and subsection 16-18V.011(7)(d).
c. Storefront façade treatment: Adjacent to Memorial Drive, Martin Luther King Jr.
Drive, or Capitol Avenue or other buildings on other streets having commercial uses at sidewalk-level, a storefront façade shall be required for a minimum of 65
percent of the horizontal length of the sidewalk-level façade per the following requirements (See Diagram 5):
i. The length of façade without intervening fenestration or entryways shall not exceed 20 horizontal linear feet.
ii. A minimum of 90 percent of the required fenestration shall allow visibility into habitable space for a minimum depth of ten feet from the
interior window pane. The remainder of provided fenestration shall allow visibility for a minimum depth of three feet measured similarly.
iii. Beginning at a point not higher than three feet above the adjacent sidewalk to a height no less than ten feet above the finished floor elevation when the finished floor elevation is less than three [feet] above the sidewalk.
iv. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation
when the finished floor elevation is three or more feet above the sidewalk.
v. From its base to a height not less than the height of the adjacent primary pedestrian entrance, fenestration described in subsection iii. and iv. above shall be a single piece of plate glass having a minimum width of two feet.
d. Residential façade treatment: Along all streets, except Memorial Drive, Martin
Luther King, Jr. Drive, Capitol Avenue, and George Street, a residential façade treatment shall be provided for sidewalklevel residential uses for a minimum of 25 percent of the length of the sidewalklevel façade with each façade being calculated independently, in addition to the following requirements:
i. Windows on each street frontage façade shall be a minimum three feet in height and substantially similar in size on all sidewalk-level façades.
ii. Equally sized vertical windows shall be arranged horizontally.
iii. Windowpanes shall be recessed a minimum two inches from the adjacent façade.
8. External storefront security grilles, gates and security doors: shall be fully retractable during business hours and shall permit visibility into the interior of protected space when in use.
External housing and shields for such systems shall be painted the same color as the frames of the storefront system they protect.
9. A street address number shall be located directly above or beside the primary building and business establishment entrances along the required sidewalk, shall be clearly visible from the sidewalk and shall be a minimum of six inches in height.
10. Awnings and canopies: Shall not encroach beyond the sidewalk clear zone.
11. Sidewalk arcades: Arcades shall be prohibited.
12. Fences and walls: Shall meet the following regulations:
a. For residential uses adjacent to the sidewalk: fences shall not exceed four feet in height when located between the primary building and the street.
b. For non-residential uses adjacent to the sidewalk: fences are prohibited when
located between the building and the sidewalk except where specifically authorized elsewhere in this chapter for outdoor dining.
c. For non-residential uses not adjacent to the sidewalk: Fences and walls located
between the primary building and the lot line and not exceeding six feet in height may be erected but shall not be permitted between the primary building and the street except as set forth below in
subsection 16-18V.011(12)(d).
d. No walls, except retaining walls, shall be located between the street and any building, with the exception of screening for authorized off-street loading areas.
e. Retaining walls located adjacent to a sidewalk along a public or private street shall not exceed a height of 36 inches and the combined height of a fence and retaining wall shall not exceed a height of six feet, unless existing topographic
considerations render this requirement unreasonable. Retaining walls shall not be finished with split-faced concrete or cinderblock. See subsection 16-29.001(25).
f. No chain link fence or similar elements shall be visible from any public plaza,
ground-level or sidewalk-level outdoor dining area or public right-of-way. No barbed or razor wire fence shall be permitted.
13. Associated vehicular services such as air pumps and car washes shall not be located between a building and the street.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06; Ord. No.
2026-05(26-O-1001), § 14, 2-25-26) Sec. 16-18V.012. Signage.
Refer to Section 16-28A, Sign Ordinance.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.013. Loading areas, dock
entrances, mechanical and accessory features.
1. Dumpsters and loading areas shall be paved with impervious materials and shall be screened so as not to be visible from any public plaza, ground-level or sidewalk-level outdoor dining area, public sidewalk, public right-of-way, private street or an adjacent R-1 through R-5, RLC, R-G, MR, PD-H or Grant Park Historic district. In addition,
all external dumpsters and loading areas serving residential uses shall be enclosed with opaque walls six feet in height.
2. Loading dock entrances for non-residential uses shall be screened so that loading docks and related activity are not visible from the public right-of-way, private street or an adjacent R-1 through R-5, RLC, R-G, MR, PD-H or Grant Park Historic district.
3. Building mechanical and accessory features (including satellite dishes):
a. Shall be located to the side, rear, or roof of the principal structure and be in the location of least visibility from the public right-of-way, private street or an adjacent R-1 through R-5, RLC, R-G, MR, PD-H or
Grant Park Historic district. Screening with plant or fence materials shall be required if the equipment is otherwise visible.
b. When located on rooftops shall be incorporated in the design of the building and screened with building materials
similar to the building.
c. Shall not be permitted between the building and any public street.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.014. Off-street loading requirements.
The off-street loading requirements for this district are as shown in the table of loading requirements, section 16-28.015, off-street loading requirements.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06; Ord. No.
2019-09(18-O-1581), § 4.F, 1-31-19) Sec. 16-18V.015. Driveway curb cuts, driveways and parking structures.
1. Driveway curb cuts:
a. Shall be a maximum of 24 feet for twoway entrances and 12 feet for one-way entrances, unless otherwise permitted by the commissioner of public works.
b. Shall not be permitted on any street that functions at the location on the right-ofway in question as an arterial street or collector street when access may be
provided from a local street with the exception of hotels and hospitals.
c. All sidewalk paving materials shall be continued across any intervening driveway curb cut at the same prevailing grade
and cross slope as the adjacent sidewalk clear zone.
d. Shall have a band of textured concrete adjacent to the street which is in-line
and equal in width to the street furniture zone and shall have a textured band of
concrete adjacent to the back of that sidewalk and in-line with the supplemental zone of a minimum width of five feet.
e. Maximum permitted number of driveway curb cuts for each development, subject to the provisions of subsection 16-25.002(3):
i. Developments with only one street frontage, which is less than 300 feet in length: One.
ii. Developments with only one street frontage, which is greater than or equal to 300 feet in length: Two.
iii. Developments with more than one street frontage: One located on each street frontage, with the exceptions as indicated in subsection 16-18V.015(1)(b).
iv. For the purposes of this section, two curb cuts serving two one-way
driveways shall only be counted as one curb cut.
2. Driveways:
a. Driveways or circular drives, except to reach the side yard or rear yard or an
on-site parking facility, are not permitted between the sidewalk and a building,
and shall be perpendicular to any adjacent street with the exception of hotels,
hospitals, childcare centers, kindergartens and special schools, subject to provisions in subsection 16-25.002(3).
b. Driveways that are outside the lot boundaries shall be permitted provided they are directly connected to a public street, subject to provisions in subsection 16-25.002(3).
c. All contiguous ground-floor residential units shall share one common drive,
located in rear yards or side yards without street frontage, to serve garages and
parking areas.
d. Independent driveways are not required when access is provided to a private
alley. For single and two-family dwellings independent driveways are not required.
e. Notwithstanding the provisions of subsection 16-28.006(10), the director of the bureau of planning may authorize a
common or joint driveway when adjacent lots have direct vehicular access to a street or a driveway from a private street which functions as a public street based on traffic considerations when a perpetual easement agreement is agreed upon by
all affected property owners and a copy of such agreement is provided to the bureau of planning.
3. Parking structures, in addition to section 16-28.028, either principal or accessory use:
when located immediately adjacent to any public right-of-way, public park, private street or adjacent R-1 through R-5, RLC, R-G, MR, PD-H or Grant Park Historic district:
a. Shall have the appearance of a horizontal storied building on all levels. Said deck shall have an appearance similar to that of the adjoining or attached residential, commercial or mixed-use structure.
c. See section 16-18V.016 for additional lighting requirements.
d. Shall meet the active-use and façade treatment requirements as applicable in section 16-18V.011 unless topographic considerations render this requirement unreasonable. In such case, a continuous minimum five feet wide landscaped strip
shall be provided between the structure and the public sidewalk, except at ingress and egress points into the structure.
Said landscaped strip shall be planted with street trees spaced a maximum distance of 20 feet on center, which shall also meet the tree requirements in subsection 16-18V.009(5). The landscape strip shall also be planted with evergreen
ground cover such as mondo grass, liriope spicata, ivy or evergreen shrubs with a maximum mature height of 24 inches.
All plantings, planting replacement and planting removal shall be approved by the city arborist.
e. Shall provide a continuous landscaped strip between the structure and property line located immediately adjacent to any public park, private street or adjacent
R-1 through R-5, RLC, R-G, MR, PD-H or Grant Park Historic district to be planted as indicated above in subsection
16-18V.015(3)(d).
4. All developments, including parking decks, shall have walkways a minimum width of four feet connecting ground level parking to the public sidewalks and to all building entrances.
5. Entrances to garages and carports that serve a single residential unit, and which are located less than 20 feet behind the façade of the principal structure, shall face the rear yard or a side yard which has no street frontage.
6. Drop-off lanes: Where on-street parking is provided, certain parking spaces may be utilized as drop-off spaces, when permitted by the commissioner of transportation. Drop-off spaces or lanes are otherwise prohibited.
7. Drive-through service windows, drive-in facilities and associated queuing areas are permitted only when completely enclosed within a building or parking structure and subject to the active use requirement of subsection 16-18V.011(2) except at ingress and egress points. Such facilities shall also be limited to one drive-through or drive-in facility and one queuing lane. Drivethrough facilities for eating and drinking establishments are not permitted.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06; Ord. No.
2008-67(08-O-0196), § 13, 7-21-08; Ord. No. 2020- 33(20-O-1381), § 40, 6-23-20)
Sec. 16-18V.016. Lighting, security, and maintenance requirements.
1. All lighting, including all parking decks and lots, loading areas, and lit canopies, shall reduce light spillage onto adjacent residentially used properties by providing cutoff luminaries that have a maximum 90 degree illumination.
2. All lighting that up-lights trees, buildings or other elements, shall be located a minimum height of eight feet above the sidewalk, driveway or pedestrian area when not located within completely landscaped areas.
3. All parking facilities shall be maintained in a clean, safe and sanitary condition. Parking spaces and driving lanes shall be clearly defined and maintained as such. Parking lots shall not be operated when any damage impairs the drivability of the parking lot. See Section 16-28.014 for additional requirements.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.017. Minimum landscaping
requirements for surface parking lots.
The requirements of City of Atlanta Code of Ordinances, Chapter 158 Vegetation, Article II Tree Protection, Section 30 Parking Lot Requirements shall apply to this district in addition to the street tree planting requirements, with additional requirements as follows:
1. Said surface parking lot requirements shall apply to all lots regardless of size.
2. Existing parking lots shall not be required to reduce the number of parking spaces
by more than three percent as a result of implementing the following surface parking lot landscaping regulations.
a. All parking bays shall be terminated with a landscape strip a minimum width of five feet and equal to the length of the parking bay.
b. All required landscaped areas shall be planted with evergreen groundcover or shrubs with a maximum mature height of 30 inches; and
c. All required landscaped buffer strips, regardless of length, shall have a
minimum of one tree planted per 30 feet of length with a minimum caliper of two and one-half inches.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.018. Off-street bicycle parking and showering requirements.
See section 16-28.014(6), Bicycle parking requirements.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06; Ord. No.
2019-09(18-O-1581), § 12, 1-31-19) Sec. 16-18V.019. Off-street parking requirements.
1. Off-street surface parking lots:
a. Shall not be located between a building and the street without an intervening
building with the exception of the redevelopment of existing structures in Subarea 1.
b. Parking facilities shall be accessory to a permitted principal use only, provided
that parking spaces serving another principal permitted use may use such facility for shared parking during nonnormal business hours by compliance with the SPI-22 Memorial Drive/Oakland
Cemetery: Parking Table.
2. No portion of any parcel on which a building has been demolished, destroyed, or otherwise removed after the adoption of this ordinance shall be utilized for an independent primary park-for-hire surface parking lot.
3. The provisions of subsection 16-28.008(7) shall apply and are incorporated herein, the (following parking requirements shall apply as specified in the Memorial Drive/Oakland
Cemetery: Parking Table.
4. Office uses, additional requirements:
a. All office developments over 100,000 square feet shall reserve and designate at least five percent of the-parking spaces "Carpool Only." Carpool spaces shall be
used only by carpool vehicles in which at least two of the persons are employees or tenants of the building. Such spaces
shall be located near the building's employee entrance or other preferable locations within the employee parking areas as approved by the commissioner of transportation; and
b. All new parking structures shall be built to accommodate vanpool access at entry
level. The minimum ceiling height for vanpools is eight feet two inches.
SPI-22 MEMORIAL DRIVE/OAKLAND CEMETERY: PARKING TABLE Use Minimum Parking Requirement Maximum Parking Allowed Banks/Financial Institutions
Business/Commercial Schools Clubs & Lodges Printing Shops
5.0 spaces per 1,000 sq. ft. 12.5 spaces per 1,000 sq. ft.
Childcare Centers Hotels and Motels 1.67 spaces per 1,000 sq. ft. 5.0 spaces per 1,000 sq. ft.
Schools and colleges Churches, recreation or community centers and other places of assembly
•1.0 space for each four fixed eats (with 18 inches if bench length counted as one seat);
or
1.0 space for each 35 sq. ft. of enclosed floor area for the accommodation of movable seats in the largest assembly room, whichever
is greater.
•Public or private elementary or middle school: 1.0 space per classroom.
•High school: 2.0 spaces per classroom.
Colleges and universities: 4.0 spaces per classroom.
1.5 spaces for each four fixed seats (with 18 inches if bench length counted as one seat);
or
2.0 spaces for each 35 sq. ft. of enclosed floor area for the accommodation of movable seats in the largest assembly room, whichever
is greater.
+ •Public or private elementary or middle school; 2.0 spaces per classroom.
•High school: 4.0 spaces per classroom.
•Colleges and universities: 8.0 spaces per classroom.
Dormitories, Fraternities and Sororities
0.5 spaces for each bedroom +2.5 spaces per 1,000 sq. ft. common areas.
1.0 space per bedroom up to two bedrooms + 1 /2 space for each bedroom unit three or more + 5.0 spaces per 1,000 sq. ft. common areas.
Eating and Drinking Establishments •Indoor Dining or •Covered Outdoor Dining •Subareas 1 & 2: 2.5 spaces per 1,000 sq. ft.
•Subareas 3 & 4: 4.0 spaces per 1,000 sq. ft. or 2.5 spaces per 1,000 square feet when located in a mixed-use building.
7.0 spaces per 1,000 sq. ft.
Use Minimum Parking Requirement Maximum Parking Allowed Eating and Drinking
Establishments •Uncovered Outdoor Dining •Subareas 1 & 2: 1.5 spaces per 1,000 sq. ft. or none.2 •Subareas 3 & 4: 3.0 spaces per 1,000 sq. ft. or 1.5 spaces per 1,000 square feet when located in a mixed-use building or none.2
7.0 spaces per 1,000 sq. ft.
Nursing homes, personal care homes, assisted living facilities, and rehabilitation centers
1.0 space per four beds 2.5 spaces per four beds Office (also subject to Section
16-18V.019(4)) •Subareas 1, 2, & 3: None •Subarea 4: 3.0 spaces per 1,000 sq. ft.
•3.5 spaces per 1,000 sq. ft. within Transit Station Area •4.0 spaces per 1,000 sq. ft.
outside Transit Station Area Residential None
1.0 space per bedroom up to two bedrooms + 1 /2 space for each bedroom unit three or more + 1 /3 space per unit guest parking, not to exceed 10 spaces.
Retail 1.67 spaces per 1,000 sq. ft. 5.0 spaces per 1,000 sq. ft.
All other non-residential uses 1.67 spaces per 1,000 sq. ft. 4.0 spaces per 1,000 sq. ft.
1 Minimum parking requirements may be reduced provided a shared parking arrangement subject to 16-18V.019(5).
2 There shall be no minimum parking requirement when uncovered outdoor dining is 25% or less than the total gross floor area of the said eating and drinking establishment.
_______________________________________________________________________________________________
5. Shared or off-site parking arrangements may be permitted by the Director of the Bureau of Planning subject to the following criteria:
a. The arrangement shall avoid conflicting parking demands and provide for safe
pedestrian circulation and access;
b. All shared parking spaces shall be signed;
c. An applicant shall submit the following:
i. A to-scale map indicating location of proposed parking spaces;
ii. Hours of business operation of nonresidential parking users;
iii. Written consent of property owners agreeing to the shared parking arrangement;
iv. Copies of parking leases. Renewed leases shall be filed with the Bureau of Planning. Lapse of a required lease agreement shall terminate the Special Administrative permit for shared parking.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06; Ord. No.
2020-33(20-O-1381), § 41, 6-23-20) Sec. 16-18V.020. Membership in transportation management associations and transportation management plans.
Any development that has an office component greater than 200,000 square feet of total gross leasable floor area of space shall become a member of an existing Transportation Management Association (TMA) which provides service to the area or shall provide a Transportation Management Plan (TMP) with the criteria listed below. The bureau of buildings shall not issue occupancy permits for any development in this district until such time as the developer or leasing agent for each of the components has submitted to the director of the bureau of planZONING § 16-18V.020 ning, written confirmation of TMA membership or has submitted a Transportation Management Plan. The local TMA may assist with the preparation of the TMP.
The TMP shall contain strategies to reduce single occupancy vehicle trips generated by the project and shall be based on an annual commute mode survey. Said survey shall be based on a continuous five-day workweek for all estimated employees arriving at the work site and for all residents leaving the residential site between 6:00 a.m. and 10:00 a.m., Monday through Friday.
Based upon the survey information, the employer and residential manager shall develop a TMP which shall include any of the following:
1. Commute alternatives:
a. Incentives for public transit ridership such as transit cards;
b. Carpooling and vanpooling;
c. Commuter bicycling and walking programs;
d. Alternative work hours.
2. Transportation demand strategies:
a. Improvements to alternative modes such as vanpooling;
b. Financial incentives given to employees who use commute alternatives;
c. Parking management programs;
d. Commute alternatives information and marketing;
e. Shared parking arrangements;
f. Provision for a mixture of uses onsite;
g. Pedestrian links to adjacent uses.
3. A program to promote and maintain employee participation in carpooling, vanpooling, and use of mass transit, including a method of monitoring the number of ride
sharers and their travel patterns.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.021. Pedestrian bridges and tunnels.
Pedestrian bridges and tunnels, buildings, parking structures and privately owned vehicular bridges and tunnels shall be allowed when located above or below railway right-of-way or interstate highways, however, they shall otherwise be prohibited when located above or below public streets.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.022. Specific regulations for Subarea 1—MLK lofts.
Reserved.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.023. Specific regulations for Subarea 2—Capitol-Oakland corridor.
Reserved.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.024. Specific regulations for Subarea 3—Capitol Gateway.
Reserved.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.025. Specific regulations for Subarea 4—Grant Park North.
1. All required sidewalks:
a. Shall be provided consistent with a sidewalk plan approved by the Grant Park Neighborhood Association and the Bureau of Planning; or
b. The original layout, pattern and paving materials of sidewalks and curbs shall be retained for that block.
2. EIFS (External Insulating Finishing System) is prohibited for any exterior wall surface.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.026. Specific regulations for Subarea 5—Memorial Green.
Reserved.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06) Sec. 16-18V.027. Illustrative diagrams.
The illustrations contained within this section are graphic depictions of several of the requirements of this Chapter. Unless otherwise indicated, each diagram is intended to specifically illustrate the indicated Section; all suggestions of architectural style, on-street parking, and tree shape requirements do not constitute a requirement of this Chapter.
DIAGRAMS 1a, 1b (Ord. No. 2006-96, § 1(Att. A), 12-6-06)
DIAGRAMS 2, 3
DIAGRAMS 4, 5
CHAPTER 18X. SPI-24 GARDEN HILLS
NEIGHBORHOOD DISTRICT
REGULATIONS
Sec. 16-18X.001. Scope of provision.
The regulations set forth in this chapter, or set forth elsewhere in this part, when referred to in this chapter, are the regulations in the SPI-24 Garden Hills Neighborhood District.
(Ord. No. 2020-19(19-O-1701), § 1(Exh. A), 4-29- 20)
Sec. 16-18X.002. Statement of intent.
The intent of this chapter is establishing the SPI-24 Garden Hills Neighborhood District is as follows:
(1) To preserve and protect the existing lots of record within the Garden Hills
Neighborhood from development which is not in accord with prevailing neighborhood patterns.
(2) To amend the language in section 16-28.007(4)(b) of the Atlanta Zoning Ordinance within the area so designated on the attached map identified as Exhibit B.
(Ord. No. 2020-19(19-O-1701), § 1(Exh. A), 4-29- 20)
Sec. 16-18X.003. Regulations.
The regulation of "regular corner lots" (16- 28.007(4)(b) of the Atlanta Zoning Ordinance) is hereby modified as follows for the area so designated on the attached map identified as Exhibit B:
(b) On regular corner lots: The halfdepth front yard for a regular corner lot shall be construed as the average front
yard of the established building pattern on the block face between intersecting
streets. If a building pattern has not been established, then the half-depth front yard shall be according to the requirements of the zoning district.
(Ord. No. 2020-19(19-O-1701), § 1(Exh. A), 4-29- 20)
CHAPTER 18Y. SPI-25 TUXEDO PARK
NEIGHBORHOOD DISTRICT
REGULATIONS
Sec. 16-18Y.001. Scope of provisions.
The regulations set forth in this chapter, or set forth elsewhere in this part, when referred to in this chapter, are the regulations in the SPI-25 Tuxedo Park Neighborhood District. Whenever the following regulations conflict with provisions of Part III Code of Ordinances - Land Development Code Part 15 - Land Subdivision Ordinance or Part 16 - Atlanta Zoning Ordinance, the more stringent regulation shall apply.
(Ord. No. 2023-11(23-O-1011), § 1(Exh. A), 3-29- 23)
Sec. 16-18Y.002. Statement of intent.
The intent of this chapter is establishing the SPI-25 Tuxedo Park Neighborhood District is as follows:
(1) To preserve and protect existing general landscaping features and existing spatial relationships between the buildings and
public streets, and between buildings;
(2) To ensure that new lots reflect and reinforce the exceptional park-like features established in the original planning and platting of Tuxedo Park;
(3) To reinforce the lot pattern of long, rectangular lots and deep setbacks of the residences; and
(4) Maintain the spatial organization of large open spaces between residences and public streets.
(Ord. No. 2023-11(23-O-1011), § 1(Exh. A), 3-29- 23)
Sec. 16-18Y.003. Regulations.
(1) Subdivision requirements.
a. The Tuxedo Park neighborhood, as defined by the City of Atlanta, shall be considered a historic neighborhood for the purposes of Part 15 of the Land Subdivision
Ordinance. All subdivisions within this district shall not be subject to section 15-08.002(a)(2) and section 15-008(5)(d) of the Land Subdivision Ordinance, but
shall meet the following requirements in addition to all other requirements of the Land Subdivision Ordinance:
i. New subdivisions shall not create new public streets.
ii. All new lots shall be no wider than the widest lot on the same side of the street between the two closest intersections.
iii. All new lots zoned R-3 shall be no narrower than the narrowest lot on the same side of the street between the two closest intersections, or 100 feet, whichever is greater.
iv. All new lots zoned R-2 shall be no narrower than the narrowest lot on the same side of the street between the two closest intersections, or 150 feet, whichever is greater.
v. All new lots shall conform to the range of lot depths established by the lots on the same side of the street between the two closest intersections. However, no new lot shall be created unless it contains a depth that is at least twice the length of its width;
b. All new lots shall be oriented so that the shortest side of the lot faces the street.
(2) Development controls.
a. Setbacks: